High-precision isotope ratio analysis of inorganic bromide by continuous flow MC-ICPMS

被引:13
作者
Gelman, Faina [1 ]
Halicz, Ludwik [1 ]
机构
[1] Geol Survey Israel, IL-95501 Jerusalem, Israel
关键词
Bromine isotope ratio; Bromide on-line oxidation; MC-ICPMS; Sr external spike; PLASMA-MASS SPECTROMETRY; CHLORINE; MS; GROUNDWATERS; CARBONATES;
D O I
10.1016/j.ijms.2011.01.003
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The study proposes a new method for the high-precision determination of bromine isotope ratio in inorganic samples. In the suggested method, inorganic bromide is wet-oxidized into molecular bromine and transferred into the MC-ICPMS by continuous flow of helium. Analysis of natural inorganic bromide samples from various sources revealed identical delta(81) Br values within the range of the method uncertainty. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:211 / 213
页数:3
相关论文
共 50 条
[21]   Accuracy of laser-ablation (LA)-MC-ICPMS Sr isotope analysis of (bio)apatite - a problem reassessed [J].
Mueller, Wolfgang ;
Anczkiewicz, Robert .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (01) :259-269
[22]   Efficient separation of boron using solid-phase extraction for boron isotope analysis by MC-ICPMS [J].
He, Maoyong ;
Jin, Zhangdong ;
Lu, Hai ;
Ren, Tongxiang .
ANALYTICAL METHODS, 2015, 7 (24) :10322-10327
[23]   Calibration of Mo isotope amount ratio measurements by MC-ICPMS using normalisation to an internal standard and improved experimental design [J].
Malinovsky, Dmitry ;
Dunn, Philip J. H. ;
Goenaga-Infante, Heidi .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (10) :1978-1988
[24]   Precise analysis of calcium stable isotope variations in biological apatites using laser ablation MC-ICPMS [J].
Tacail, Theo ;
Telouk, Philippe ;
Balter, Vincent .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (01) :152-162
[25]   Platinum stable isotope analysis of geological standard reference materials by double-spike MC-ICPMS [J].
Creech, J. B. ;
Baker, J. A. ;
Handler, M. R. ;
Bizzarroc, M. .
CHEMICAL GEOLOGY, 2014, 363 :293-300
[26]   Demonstrating the metrological compatibility of uranium isotope amount ratio measurement results obtained by GSMS, TIMS and MC-ICPMS techniques [J].
de Oliveira Junior, O. Pereira ;
de Bolle, W. ;
Alonso, A. ;
Richter, S. ;
Wellum, R. ;
Ponzevera, E. ;
Sarkis, J. E. S. ;
Kessel, R. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 291 (1-2) :48-54
[27]   High-Precision Barium Isotope Measurements of Carbonates by MC-ICP-MS [J].
Zeng, Zhen ;
Li, Xiaohua ;
Liu, Yi ;
Huang, Fang ;
Yu, Hui-Min .
GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2019, 43 (02) :291-300
[28]   Chemical procedure for Zn purification and double spike method for high precision measurement of Zn isotopes by MC-ICPMS [J].
Amet, Quentin ;
Fitoussi, Caroline .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 457
[29]   Hg isotope ratio measurements of methylmercury in fish tissues using HPLC with off line cold vapour generation MC-ICPMS [J].
Entwisle, John ;
Malinovsky, Dmitriy ;
Dunn, Philip J. H. ;
Goenaga-Infante, Heidi .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (10) :1645-1654
[30]   High-precision barium isotope measurements by MC-ICP-MS [J].
Nan, Xiaoyun ;
Wu, Fei ;
Zhang, Zhaofeng ;
Hou, Zhenhui ;
Huang, Fang ;
Yu, Huimin .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (11) :2307-2315