Signal Quality Assessment of Compressively Sensed Electrocardiogram

被引:6
|
作者
Abdelazez, Mohamed [1 ]
Rajan, Sreeraman [1 ]
Chan, Adrian D. C. [1 ]
机构
[1] Carleton Univ, Dept Syst & Comp Engineer, Ottawa, ON K1S 5B6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Electrocardiography; Signal to noise ratio; Databases; Motion artifacts; Rhythm; Monitoring; Heart beat; Compressive sensing; electrocardiogram; machine learning; signal quality assessment; signal quality index; ATRIAL-FIBRILLATION; CLASSIFICATION;
D O I
10.1109/TBME.2022.3170047
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Develop a signal quality index (SQI) to determine the quality of compressively sensed electrocardiogram (ECG) by estimating the signal-to-noise ratio (SNR). Methods: The SQI used random forests, with the ratio of the standard deviations of an ECG segment and a clean ECG and the Wasserstein metric between the amplitude distributions of an ECG segment and a clean ECG, as features. The SQI was tested using the Long-Term Atrial Fibrillation Database (LTAFDB) and the PhysioNet/CinC Challenge 2011 Database Set A (CinCDB). Clean ECG segments from the LTAFDB were corrupted using simulated motion artifact, with preset SNR between -12 dB and 12 dB. The CinCDB was used as-it-is. The databases were compressively sensed using three types of sensing matrices at three compression ratios (50%, 75%, and 95%). For LTAFDB, the RMSE and Spearman correlation between the SQI and the preset SNR were used for evaluation, while for CinCDB, accuracy and F1 score were used. Results: The average RMSE was 3.18 dB and 3.47 dB in normal and abnormal ECG. The average Spearman correlation was 0.94 and 0.93 in normal and abnormal ECG, respectively. The average accuracy and F1 score were 0.90 and 0.88, respectively. Conclusion: The SQI determined the quality of compressively sensed ECG and generalized across different databases. There was no consequential effect on the SQI due to abnormal ECG or compression using different sensing matrices and compression ratios. Significance: Without reconstruction, the SQI can inform which ECG should be analyzed to reduce false alarms due to contamination.
引用
收藏
页码:3397 / 3406
页数:10
相关论文
共 50 条
  • [31] Joint modeling and reconstruction of a compressively-sensed set of correlated images
    Chang, Kan
    Li, Baoxin
    JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2015, 33 : 286 - 300
  • [32] Deep neural network classification in the compressively sensed spectral image domain
    Cohen, Nadav
    Shmilovich, Shauli
    Oiknine, Yaniv
    Stern, Adrian
    JOURNAL OF ELECTRONIC IMAGING, 2021, 30 (04)
  • [33] Patient Health Monitoring Using Fibrillation Detection in Electrocardiogram Signal
    Premalatha, G.
    Bai, V. Thulasi
    IETE JOURNAL OF RESEARCH, 2024, : 8714 - 8726
  • [34] JOINT RECONSTRUCTION OF COMPRESSIVELY SENSED ULTRASOUND RF ECHOES BY EXPLOITING TEMPORAL CORRELATIONS
    Tzagkarakis, George
    Achim, Alin
    Tsakalides, Panagiotis
    Starck, Jean-Luc
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 632 - 635
  • [35] PATCH-BASED RESIDUAL NETWORKS FOR COMPRESSIVELY SENSED HYPERSPECTRAL IMAGES RESTRUCTION
    Hu, Xiaowei
    Xu, Yang
    Wei, Zhihui
    Liu, Hongyi
    Qian, Ling
    IGARSS 2018 - 2018 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2018, : 6163 - 6166
  • [36] Electrocardiogram Quality Assessment Using Unsupervised Deep Learning
    Seeuws, Nick
    De Vos, Maarten
    Bertrand, Alexander
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (02) : 882 - 893
  • [37] A 0.6-107 μW Energy-Scalable Processor for Directly Analyzing Compressively-Sensed EEG
    Shoaib, Mohammed
    Lee, Kyong Ho
    Jha, Niraj K.
    Verma, Naveen
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2014, 61 (04) : 1105 - 1118
  • [38] Comparative Assessment of Machine Learning Strategies for Electrocardiogram Denoising
    Wang, Brenda
    Hettiarachchi, Chirath
    Suominen, Hanna
    Daskalaki, Elena
    ADVANCES IN ARTIFICIAL INTELLIGENCE, AI 2023, PT I, 2024, 14471 : 495 - 506
  • [39] Classifying Measured Electrocardiogram Signal Quality Using Deep Belief Networks
    Taji, Bahareh
    Chan, Adrian D. C.
    Shirmohammadi, Shervin
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 1393 - 1398
  • [40] Optimization Methods of Compressively Sensed Image Reconstruction Based on Single-Pixel Imaging
    Wei, Ziran
    Zhang, Jianlin
    Xu, Zhiyong
    Liu, Yong
    APPLIED SCIENCES-BASEL, 2020, 10 (09):