Lung iodine mapping by subtraction with image registration allowing for tissue sliding

被引:4
|
作者
Mohr, Brian [1 ]
Brink, Monique [2 ]
Oostveen, Luuk J. [2 ]
Schuijf, Joanne D. [3 ]
Prokop, Mathias [2 ]
机构
[1] Toshiba Med Visualizat Syst Europe, Edinburgh, Midlothian, Scotland
[2] Radboud Univ Nijmegen, Med Ctr, Nijmegen, Netherlands
[3] Toshiba Med Syst Europe, Zoetermeer, Netherlands
来源
MEDICAL IMAGING 2016: IMAGE PROCESSING | 2016年 / 9784卷
关键词
Registration; Subtraction; Lung; CT;
D O I
10.1117/12.2216262
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Pulmonary embolism is a fairly common and serious entity, so rapid diagnosis and treatment has a significant impact on morbidity and mortality rates. Iodine maps representing tissue perfusion enhancement are commonly generated by dual-energy CT acquisitions to provide information about the effect of the embolism on pulmonary perfusion. Alternatively, the iodine map can be generated by subtracting pre-from post-contrast CT scans as previously reported. Although accurate image registration is essential, subtraction has the advantage of a higher signal-to-noise ratio and suppression of bone. This paper presents an improvement over the previously reported registration algorithm. Significantly, allowance for sliding motion at tissue boundaries is included in the regularization. Pre- and post-contrast helical CT scans were acquired for thirty subjects using a Toshiba Aquilion ONE (R) scanner. Ten of these subjects were designated for algorithm development, while the remaining twenty were reserved for qualitative clinical evaluation. Quantitative evaluation was performed against the previously reported method and using publicly available data for comparison against other methods. Comparison of 100 landmarks in seven datasets shows no change in the mean Euclidean error of 0.48 mm, compared to the previous method. Evaluation in the publicly available DIR-Lab data with 300 annotations results in a mean Euclidean error of 1.17 mm in the ten 4DCT cases and 3.37 mm in the ten COPDGene cases. Clinical evaluation on a sliding scale from 1 (excellent) to 5 (non-diagnostic) indicates a slight, but non-significant, improvement in registration adequacy from 3.1 to 2.9.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Indirect pet-pet image registration to monitor lung cancer tumor
    Ouksili, Z.
    Tauber, C.
    Nalis, J.
    Batatia, H.
    Caselles, O.
    Courbon, F.
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [42] Radiation dose and image quality in K-edge subtraction computed tomography of lung in vivo
    Strengell, S.
    Keyrilainen, J.
    Suortti, P.
    Bayat, S.
    Sovijarvi, A. R. A.
    Porra, L.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 1305 - 1313
  • [43] A tool for temporal comparison of mammograms: Image toggling and dense-tissue-preserving registration
    Hasegawa, Akira
    Neemuchwala, Huzefa
    Tsunoda-Shimizu, Hiroko
    Honda, Satoru
    Shimura, Kazuo
    Sato, Minoru
    Koyama, Tomomi
    Kikuchi, Mari
    Hiramatsu, Sonoe
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 447 - +
  • [44] Nonuniform B-Spline Lung Image Registration Based on Adaptive Regularization Term
    Fan Panyun
    Li Min
    LASER & OPTOELECTRONICS PROGRESS, 2022, 59 (10)
  • [45] Quantitative image analysis of lung connective tissue in murine silicosis
    Antonini, JM
    Hemenway, DR
    Davis, GS
    EXPERIMENTAL LUNG RESEARCH, 2000, 26 (02) : 71 - 88
  • [46] Tissue-Volume Preserving Deformable Image Registration for 4DCT Pulmonary Images
    Zhao, Bowen
    Christensen, Gary E.
    Song, Joo Hyun
    Pan, Yue
    Gerard, Sarah E.
    Reinhardt, Joseph M.
    Du, Kaifang
    Patton, Taylor
    Bayouth, John M.
    Hugo, Geoffrey D.
    PROCEEDINGS OF 29TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, (CVPRW 2016), 2016, : 481 - 489
  • [47] Improved B-spline image registration between exhale and inhale lung CT images based on intensity and gradient orientation information
    Nam, Woo Hyun
    Oh, Jihun
    Yi, Jonghyon
    Park, Yongsup
    Cho, Hansu
    Kim, Sukjin
    MEDICAL IMAGING 2016: IMAGE PROCESSING, 2016, 9784
  • [48] A GPU-based symmetric non-rigid image registration method in human lung
    Haghighi, Babak
    D. Ellingwood, Nathan
    Yin, Youbing
    Hoffman, Eric A.
    Lin, Ching-Long
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (03) : 355 - 371
  • [49] Statistical Modeling of 4D Respiratory Lung Motion Using Diffeomorphic Image Registration
    Ehrhardt, Jan
    Werner, Rene
    Schmidt-Richberg, Alexander
    Handels, Heinz
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 251 - 265
  • [50] A GPU-based symmetric non-rigid image registration method in human lung
    Babak Haghighi
    Nathan D. Ellingwood
    Youbing Yin
    Eric A. Hoffman
    Ching-Long Lin
    Medical & Biological Engineering & Computing, 2018, 56 : 355 - 371