Positive end-expiratory pressure following coronary artery bypass grafting

被引:0
作者
Dongelmans, D. A. [1 ]
Hemmes, S. N. [1 ,2 ]
Kudoga, A. C. [1 ]
Veelo, D. P. [1 ]
Binnekade, J. M. [1 ]
Schultz, M. J. [1 ,2 ,3 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Intens Care Med, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, LEICA, NL-1105 AZ Amsterdam, Netherlands
[3] HERMES Crit Care Grp, Amsterdam, Netherlands
关键词
Respiration; artificial; Ventilator weaning; Positive-pressure respiration; Patient compliance; Thoracic surgery; RESPIRATORY-DISTRESS-SYNDROME; ACUTE LUNG INJURY; CARDIOPULMONARY BYPASS; CARDIAC-SURGERY; TIDAL VOLUME; VENTILATION; PULMONARY; RECRUITMENT; EXTUBATION; SUPPORT;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Cardiac surgery-related pulmonary complications include alterations in lung mechanics and anomalies in gas exchange. Higher levels of positive end-expiratory pressure (PEEP) have been suggested to benefit cardiac surgical patients. We compared respiratory compliance, arterial oxygenation and time rill tracheal extubation in 2 cohorts of patients weaned from mechanical ventilation with different levels of PEEP after elective and uncomplicated coronary artery bypass grafting (CABG). We hypothesized that higher PEEP levels improve pulmonary compliance and gas exchange in the first hours of weaning from mechanical ventilation, but not to shorten time till tracheal extubation. Methods. Secondary retrospective analysis of 2 randomized controlled trials: in the first trial patients were weaned with PEEP levels of 10 cmH(2)O for the first 4 hours followed by PEEP levels of 5 cmH(2)O until tracheal extubation (high PEEP, HP); and the second trial patients were weaned with PEEP levels of 5 cmH(2)O during the entire weaning phase (low PEEP LP). The primary endpoint was pulmonary compliance. Secondary endpoints included arterial oxygenation, duration of mechanical ventilation and postoperative pulmonary complications. Results. The analysis included 121 patients; 60 HP patients and 61 LP patients. Baseline characteristics were similar. Compared to LP patients, HP patients had a better pulmonary compliance, 47.2 +/- 14.1 versus 42.7 +/- 10.2 ml/cmH(2)O (P<0.05), and higher levels PaO2, 18.5 +/- 6.6 (138.75 +/- 49.5) versus 16.7 +/- 5.4 (125.25 +/- 40.5) kPa (mmHg) (P<0.05). Patients in the HP group were less frequent in need of supplementary oxygen after ICU discharge. These differences remained present during the entire weaning phase, even after reduction of PEEP. However, HP patients had a longer time rill tracheal extubation, 16.9 +/- 6.1 versus 10.5 +/- 5.0 hours (P<0.001). HP patients had longer durations of postoperative infusion of propofol, 4.9 (2.6-7.4) versus 3.5 (1.8-5.8) hours (P<0.05). There were no differences in use of inotropes. Cummulative fluid balances were sligthly higher in HP patients. Conclusion. Use of higher PEEP levels after elective uncomplicated CABG improves pulmonary compliance and oxygenation but seems to be associated with a delay in tracheal extubation. (Minerva Anestesiol 2012;78:790-800)
引用
收藏
页码:790 / 800
页数:11
相关论文
共 50 条
[1]   Positive end-expiratory pressure after uncomplicated coronary artery bypass grafting: a two-edge sword [J].
Villar, J. ;
Kacmarek, R. M. .
MINERVA ANESTESIOLOGICA, 2012, 78 (07) :743-745
[2]   Effects of Positive End-Expiratory Pressure on Mechanical Ventilation Duration after Coronary Artery Bypass Grafting: A Randomized Clinical Trial [J].
Borges, Daniel Lago ;
da Silva Nina, Vinicius Jose ;
Pereira Baldez, Thiago Eduardo ;
Goncalves Costa, Marina de Albuquerque ;
dos Santos, Natalia Pereira ;
Lima, Ilka Mendes ;
da Silva Lula Psy, Josimary Lima .
ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 20 :773-777
[3]   Impact of Lung Expansion Therapy Using Positive End-Expiratory Pressure in Mechanically Ventilated Patients Submitted to Coronary Artery Bypass Grafting [J].
Lisboa Cordeiro, Andre Luiz ;
Carvalho, Sarah ;
Leite, Maria Clara ;
Vila-Flor, Andre ;
Freitas, Bruno ;
Sousa, Lucas ;
Oliveira, Quetla ;
Guimaraes, Andre Raimundo .
BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2019, 34 (06) :699-703
[4]   Should we titrate positive end-expiratory pressure based on an end-expiratory transpulmonary pressure? [J].
Marini, John J. .
ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6 (19)
[5]   Positive end-expiratory pressure [J].
Gattinoni, Luciano ;
Carlesso, Eleonora ;
Brazzi, Luca ;
Caironi, Pietro .
CURRENT OPINION IN CRITICAL CARE, 2010, 16 (01) :39-44
[6]   Effects of Two Different Levels of Positive End-Expiratory Pressure on the Duration of Intubation in Patients Undergoing Coronary Artery Bypass Graft Surgery [J].
Moradi, Behzad ;
Yarahmadi, Sajad ;
Ansari, Reza ;
Teymouri, Hassan ;
Khademi, Mojgan ;
Abdi, Masoumeh .
IRANIAN HEART JOURNAL, 2020, 21 (03) :55-63
[7]   Positive end-expiratory pressure or no positive end-expiratory pressure: is that the question to be asked? [J].
Villar, J .
CRITICAL CARE, 2003, 7 (02) :192-192
[8]   Positive end-expiratory pressure or no positive end-expiratory pressure: is that the question to be asked? [J].
Jesús Villar .
Critical Care, 7
[9]   Use and titration of positive end-expiratory pressure [J].
Khan, Mansoor A. ;
Frankel, Heidi L. .
CURRENT PROBLEMS IN SURGERY, 2013, 50 (10) :446-451
[10]   Hemodynamics and tissue oxygenation effects after increased in positive end-expiratory pressure in coronary artery bypass surgery [J].
Méndez V.M.F. ;
Oliveira M.F. ;
Baião A.N. ;
Xavier P.A. ;
Gun C. ;
Sperandio P.A. ;
Umeda I.I.K. .
Archives of Physiotherapy, 7 (1)