Fast high performance liquid chromatography separations for proteomic applications using Fused-Core® silica particles

被引:59
|
作者
Schuster, Stephanie A. [1 ]
Boyes, Barry E. [1 ,2 ]
Wagner, Brian M. [1 ]
Kirkland, Joseph J. [1 ]
机构
[1] Adv Mat Technol Inc, Wilmington, DE 19810 USA
[2] Univ Georgia, Complex Carbohydrate Res Ctr, Athens, GA 30602 USA
关键词
Superficially porous particles; Fused-Core particles; Tryptic digests; Peptide separations; Peak capacity; Amyloid peptides; FUSED-CORE PARTICLES; PEPTIDE SEPARATIONS; SHELL PARTICLES; PEAK-CAPACITY; COLUMNS; HPLC; TECHNOLOGY;
D O I
10.1016/j.chroma.2011.07.082
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The separation range of superficially porous particles (Fused-Core (R)) has been extended by design of particles with 160 angstrom pores. These particles show superior kinetics (lower resistance to mass transfer), allowing fast separations of peptides and small proteins (molecular weights of <15,000). The high efficiency and relatively low back pressure of these 2.7 mu m Fused-Core particles has been maintained so that separations can be performed with conventional HPLC instruments. Longer columns can be used for higher resolution of complex mixtures of peptides, such as proteolytic digests. Highly reproducible separations of peptides at elevated temperatures with low pH mobile phases are maintained as a result of a stable bonded stationary phase. The utility of such highly stable materials is exemplified by separations of problematic amyloid peptides at low pH (TFA mobile phase) at an operational temperature of 100 degrees C. To address the issue of poor peptide peak shape in formic acid-containing mobile phases we show that the addition of 10-20 mM ammonium formate improves peak shape, retention and load tolerance of peptides. Use of the Fused-Core particle materials for separations of synthetic peptides and tryptic digests yields peak capacities that are comparable to those obtained using columns packed with sub-2-mu m particles, but with less than one-half of the operating back pressure. A peak capacity of 530 was obtained in 150 min on coupled columns of HALO Peptide ES-C18 with a combined length of 250 mm. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 241
页数:10
相关论文
共 50 条
  • [31] A Fast Determination of Chlorophylls in Barley Grass Juice Powder Using HPLC Fused-Core Column Technology and HPTLC
    Havlikova, Lucie
    Satinsky, Dalibor
    Opletal, Lubomir
    Solich, Petr
    FOOD ANALYTICAL METHODS, 2014, 7 (03) : 629 - 635
  • [32] Research progress on core-shell silica stationary phases for high performance liquid chromatography
    Zhi Mingyu
    He Yi
    Guo Dandan
    Zhu Yan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (04) : 372 - 382
  • [33] Fundamental to achieving fast separations with high efficiency: A review of chromatography with superficially porous particles
    Luo, Chuping
    DeStefano, Joseph J.
    Langlois, Timothy J.
    Boyes, Barry E.
    Schuster, Stephanie A.
    Godinho, Justin M.
    BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (07)
  • [34] Very high pressure liquid chromatography using fully porous particles: Quantitative analysis of fast gradient separations without post-run times
    Stankovich, Joseph J.
    Gritti, Fabrice
    Stevenson, Paul G.
    Beaver, Lois Ann
    Guiochon, Georges
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1324 : 155 - 163
  • [35] Comparison of performance of high-performance liquid chromatography columns packed with superficially and fully porous 2.5 μm particles using kinetic plots
    Fanigliulo, Ameriga
    Cabooter, Deirdre
    Bellazzi, Guido
    Tramarin, Davide
    Allieri, Brigida
    Rottigni, Alessandro
    Desmet, Gert
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (23-24) : 3655 - 3665
  • [36] The History of the Core-Shell Particles and Applications in Active Pharmaceutical Ingredients Via Liquid Chromatography
    Gumustas, Mehmet
    Zalewski, Przemyslaw
    Ozkan, Sibel A.
    Uslu, Bengi
    CHROMATOGRAPHIA, 2019, 82 (01) : 17 - 48
  • [37] High peak capacity separations of peptides in reversed-phase gradient elution liquid chromatography on columns packed with porous shell particles
    Marchetti, Nicola
    Guiochon, Georges
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1176 (1-2) : 206 - 216
  • [38] Recent progress in online, comprehensive two-dimensional high-performance liquid chromatography for non-proteomic applications
    Dwight R. Stoll
    Analytical and Bioanalytical Chemistry, 2010, 397 : 979 - 986
  • [39] A New and Fast HPLC Method for Determination of Rutin, Troxerutin, Diosmin and Hesperidin in Food Supplements Using Fused-Core Column Technology
    Satinsky, Dalibor
    Jaegerova, Katerina
    Havlikova, Lucie
    Solich, Petr
    FOOD ANALYTICAL METHODS, 2013, 6 (05) : 1353 - 1360
  • [40] Superficially porous particles with 1000 Å pores for large biomolecule high performance liquid chromatography and polymer size exclusion chromatography
    Wagner, Brian M.
    Schuster, Stephanie A.
    Boyes, Barry E.
    Shields, Taylor J.
    Miles, William L.
    Haynes, Mark J.
    Moran, Robert E.
    Kirkland, Joseph J.
    Schure, Mark R.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1489 : 75 - 85