Two coherent frequency combs are used to measure the full complex response of a sample in a configuration analogous to a dispersive Fourier transform spectrometer, infrared time domain spectrometer, or a multiheterodyne laser spectrometer. This dual-comb spectrometer retains the frequency accuracy and resolution of the reference underlying the stabilized combs. We discuss the specific design of our coherent dual-comb spectrometer and demonstrate the potential of this technique by measuring the overtone vibration of hydrogen cyanide, centered at 194 THz (1545 nm). We measure the fully normalized, complex response of the gas over a 9 THz bandwidth at 220 MHz frequency resolution yielding 41,000 resolution elements. The average spectral signal-to-noise ratio (SNR) over the 9 THz bandwidth is 2500 for both the magnitude and phase of the measured spectral response and the peak SNR is 4000. This peak SNR corresponds to a fractional absorption sensitivity of 0.05% and a phase sensitivity of 250 microradians. As the spectral coverage of combs expands, coherent dual-comb spectroscopy could provide high-frequency accuracy and resolution measurements of a complex sample response across a range of spectral regions. Work of U. S. government, not subject to copyright.
引用
收藏
页数:13
相关论文
共 69 条
[1]  
Abramowitz M., 1964, HDB MATH FUNCTIONS F
[2]   Cavity-Enhanced Direct Frequency Comb Spectroscopy: Technology and Applications [J].
Adler, Florian ;
Thorpe, Michael J. ;
Cossel, Kevin C. ;
Ye, Jun .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 3, 2010, 3 :175-205
[3]   Phase-stabilized, 1.5 W frequency comb at 2.8-4.8 μm [J].
Adler, Florian ;
Cossel, Kevin C. ;
Thorpe, Michael J. ;
Hartl, Ingmar ;
Fermann, Martin E. ;
Ye, Jun .
OPTICS LETTERS, 2009, 34 (09) :1330-1332
[4]   High-resolution absorption coefficient and refractive index spectra of carbon monoxide gas at millimeter and submillimeter wave-lengths [J].
Almoayed, Nawaf N. ;
Afsar, Mohammed N. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2006, 55 (04) :1033-1037
[5]   Ultrafast time-domain spectroscopy based on high-speed asynchronous optical sampling [J].
Bartels, A. ;
Cerna, R. ;
Kistner, C. ;
Thoma, A. ;
Hudert, F. ;
Janke, C. ;
Dekorsy, T. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (03)
[6]   Molecular structure and orientation: Concepts from femtosecond dynamics [J].
Baskin, JS ;
Zewail, AH .
JOURNAL OF PHYSICAL CHEMISTRY A, 2001, 105 (15) :3680-3692
[7]   High-performance, vibration-immune, fiber-laser frequency comb [J].
Baumann, Esther ;
Giorgetta, Fabrizio R. ;
Nicholson, Jetlrey W. ;
Swann, William C. ;
Coddington, Ian ;
Newbury, Nathan R. .
OPTICS LETTERS, 2009, 34 (05) :638-640
[8]  
Bell R.J., 1972, INTRO FOURIER TRANSF
[9]   Cavity-enhanced dual-comb spectroscopy [J].
Bernhardt, Birgitta ;
Ozawa, Akira ;
Jacquet, Patrick ;
Jacquey, Marion ;
Kobayashi, Yohei ;
Udem, Thomas ;
Holzwarth, Ronald ;
Guelachvili, Guy ;
Haensch, Theodor W. ;
Picque, Nathalie .
NATURE PHOTONICS, 2010, 4 (01) :55-57
[10]  
BIRCH JR, 1987, MIKROCHIM ACTA, V3, P105, DOI 10.1007/BF01201686