Time function triple Langmuir probe measurements in low frequency pulsed DC discharge plasma
被引:6
作者:
Farooq, M. U.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Elect Sci & Technol China, Inst Fundamental & Frontier Sci, Chengdu 610054, Sichuan, Peoples R ChinaUniv Elect Sci & Technol China, Inst Fundamental & Frontier Sci, Chengdu 610054, Sichuan, Peoples R China
Farooq, M. U.
[1
]
Ali, A.
论文数: 0引用数: 0
h-index: 0
机构:
Int Islamic Univ, Dept Phys, Islamabad 1243, PakistanUniv Elect Sci & Technol China, Inst Fundamental & Frontier Sci, Chengdu 610054, Sichuan, Peoples R China
Ali, A.
[2
]
Qayyum, A.
论文数: 0引用数: 0
h-index: 0
机构:
Int Islamic Univ, Dept Phys, Islamabad 1243, PakistanUniv Elect Sci & Technol China, Inst Fundamental & Frontier Sci, Chengdu 610054, Sichuan, Peoples R China
Qayyum, A.
[2
]
Naz, M. Y.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Teknol PETRONAS, Dept Fundamental & Appl Sci, Tronoh 31750, Perak, Malaysia
Univ Agr Faisalabad, Dept Phys, Faisalabad 38040, PakistanUniv Elect Sci & Technol China, Inst Fundamental & Frontier Sci, Chengdu 610054, Sichuan, Peoples R China
Naz, M. Y.
[3
,5
]
Khan, Y.
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Coll Engn, Riyadh 12372, Saudi ArabiaUniv Elect Sci & Technol China, Inst Fundamental & Frontier Sci, Chengdu 610054, Sichuan, Peoples R China
Khan, Y.
[4
]
Shukrullah, S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Teknol PETRONAS, Dept Fundamental & Appl Sci, Tronoh 31750, Perak, Malaysia
Univ Agr Faisalabad, Dept Phys, Faisalabad 38040, PakistanUniv Elect Sci & Technol China, Inst Fundamental & Frontier Sci, Chengdu 610054, Sichuan, Peoples R China
Shukrullah, S.
[3
,5
]
Ghaffar, Ch. A.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Agr Faisalabad, Dept Phys, Faisalabad 38040, PakistanUniv Elect Sci & Technol China, Inst Fundamental & Frontier Sci, Chengdu 610054, Sichuan, Peoples R China
Ghaffar, Ch. A.
[5
]
机构:
[1] Univ Elect Sci & Technol China, Inst Fundamental & Frontier Sci, Chengdu 610054, Sichuan, Peoples R China
[2] Int Islamic Univ, Dept Phys, Islamabad 1243, Pakistan
[3] Univ Teknol PETRONAS, Dept Fundamental & Appl Sci, Tronoh 31750, Perak, Malaysia
[4] King Saud Univ, Coll Engn, Riyadh 12372, Saudi Arabia
This study investigated the temporal profiles of electron temperature and number density in rectified DC air discharge generated with a 50 Hz step-up transformer. An in-house built triple Langmuir probe and circuitry were used to diagnose the plasma parameters as a function of input voltage and filling gas pressure. A tungsten metal wire capable of withstanding the high temperatures was used as probe tip material. The temporal profiles revealed an increase in electron temperature with input voltage in the range of 380 to 450 V, whereas, an inverse relation between number density and input voltage was evident in the given work. The observed trend in the plasma parameters was absolutely reversed in case of the filling gas pressure. The electron temperature linearly decreased with an increase in pressure from 1 to 4 mbar, whereas a linear increase in number density with pressure was seen in the temporal profiles. Finally, it was concluded that the results for the tested plasma parameters were consistent and the in-house built probe functioned well in DC discharge for the used range of voltage and filling pressure.