Respiratory motion correction in 4D-PET by simultaneous motion estimation and image reconstruction (SMEIR)

被引:16
作者
Kalantari, Faraz [1 ]
Li, Tianfang [2 ]
Jin, Mingwu [3 ]
Wang, Jing [1 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Radiat Oncol, Dallas, TX 75390 USA
[2] Univ Pittsburgh, Inst Canc, Dept Radiat Oncol, Pittsburgh, PA 15232 USA
[3] Univ Texas Arlington, Dept Phys, POB 19059, Arlington, TX 76019 USA
基金
美国国家卫生研究院;
关键词
PET motion correction; PET quantification; 4D PET; POSITRON-EMISSION-TOMOGRAPHY; STANDARDIZED UPTAKE VALUES; ITERATIVE RECONSTRUCTION; ATTENUATION CORRECTION; LUNG-CANCER; PET IMAGES; CT; IMPACT; MRI; ALGORITHMS;
D O I
10.1088/0031-9155/61/15/5639
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In conventional 4D positron emission tomography (4D-PET), images from different frames are reconstructed individually and aligned by registration methods. Two issues that arise with this approach are as follows: (1) the reconstruction algorithms do not make full use of projection statistics; and (2) the registration between noisy images can result in poor alignment. In this study, we investigated the use of simultaneous motion estimation and image reconstruction (SMEIR) methods for motion estimation/correction in 4D-PET. A modified ordered-subset expectation maximization algorithm coupled with total variation minimization (OSEM-TV) was used to obtain a primary motion-compensated PET (pmc-PET) from all projection data, using Demons derived deformation vector fields (DVFs) as initial motion vectors. A motion model update was performed to obtain an optimal set of DVFs in the pmc-PET and other phases, by matching the forward projection of the deformed pmc-PET with measured projections from other phases. The OSEM-TV image reconstruction was repeated using updated DVFs, and new DVFs were estimated based on updated images. A 4D-XCAT phantom with typical FDG biodistribution was generated to evaluate the performance of the SMEIR algorithm in lung and liver tumors with different contrasts and different diameters (10-40 mm). The image quality of the 4D-PET was greatly improved by the SMEIR algorithm. When all projections were used to reconstruct 3D-PET without motion compensation, motion blurring artifacts were present, leading up to 150% tumor size overestimation and significant quantitative errors, including 50% underestimation of tumor contrast and 59% underestimation of tumor uptake. Errors were reduced to less than 10% in most images by using the SMEIR algorithm, showing its potential in motion estimation/correction in 4D-PET.
引用
收藏
页码:5639 / 5661
页数:23
相关论文
共 60 条
  • [1] Joint image and motion reconstruction for PET using a B-spline motion model
    Blume, Moritz
    Navab, Nassir
    Rafecas, Magdalena
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (24) : 8249 - 8270
  • [2] Joint Reconstruction of Image and Motion in Gated Positron Emission Tomography
    Blume, Moritz
    Martinez-Moeller, Axel
    Keil, Andreas
    Navab, Nassir
    Rafecas, Magdalena
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (11) : 1892 - 1906
  • [3] Brune C, 2009, LECT NOTES COMPUT SC, V5567, P235, DOI 10.1007/978-3-642-02256-2_20
  • [4] Bruyant PP, 2002, J NUCL MED, V43, P1343
  • [5] Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: A feasibility study
    Cai, Jing
    Chang, Zheng
    Wang, Zhiheng
    Segars, William Paul
    Yin, Fang-Fang
    [J]. MEDICAL PHYSICS, 2011, 38 (12) : 6384 - 6394
  • [6] Geographic miss of lung tumours due to respiratory motion: a comparison of 3D vs 4D PET/CT defined target volumes
    Callahan, Jason
    Kron, Tomas
    Siva, Shankar
    Simoens, Nathalie
    Edgar, Amanda
    Everitt, Sarah
    Schneider, Michal E.
    Hicks, Rodney J.
    [J]. RADIATION ONCOLOGY, 2014, 9
  • [7] The impact of 18F-FDG PET/CT in patients with liver metastases
    Chua, Siew C.
    Groves, Ashley M.
    Kayani, Irfan
    Menezes, Leon
    Gacinovic, Svetislav
    Du, Yong
    Bomanji, Jamshed B.
    Ell, Peter J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (12) : 1906 - 1914
  • [8] MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI
    Chun, Se Young
    Reese, Timothy G.
    Ouyang, Jinsong
    Guerin, Bastien
    Catana, Ciprian
    Zhu, Xuping
    Alpert, Nathaniel M.
    El Fakhri, Georges
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) : 1284 - 1291
  • [9] PET-CT: accuracy of PET and CT spatial registration of lung lesions
    Cohade, C
    Osman, M
    Marshall, LT
    Wahl, RL
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (05) : 721 - 726
  • [10] A Pilot Evaluation of a 4-Dimensional Cone-Beam Computed Tomographic Scheme Based on Simultaneous Motion Estimation and Image Reconstruction
    Dang, Jun
    Gu, Xuejun
    Pan, Tinsu
    Wang, Jing
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 91 (02): : 410 - 418