Lung diffusing capacity for nitric oxide and carbon monoxide

被引:25
作者
Dressel, Holger [1 ]
Filser, Laura [1 ]
Fischer, Rainald [2 ]
de la Motte, Dorothea [1 ]
Steinhaeusser, Werner [3 ]
Huber, Rudolf M. [2 ]
Nowak, Dennis [1 ]
Joerres, Rudolf A. [1 ]
机构
[1] Univ Munich, Inst & Outpatient Clin Occupat Social & Environm, D-80336 Munich, Germany
[2] Univ Munich, Med Klin Innenstadt, Dept Pneumol, D-80336 Munich, Germany
[3] Viasys Healthcare GmbH, Wurzburg, Germany
关键词
airway obstruction; carbon monoxide; cystic fibrosis; lung diffusing capacity; nitric oxide; variability;
D O I
10.1378/chest.07-2388
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The combined measurement of diffusing capacity of the lung for nitric oxide (DLNO) and diffusing capacity of the lung for carbon monoxide (DLCO) is a simple, noninvasive tool, but methodologic factors might influence results and reproducibility. We thus quantified the influence of breath-hold time on DLCO and DLNO in subjects with or without airway disease. Methods: Simultaneous single-breath measurements of DLCo and DLNO Were performed in 10 patients with cystic fibrosis (CF) [mean +/- SD age, 33 +/- 9 years; FEV1, 69 +/- 28% of predicted] and 10 healthy subjects (age, 31 +/- 9 years; FEV1, 108 +/- 8% of predicted), using the Masterscreen PFT (Viasys/Jaeger; Hochberg, Germany), With 45 ppm of inspired nitric oxide (NO), and breath-hold times of 4 s, 6 s, 8 s, and 10 s. The last two of three consecutive measurements were used for analysis. Results: in healthy subjects but not patients With CF, DLNO, and DLCO differed significantly (p < 0.05 each) between breath-hold times. Differences primarily occurred at 4 s and 10 s, while at 6 s and 8 s alveolar volume (VA), DLNO, DLCO, and DLNO/DLCO were similar. Variability of consecutive measurements (either three or the last two measurements) did not depend on breath-hold time. At 8 s, mean variabilities of DLNO and DLCO in healthy subjects were 4.9% and 2.5%, respectively, and 4.2% and 3.2% at 6 s. At 8 s, mean variabilities of DLNO and DLCO in CF patients were 4.4% and 1.9%, and 7.4% and 3.3% at 6 s. Conclusions: Single-breath determinations of DLNO and DLCO showed no difference between breath-hold times of 6 s and 8 s in subjects With or Without airway obstruction, and reproducibility was acceptable. Standardization of breath-hold time for DLNO measurements seems important for clinical and research comparisons.
引用
收藏
页码:1149 / 1154
页数:6
相关论文
共 20 条
[1]   Steady-state measurement of NO and CO lung diffusing capacity on moderate exercise in men [J].
Borland, C ;
Mist, B ;
Zammit, M ;
Vuylsteke, A .
JOURNAL OF APPLIED PHYSIOLOGY, 2001, 90 (02) :538-544
[2]   Reduction of pulmonary capillary blood volume in patients with severe unexplained pulmonary hypertension [J].
Borland, C ;
Cox, Y ;
Higenbottam, T .
THORAX, 1996, 51 (08) :855-856
[3]  
BORLAND C, 1983, CLIN SCI, V65, P37
[4]   EFFECT OF VARYING ALVEOLAR OXYGEN PARTIAL-PRESSURE ON DIFFUSING-CAPACITY FOR NITRIC-OXIDE AND CARBON-MONOXIDE, MEMBRANE DIFFUSING-CAPACITY AND LUNG CAPILLARY BLOOD-VOLUME [J].
BORLAND, CDR ;
COX, Y .
CLINICAL SCIENCE, 1991, 81 (06) :759-765
[5]   Deciphering the nitric oxide to carbon monoxide lung transfer ratio:: physiological implications [J].
Glenet, Stéphane N. ;
De Bisschop, Claire ;
Vargas, Frederic ;
Guenard, Hervé J. P. .
JOURNAL OF PHYSIOLOGY-LONDON, 2007, 582 (02) :767-775
[6]   Membrane conductance in trained and untrained subjects using either steady state or single breath measurements of NO transfer [J].
Glenet, Stephane N. ;
de Bisschop, Claire M. M. ;
Dridi, Rim ;
Guenard, Herve J. P. .
NITRIC OXIDE-BIOLOGY AND CHEMISTRY, 2006, 15 (03) :199-208
[7]   EFFECT OF BREATH-HOLD TIME ON DLCO(SB) IN PATIENTS WITH AIRWAY-OBSTRUCTION [J].
GRAHAM, BL ;
MINK, JT ;
COTTON, DJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (04) :1319-1325
[8]   DETERMINATION OF LUNG CAPILLARY BLOOD-VOLUME AND MEMBRANE DIFFUSING-CAPACITY IN MAN BY THE MEASUREMENTS OF NO AND CO TRANSFER [J].
GUENARD, H ;
VARENE, N ;
VAIDA, P .
RESPIRATION PHYSIOLOGY, 1987, 70 (01) :113-120
[9]   Standardisation of the single-breath determination of carbon monoxide uptake in the lung [J].
MacIntyre, N ;
Crapo, RO ;
Viegi, G ;
Johnson, DC ;
van der Grinten, CPM ;
Brusasco, V ;
Burgos, F ;
Casaburi, R ;
Coates, A ;
Enright, P ;
Gustafsson, P ;
Hankinson, J ;
Jensen, R ;
McKay, R ;
Miller, MR ;
Navajas, D ;
Pedersen, OF ;
Pellegrino, R ;
Wanger, J .
EUROPEAN RESPIRATORY JOURNAL, 2005, 26 (04) :720-735
[10]   DCO AT VARIOUS BREATH-HOLDING TIMES - COMPARISON IN PATIENTS WITH CHRONIC BRONCHIAL-ASTHMA AND EMPHYSEMA [J].
MAGNUSSEN, H ;
HOLLE, JP ;
HARTMANN, V ;
SCHOENEN, JD .
RESPIRATION, 1979, 37 (04) :177-184