Thermodynamics of mechanical transduction of surface confined receptor/ligand reactions

被引:22
作者
Bergese, Paolo
Oliviero, Giulio
Alessandri, Ivano
Depero, Laura E.
机构
[1] Univ Brescia, INSTM, Chem Technol Lab, I-25123 Brescia, Italy
[2] LATEMAR Unit Brescia, Brescia, Italy
关键词
thermodynamics; interfaces; chemomecanical transduction; microcantilevers;
D O I
10.1016/j.jcis.2007.08.048
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Chemomechanics of surface stress is discussed in terms of interfacial thermodynamics. In the first section the paper shows how to quantitatively describe the chemical equilibrium of a receptor/ligand binding reaction confined at a solid-liquid interface and how the overall work of the reaction splits into chemical and surface work, that appears as a surface pressure. In the second section this thermodynamic model is applied to describe the experimental results of microcantilever bending induced by DNA hybridization occurring onto one of its faces. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:1017 / 1022
页数:6
相关论文
共 39 条
  • [21] Cantilever-based optical deflection assay for discrimination of DNA single-nucleotide mismatches
    Hansen, KM
    Ji, HF
    Wu, GH
    Datar, R
    Cote, R
    Majumdar, A
    Thundat, T
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (07) : 1567 - 1571
  • [22] Label free analysis of transcription factors using microcantilever arrays
    Huber, F
    Hegner, M
    Gerber, C
    Güntherodt, HJ
    Lang, HP
    [J]. BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) : 1599 - 1605
  • [23] KIBBE WA, 1998, P NATL ACAD SCI USA, V95, P1460
  • [24] Monitoring the formation of self-assembled monolayers of alkanedithiols using a micromechanical cantilever sensor
    Kohale, Swapnil
    Molina, Sara M.
    Weeks, Brandon L.
    Khare, Rajesh
    Hope-Weeks, Louisa J.
    [J]. LANGMUIR, 2007, 23 (03) : 1258 - 1263
  • [25] Using microcantilever deflection to detect HIV-1 envelope glycoprotein gp 120
    Lam, Yee
    Abu-Lail, Nehal I.
    Alam, Munir S.
    Zauscher, Stefan
    [J]. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2006, 2 (04) : 222 - 229
  • [26] PHASE RULE FOR CAPILLARY SYSTEMS
    LI, D
    NEUMANN, AW
    [J]. ADVANCES IN COLLOID AND INTERFACE SCIENCE, 1994, 49 : 147 - 195
  • [27] Ultra-sensitive NEMS-based cantilevers for sensing, scanned probe and very high-frequency applications
    Li, Mo
    Tang, H. X.
    Roukes, M. L.
    [J]. NATURE NANOTECHNOLOGY, 2007, 2 (02) : 114 - 120
  • [28] Flexoelectric origin of nanomechanic deflection in DNA-microcantilever system
    Liu, F
    Zhang, Y
    Ou-Yang, ZC
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) : 655 - 660
  • [29] Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever array
    McKendry, R
    Zhang, JY
    Arntz, Y
    Strunz, T
    Hegner, M
    Lang, HP
    Baller, MK
    Certa, U
    Meyer, E
    Güntherodt, HJ
    Gerber, C
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (15) : 9783 - 9788
  • [30] Measuring surface-induced conformational changes in proteins
    Moulin, AM
    O'Shea, SJ
    Badley, RA
    Doyle, P
    Welland, ME
    [J]. LANGMUIR, 1999, 15 (26) : 8776 - 8779