Experimental and numerical studies of prefabricated structures using CFST frame and composite wall

被引:22
作者
Bian, Jinliang [1 ,2 ]
Cao, Wanlin [3 ]
Qiao, Qiyun [3 ]
Zhang, Jianwei [3 ]
机构
[1] Tianjin Chengjian Univ, Sch Civil Engn, Tianjin 300384, Peoples R China
[2] Tianjin Chengjian Univ, Tianjin Key Lab Civil Struct Protect & Reinforcem, Tianjin 300384, Peoples R China
[3] Beijing Univ Technol, Fac Architecture Civil & Transportat Engn, Beijing 100124, Peoples R China
基金
国家重点研发计划;
关键词
Prefabricated structure; Lightweight CFST frame; Embedded steel plate composite wall; Experimental study; Numerical simulation; COLUMN JOINT; SQUARE STEEL; CONCRETE; PERFORMANCE; TUBE; BEHAVIOR; PANELS;
D O I
10.1016/j.jobe.2021.103886
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A prefabricated structure composed of a lightweight concrete filled steel tube (CFST) frame and an embedded steel plate (ESP) composite wall is proposed, known as a CFST frame-ESP composite wall. To study the seismic performance of the prefabricated structure, low reversed cyclic loading tests of six full-scale specimens were performed, including five CFST frame-ESP composite walls with different wall details and one bare frame. The failure characteristics, hysteretic characteristics, bearing capacity, stiffness degradation, and energy dissipation capacity of the specimens were compared, and a simplified model was used for the ESP composite wall. Based on OpenSees finite element software, finite element simulation and parameter analysis were performed using a simplified model. The calculated results agree well with the experimental results. The results show that the ESP composite wall can improve the bearing capacity, initial stiffness, and energy dissipation capacity of the CFST frame significantly. The use of a rebar brace decreased the concrete damage and increased the ultimate bearing capacity, initial stiffness, and energy dissipation capacity of the ESP composite wall. The mechanical characteristics of the EPS composite wall is considered in the simplified model. The modeling method presented herein can be used to analyze the abovementioned type of structure.
引用
收藏
页数:22
相关论文
共 35 条
[1]   An experimental study on reinforced concrete partially infilled frames [J].
Anil, Ozgur ;
Altin, Sinan .
ENGINEERING STRUCTURES, 2007, 29 (03) :449-460
[2]  
[Anonymous], 2010, Code for design of concrete structures
[3]  
[Anonymous], 2003, 500812002 GBT
[4]   Cyclic loading tests of thin-walled square steel tube beam-column joint with different joint details [J].
Bian, Jinliang ;
Cao, Wanlin ;
Zhang, Zongmin ;
Qiao, Qiyun .
STRUCTURES, 2020, 25 :386-397
[5]  
Cai J., 2008, J S CHINA U TECHNOLO, P1105
[6]  
Cao WL, 2010, RILEM PROC, V73, P652
[7]  
Chrysostomou CZ., 1991, EFFECTS DEGRADING IN
[8]  
Eurocode 4, 1994, 1994141994 DD ENV BR
[9]  
Feng Weidong, 2009, NONLINEAR SEISMIC RE
[10]   Simplified model for partially-composite precast concrete insulated wall panels subjected to lateral loading [J].
Gombeda, Matthew J. ;
Trasborg, Patrick ;
Naito, Clay J. ;
Quiel, Spencer E. .
ENGINEERING STRUCTURES, 2017, 138 :367-380