Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses - Prospective evaluation

被引:111
作者
Kershner, RM [1 ]
机构
[1] Eye Laser Ctr, Tucson, AZ 85704 USA
关键词
D O I
10.1016/S0886-3350(03)00523-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the effects of an aspheric intraocular lens (IOL) (Tecnis Z-9000, Pharmacia Corp.) with those of conventional silicone (AA4207VF, Staar Surgical) and acrylic (AcrySof((R)) SA60AT, Alcon Surgical) lenses on retinal imaging and functional visual performance. Setting: Eye Laser Center, Tucson, Arizona, USA. Methods: In this prospective study, 221 eyes of 156 patients were randomly assigned to receive 1 of 3 IOLs. Visual acuity was measured preoperatively and 1 day, 1 and 3 weeks, and 1, 3, and 6 months postoperatively. Fundus photography and photopic and mesopic functional acuity contrast testing were performed preoperatively and 3 months postoperatively. Results: The differences in the preoperative and postoperative spherical and astigmatic refractive errors and best corrected visual acuity among groups were not statistically significant. The postoperative uncorrected visual acuity was best in the aspheric group in the first month. Functional acuity contrast testing showed the aspheric IOL group had a 38% to 47% increase in photopic vision, 38% in photopic with glare, 43% to 100% in mesopic, and 9% to 100% in mesopic with glare. There was no increase in photopic vision in the acrylic group but increases of 38% in photopic with glare, 25% to 50% in mesopic, and 36% to 50% in mesopic with glare. The spherical silicone IOL group had no increase in contrast testing from preoperatively. Digital analysis of retinal imaging showed increased threshold luminance levels in the aspheric group (range 116 to 208 cd/m(2)) and a 4-fold increase in image contrast. Conclusions: All 3 IOLs led to improved visual acuity after cataract surgery. The aspheric IOL provided a significant improvement in retinal image contrast and visual performance measured by visual acuity and functional acuity contrast testing. This improvement was greatest in night vision and night vision with glare compared to the performance of conventional spherical silicone and acrylic IOLs. (C) 2003 ASCRS and ESCRS.
引用
收藏
页码:1684 / 1694
页数:11
相关论文
共 29 条
[1]   Contribution of the cornea and internal surfaces to the change of ocular aberrations with age [J].
Artal, P ;
Berrio, E ;
Guirao, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (01) :137-143
[2]   EFFECTS OF AGING IN RETINAL IMAGE QUALITY [J].
ARTAL, P ;
FERRO, M ;
MIRANDA, I ;
NAVARRO, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (07) :1656-1662
[3]   THROUGH FOCUS IMAGE QUALITY OF EYES IMPLANTED WITH MONOFOCAL AND MULTIFOCAL INTRAOCULAR LENSES [J].
ARTAL, P ;
MARCOS, S ;
NAVARRO, R ;
MIRANDA, I ;
FERRO, M .
OPTICAL ENGINEERING, 1995, 34 (03) :772-779
[4]   Corneal and total optical in a unilateral aphakic aberrations patient [J].
Barbero, S ;
Marcos, S ;
Merayo-Lloves, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (09) :1594-1600
[5]   CONTRIBUTION OF CRYSTALLINE LENS TO SPHERICAL ABERRATION OF EYE [J].
ELHAGE, SG ;
BERNY, F .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1973, 63 (02) :205-211
[6]  
ELMAGHRABY A, 1993, FOLDABLE INTRAOCULAR, P3
[7]   CORTICAL CLEAVING HYDRODISSECTION [J].
FINE, IH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (05) :508-512
[8]  
GILLS JP, 1990, SMALL INCISION CATAR
[9]  
Ginsburg AP, 1996, FUNCTIONAL ASSESSMEN, P77
[10]  
GRABOW HB, 1993, FOLDABLE INTRAOCULAR, P75