Reliability and accuracy of MRI scanogram in the evaluation of limb length discrepancy

被引:33
作者
Leitzes, AH
Potter, HG
Amaral, T
Marx, RG
Lyman, S
Widmann, RE
机构
[1] Cornell Univ, Hosp Special Surg, Weill Med Coll, New York, NY 10021 USA
[2] Cornell Univ, Hosp Special Surg, Weill Med Coll, Dept Radiol, New York, NY 10021 USA
[3] Montefiore Hosp, Dept Pediat Orthopaed, Bronx, NY USA
[4] Cornell Univ, Hosp Special Surg, Weill Med Coll, Foster Ctr Clin Outcome Res, New York, NY 10021 USA
[5] Cornell Univ, Hosp Special Surg, Weill Med Coll, Dept Pediat Orthopaed Surg, New York, NY 10021 USA
关键词
limb length discrepancy; radiographic scanogram; CT scanogram;
D O I
10.1097/01.bpo.0000173246.12184.a5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to compare MRI scanogram with traditional radiographic methods for measurement of limb length. The authors hypothesized that MRI scanogram would be as reliable and accurate as radiographic scanogram in measurement of limb length without exposing patients to ionizing radiation. Twelve cadaveric femurs were measured using AP conventional radiographic scanogram, CT scanogram, MRI scanogram, and electronic caliper. Three orthopaedists performed two separate measurements using each technique. Intraobserver and interobserver variability was assessed for each of the three radiographic techniques. Accuracy was assessed by comparison of radiographic measurements to electronic caliper measurements of femur length. The reliability of all three radiographic limb length measurement techniques was excellent (ICC > 0.99). The accuracy of plain radiographic scanogram was slightly superior to CT scanogram and MRI scanogram. The mean absolute differences for radiographic, CT, and MRI scanograms compared with the gold standard, direct caliper measurement, were 0.52 mm, 0.68 mm, and 2.90 mm, respectively. All three scanogram techniques showed excellent reliability and accuracy. Radiographic scanogram remains the gold standard for leg length measurement. MRI scanogram is slightly less accurate compared with radiographic scanogram, but it does not use ionizing radiation. MRI scanogram merits clinical study and comparison with the traditional radiographic scanogram method for measurement of limb length.
引用
收藏
页码:747 / 749
页数:3
相关论文
共 19 条
  • [1] COMPARISON OF ORTHOROENTGENOGRAPHY AND COMPUTED-TOMOGRAPHY IN THE MEASUREMENT OF LIMB-LENGTH DISCREPANCY
    AARON, A
    WEINSTEIN, D
    THICKMAN, D
    EILERT, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) : 897 - 902
  • [2] LEG LENGTH DETERMINATION BY CT DIGITAL RADIOGRAPHY
    AITKEN, AGF
    FLODMARK, O
    NEWMAN, DE
    KILCOYNE, RF
    SHUMAN, WP
    MACK, LA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (03) : 613 - 615
  • [3] COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1995, 346 (8982): : 1085 - 1087
  • [4] A NOTE ON THE USE OF THE INTRACLASS CORRELATION-COEFFICIENT IN THE EVALUATION OF AGREEMENT BETWEEN 2 METHODS OF MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 1990, 20 (05) : 337 - 340
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] GREEN WT, 1946, J BONE JOINT SURG, V28, P60
  • [7] CT SCANOGRAMS FOR MEASURING LEG LENGTH DISCREPANCY
    HELMS, CA
    MCCARTHY, S
    [J]. RADIOLOGY, 1984, 151 (03) : 802 - 802
  • [8] LIMB-LENGTH DISCREPANCY MEASURED WITH COMPUTERIZED AXIAL TOMOGRAPHIC EQUIPMENT
    HUURMAN, WW
    JACOBSEN, FS
    ANDERSON, JC
    CHU, WK
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (05) : 699 - 705
  • [9] JOHNSON SR, 1997, J ORTHOP SPORT PHYS, V25, P253
  • [10] LEG LENGTH INEQUALITY MEASURED BY ULTRASOUND AND CLINICAL METHODS
    JUNK, S
    TERJESEN, T
    ROSSVOLL, I
    BRATEN, M
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1992, 14 (03) : 185 - 188