Calibration of PET scanners with a new traceable point-like Ge68/Ga68 source

被引:0
作者
Hasegawa, Tomoyuki [1 ]
Oda, Keiichi [2 ]
Wada, Yasuhiro [3 ]
Sato, Yasushi [4 ]
Murayama, Hideo [5 ]
Yamada, Takahiro [6 ]
Matsumoto, Mikio [6 ]
Igarashi, Masafumi [7 ]
Iryo, Jun [7 ]
Kamitaka, Hiroaki [7 ]
机构
[1] Kitasato Univ, Allied Hlth sci, Minami Ku, Kitasato 1-15-1, Sagamihara, Kanagawa 228, Japan
[2] Tokyo Metropolitan Inst Gerontol, Tokyo, Japan
[3] RIKEN, Ctr Mol Imaging Sci, Wako, Saitama, Japan
[4] Natl Inst Adv Ind Sci & Technol, Ibaraki, Japan
[5] NIRS, Chiba, Japan
[6] JRIA, Tokyo, Japan
[7] Kitasato Univ, Allied Hlth Sci, Sagamihara, Kanagawa, Japan
来源
2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2011年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have been developing reliable and convenient calibration methods based on the use of point-like radioactive sources. In the present study, we used a newly developed traceable point-like Ge-68/Ga-68 radioactive source for determining calibration factors of a PET scanner. The point-like Ge-68/Ga-68 radioactive source consists of a spherical aluminum absorber with an outer diameter of 8 mm and a small radioactive bead in it. The physical characteristics of the source were evaluated with a Monte Carlo simulation code based on Geant4. The source radioactivity was calibrated at an accredited calibration facility. The point-like source was placed in the field-of-view of a clinical PET scanner, SET-2400W (Shimadzu Co.). The calibration factors determined with the point-like source were consistent with those determined by a conventional standard calibration method within a reasonable uncertainty. In conclusion, the proposed method with newly developed traceable point-like sources is useful for calibrating PET scanners.
引用
收藏
页码:2880 / 2882
页数:3
相关论文
共 6 条
[1]  
Bailey DL, 1997, EUR J NUCL MED, V24, P660
[2]  
Hasegawa T., IEEE T NUCL IN PRESS
[3]   Semi-quantitative and simulation analyses of effects of γ rays on determination of calibration factors of PET scanners with point-like 22Na sources [J].
Hasegawa, Tomoyuki ;
Sato, Yasushi ;
Oda, Keiichi ;
Wada, Yasuhiro ;
Murayama, Hideo ;
Yamada, Takahiro .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (18) :6031-6045
[4]   Characteristics of Annihilation Photons Emitted From New Types of Point-Like 22Na Radioactive Sources With Symmetric Absorber Designs [J].
Hasegawa, Tomoyuki ;
Sato, Yasushi ;
Yamada, Takahiro ;
Oda, Keiichi ;
Wada, Yasuhiro ;
Yoshida, Eiji ;
Murayama, Hideo ;
Takei, Hideyuki .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) :43-50
[5]   A practical method of determining cross-calibration factors of PET scanners by moving a point-like 22Na radioactive source [J].
Hasegawa, Tomoyuki ;
Oda, Keiichi ;
Wada, Yasuhiro ;
Sato, Yasushi ;
Yamada, Takahiro ;
Yoshida, Eiji ;
Murayama, Hideo ;
Saito, Kyoko ;
Takeda, Tohoru ;
Kikuchi, Kei .
ANNALS OF NUCLEAR MEDICINE, 2010, 24 (09) :655-661
[6]   Monte Carlo simulation of the standardization of 22Na using scintillation detector arrays [J].
Sato, Y. ;
Murayama, H. ;
Yamada, T. ;
Hasegawa, T. ;
Oda, K. ;
Unno, Y. ;
Yunoki, A. .
APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) :1354-1357