Endoscopic Management of Post-Liver Transplantation Biliary Strictures With the Use of Fully Covered Metallic Stents

被引:10
作者
Jimenez-Perez, M. [1 ,2 ]
Melgar Simon, J. M. [2 ]
Duran Campos, A. [2 ,3 ]
Gonzalez Grande, R. [1 ,2 ]
Rodrigo Lopez, J. M. [1 ,2 ]
Manteca Gonzalez, R. [2 ]
机构
[1] Hosp Reg Univ Malaga, Unidad Hepatol Trasplante Hepat, Malaga, Spain
[2] Hosp Reg Univ Malaga, Unidad Gest Clin Aparato Digest, Avda Carlos Haya S-N, Malaga 29010, Spain
[3] Hosp Reg Univ Malaga, Unidad Endoscopia, Malaga, Spain
关键词
BILE-DUCT STRICTURES; TEMPORARY PLACEMENT; COMPLICATIONS; THERAPY; STENOSIS; VIDEO;
D O I
10.1016/j.transproceed.2016.09.008
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Objective. The aim of this work was to evaluate the safety and efficacy of a fully covered self-expandable metal stent (FCSEMS) in the treatment of post-liver transplantation biliary strictures. Methods. From October 2009 to October 2014, 44 patients with post-liver transplantation biliary stenosis were treated with the use of endoscopic retrograde cholangiography and placement of FCSEMS after informed consent. The FCSEMS was scheduled to remain in situ for 3-6 months. Patients were followed at regular intervals to evaluate for symptoms and liver function tests. Technical success, complications, and patient outcome were analyzed. Results. All of the strictures were anastomotic, 52% having occurred within the 1st year following the transplantation. Placement of the FCSEMS was possible on the 1st attempt in 54% of patients. Stricture resolution at the time of stent removal was seen in 100% of the cases. During an average follow-up of 27.83 +/- 18.3 months after stent removal, stenosis recurred in 9 out of 41 patients (21.9%). The average time of recurrence was 11.78 +/- 13.3 months. In all of these cases, the recurrence was resolved by means of placement of another FCSEMS. In 4 cases, the recurrence was associated with a migration of the prosthesis, partial in 2 cases and total in 2 cases. Stent migration occurred in a total of 17 of the 41 patients (41.4%), in 13 of the 32 (40.6%) who had no recurrence of stenosis and in 4 of the 9 (44.4%) of those who experienced recurrence. The average numbers of endoscopic retrograde cholangiography studies required per patient were 2.8 in those with no recurrence and 3.3 in those with recurrence. No death was associated with the process. Conclusions. FCSEMS is a safe effective alternative to plastic stents in the treatment of post-transplantation biliary strictures, resulting in a lower risk of complications and better patient acceptance.
引用
收藏
页码:2510 / 2514
页数:5
相关论文
共 50 条
[1]   Fully covered metallic stents for anastomotic biliary strictures after living donor liver transplantation [J].
Komatsu, Naohiro ;
Ozawa, Eisuke ;
Fukushima, Masanori ;
Sawase, Hironori ;
Nagata, Kazuyoshi ;
Miuma, Satoshi ;
Miyaaki, Hisamitsu ;
Soyama, Akihiko ;
Hidaka, Masaaki ;
Eguchi, Susumu ;
Nakao, Kazuhiko .
DEN OPEN, 2023, 3 (01)
[2]   New fully covered self-expandable metallic stents for anastomotic biliary strictures after liver transplantation [J].
Frederic, Prat ;
Fabiano, Perdigao .
CLINICS AND RESEARCH IN HEPATOLOGY AND GASTROENTEROLOGY, 2019, 43 (04) :357-358
[3]   Application of Fully Covered Self-Expandable Metallic Stents with and without Antimigration Waist Versus Repeated Plastic Biliary Stent Placement in Management of Anastomotic Biliary Strictures After Orthotopic Liver Transplantation [J].
Zeair, Samir ;
Butkiewicz, Filip ;
Butkiewicz, Jacek ;
Stasiuk, Robert .
ANNALS OF TRANSPLANTATION, 2017, 22 :719-724
[4]   Multiple plastic versus fully covered metal stents for managing post-liver transplantation anastomotic biliary strictures: a meta-analysis of randomized controlled trials [J].
Tringali, Alberto ;
Tarantino, Ilaria ;
Barresi, Luca ;
Traina, Mario ;
Bonato, Giulia ;
Cintolo, Marcello ;
Hassan, Cesare ;
Mutignani, Massimiliano ;
Adler, Douglas G. .
ANNALS OF GASTROENTEROLOGY, 2019, 32 (04) :407-+
[5]   Biodegradable Biliary Stents for Percutaneous Treatment of Post-liver Transplantation Refractory Benign Biliary Anastomotic Strictures [J].
Battistel, Michele ;
Senzolo, Marco ;
Ferrarese, Alberto ;
Lupi, Amalia ;
Cillo, Umberto ;
Boccagni, Patrizia ;
Zanus, Giacomo ;
Stramare, Roberto ;
Quaia, Emilio ;
Burra, Patrizia ;
Barbiero, Giulio .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 43 (05) :749-755
[6]   A randomized trial of a fully covered self-expandable metallic stent versus plastic stents in anastomotic biliary strictures after liver transplantation [J].
Kaffes, Arthur ;
Griffin, Sean ;
Vaughan, Rhys ;
James, Martin ;
Chua, Tee ;
Tee, Hoi ;
Dinesen, Lotte ;
Corte, Crispin ;
Gill, Raghubinder .
THERAPEUTIC ADVANCES IN GASTROENTEROLOGY, 2014, 7 (02) :64-71
[7]   Successful Management of Benign Biliary Strictures With Fully Covered Self-Expanding Metal Stents [J].
Deviere, Jacques ;
Reddy, D. Nageshwar ;
Puespoek, Andreas ;
Ponchon, Thierry ;
Bruno, Marco J. ;
Bourke, Michael J. ;
Neuhaus, Horst ;
Roy, Andre ;
Gonzalez-Huix Llado, Ferran ;
Barkun, Alan N. ;
Kortan, Paul P. ;
Navarrete, Claudio ;
Peetermans, Joyce ;
Blero, Daniel ;
Lakhtakia, Sundeep ;
Dolak, Werner ;
Lepilliez, Vincent ;
Poley, Jan W. ;
Tringali, Andrea ;
Costamagna, Guido .
GASTROENTEROLOGY, 2014, 147 (02) :385-395
[8]   Covered metal stents in endoscopic therapy of biliary complications after liver transplantation [J].
Cantu, Paolo ;
Tenca, Andrea ;
Parzanese, Ilaria ;
Penagini, Roberto .
DIGESTIVE AND LIVER DISEASE, 2016, 48 (08) :836-842
[9]   Endoscopic management of biliary strictures after liver transplantation [J].
Williams, Emmanuelle D. ;
Draganov, Peter V. .
WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (30) :3725-3733
[10]   Fully covered self-expandable metallic stents in benign biliary strictures: a multicenter study on efficacy and safety [J].
Tarantino, I. ;
Mangiavillano, B. ;
Di Mitri, R. ;
Barresi, L. ;
Mocciaro, F. ;
Granata, A. ;
Masci, E. ;
Curcio, G. ;
Di Pisa, M. ;
Marino, A. ;
Traina, M. .
ENDOSCOPY, 2012, 44 (10) :923-927