Lung iodine mapping by subtraction with image registration allowing for tissue sliding

被引:4
|
作者
Mohr, Brian [1 ]
Brink, Monique [2 ]
Oostveen, Luuk J. [2 ]
Schuijf, Joanne D. [3 ]
Prokop, Mathias [2 ]
机构
[1] Toshiba Med Visualizat Syst Europe, Edinburgh, Midlothian, Scotland
[2] Radboud Univ Nijmegen, Med Ctr, Nijmegen, Netherlands
[3] Toshiba Med Syst Europe, Zoetermeer, Netherlands
来源
MEDICAL IMAGING 2016: IMAGE PROCESSING | 2016年 / 9784卷
关键词
Registration; Subtraction; Lung; CT;
D O I
10.1117/12.2216262
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Pulmonary embolism is a fairly common and serious entity, so rapid diagnosis and treatment has a significant impact on morbidity and mortality rates. Iodine maps representing tissue perfusion enhancement are commonly generated by dual-energy CT acquisitions to provide information about the effect of the embolism on pulmonary perfusion. Alternatively, the iodine map can be generated by subtracting pre-from post-contrast CT scans as previously reported. Although accurate image registration is essential, subtraction has the advantage of a higher signal-to-noise ratio and suppression of bone. This paper presents an improvement over the previously reported registration algorithm. Significantly, allowance for sliding motion at tissue boundaries is included in the regularization. Pre- and post-contrast helical CT scans were acquired for thirty subjects using a Toshiba Aquilion ONE (R) scanner. Ten of these subjects were designated for algorithm development, while the remaining twenty were reserved for qualitative clinical evaluation. Quantitative evaluation was performed against the previously reported method and using publicly available data for comparison against other methods. Comparison of 100 landmarks in seven datasets shows no change in the mean Euclidean error of 0.48 mm, compared to the previous method. Evaluation in the publicly available DIR-Lab data with 300 annotations results in a mean Euclidean error of 1.17 mm in the ten 4DCT cases and 3.37 mm in the ten COPDGene cases. Clinical evaluation on a sliding scale from 1 (excellent) to 5 (non-diagnostic) indicates a slight, but non-significant, improvement in registration adequacy from 3.1 to 2.9.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Registration of Image Modalities for Analyses of Tissue Samples Using 3D Image Modelling
    Hermann, Juliane
    Brehmer, Kai
    Jankowski, Vera
    Lellig, Michaela
    Hohl, Mathias
    Mahfoud, Felix
    Speer, Timotheus
    Schunk, Stefan J.
    Tschernig, Thomas
    Thiele, Herbert
    Jankowski, Joachim
    PROTEOMICS CLINICAL APPLICATIONS, 2021, 15 (01)
  • [32] 3D-2D image registration in the presence of soft-tissue deformation in image-guided transbronchial interventions
    Vijayan, R.
    Sheth, N.
    Mekki, L.
    Lu, A.
    Uneri, A.
    Sisniega, A.
    Magaraggia, J.
    Kleinszig, G.
    Vogt, S.
    Thiboutot, J.
    Lee, H.
    Yarmus, L.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (01)
  • [33] Lung Image Volume Registration Using the Affine Transformation and Demons Algorithm
    Zhou, Yingyue
    Zang, Hongbin
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [34] Mapping LIDC, RadLex™, and Lung Nodule Image Features
    Pia Opulencia
    David S. Channin
    Daniela S. Raicu
    Jacob D. Furst
    Journal of Digital Imaging, 2011, 24 : 256 - 270
  • [35] Deformable image registration of heterogeneous human lung incorporating the bronchial tree
    Al-Mayah, Adil
    Moseley, Joanne
    Velec, Mike
    Hunter, Shannon
    Brock, Kristy
    MEDICAL PHYSICS, 2010, 37 (09) : 4560 - 4571
  • [36] TISSUE CHARACTERIZATION BY IMAGE-PROCESSING SUBTRACTION - WINDOWING OF SPECIFIC T(1) VALUES
    BONDESTAM, S
    LAMMINEN, A
    KOMU, M
    POUTANEN, VP
    ALANEN, A
    HALAVAARA, J
    MAGNETIC RESONANCE IMAGING, 1992, 10 (06) : 989 - 995
  • [37] Sliding at First-Order: Higher-Order Momentum Distributions for Discontinuous Image Registration
    Bao, Lili
    Lu, Jiahao
    Ying, Shihui
    Sommer, Stefan
    SIAM JOURNAL ON IMAGING SCIENCES, 2024, 17 (02) : 861 - 887
  • [38] Pulmonary CT image registration and warping for tracking tissue deformation during the respiratory cycle through 3D consistent image registration
    Li, Baojun
    Christensen, Gary E.
    Hoffman, Eric A.
    McLennan, Geoffrey
    Reinhardt, Joseph M.
    MEDICAL PHYSICS, 2008, 35 (12) : 5575 - 5583
  • [39] Lung-CRNet: A convolutional recurrent neural network for lung 4DCT image registration
    Lu, Jiayi
    Jin, Renchao
    Song, Enmin
    Ma, Guangzhi
    Wang, Manyang
    MEDICAL PHYSICS, 2021, 48 (12) : 7900 - 7912
  • [40] Estimation of regional lung expansion via 3D image registration
    Pan, Y
    Kumar, D
    Hoffman, EA
    Christensen, GE
    McLennan, G
    Song, JH
    Ross, A
    Simon, BA
    Reinhardt, JM
    Medical Imaging 2005: Physiology, Function, and Structure From Medical Images, Pts 1 and 2, 2005, 5746 : 453 - 464