Fast high performance liquid chromatography separations for proteomic applications using Fused-Core® silica particles

被引:59
|
作者
Schuster, Stephanie A. [1 ]
Boyes, Barry E. [1 ,2 ]
Wagner, Brian M. [1 ]
Kirkland, Joseph J. [1 ]
机构
[1] Adv Mat Technol Inc, Wilmington, DE 19810 USA
[2] Univ Georgia, Complex Carbohydrate Res Ctr, Athens, GA 30602 USA
关键词
Superficially porous particles; Fused-Core particles; Tryptic digests; Peptide separations; Peak capacity; Amyloid peptides; FUSED-CORE PARTICLES; PEPTIDE SEPARATIONS; SHELL PARTICLES; PEAK-CAPACITY; COLUMNS; HPLC; TECHNOLOGY;
D O I
10.1016/j.chroma.2011.07.082
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The separation range of superficially porous particles (Fused-Core (R)) has been extended by design of particles with 160 angstrom pores. These particles show superior kinetics (lower resistance to mass transfer), allowing fast separations of peptides and small proteins (molecular weights of <15,000). The high efficiency and relatively low back pressure of these 2.7 mu m Fused-Core particles has been maintained so that separations can be performed with conventional HPLC instruments. Longer columns can be used for higher resolution of complex mixtures of peptides, such as proteolytic digests. Highly reproducible separations of peptides at elevated temperatures with low pH mobile phases are maintained as a result of a stable bonded stationary phase. The utility of such highly stable materials is exemplified by separations of problematic amyloid peptides at low pH (TFA mobile phase) at an operational temperature of 100 degrees C. To address the issue of poor peptide peak shape in formic acid-containing mobile phases we show that the addition of 10-20 mM ammonium formate improves peak shape, retention and load tolerance of peptides. Use of the Fused-Core particle materials for separations of synthetic peptides and tryptic digests yields peak capacities that are comparable to those obtained using columns packed with sub-2-mu m particles, but with less than one-half of the operating back pressure. A peak capacity of 530 was obtained in 150 min on coupled columns of HALO Peptide ES-C18 with a combined length of 250 mm. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 241
页数:10
相关论文
共 50 条
  • [21] Performance of nanoflow liquid chromatography using core-shell particles: A comparison study
    Liu, Ya
    Sun, Kaiyue
    Shao, Chuyi
    Shi, Xiaohui
    Zeng, Juxing
    Guo, Rui
    Zhang, Bo
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1648
  • [22] Fast Analytical Separations with High-Pressure Liquid Chromatography
    Bender, Trandon A.
    Booth, Jenacee
    Walker, Edward B.
    JOURNAL OF CHEMICAL EDUCATION, 2013, 90 (08) : 1061 - 1063
  • [23] Production of Raw and Ligand-modified Silica Monolith Particles in an Enhanced Scale and their Application in High Performance Liquid Chromatography
    Ali, Ashraf
    Cheong, Won Jo
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2017, 38 (08): : 919 - 927
  • [24] Pushing the performance limits of reversed-phase ultra high performance liquid chromatography with 1.3 μm core-shell particles
    Sanchez, A. Carl
    Friedlander, Gareth
    Fekete, Szabolcs
    Anspach, Jason
    Guillarme, Dvy
    Chitty, Mike
    Farkas, Tivadar
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1311 : 90 - 97
  • [25] Fast HPLC Method for Determination of Fenoxycarb and Permethrin in Antiparasitic Veterinary Shampoo Using Fused-Core Column
    Dalibor Šatínský
    Daniela Kameníčková
    Petr Chocholouš
    Petr Solich
    Chromatographia, 2013, 76 : 1559 - 1564
  • [26] Anion separations for liquid chromatography using propylpyridinium silica as the stationary phase
    Auler, Lucia M. L. A.
    Silva, Cesar R.
    Bottoli, Carla B. G.
    Collins, Carol H.
    TALANTA, 2011, 84 (04) : 1174 - 1179
  • [27] Fast HPLC Method for Determination of Fenoxycarb and Permethrin in Antiparasitic Veterinary Shampoo Using Fused-Core Column
    Satinsky, Dalibor
    Kamenickova, Daniela
    Chocholous, Petr
    Solich, Petr
    CHROMATOGRAPHIA, 2013, 76 (21-22) : 1559 - 1564
  • [28] Capillary ultrahigh-pressure liquid chromatography-mass spectrometry for fast and high resolution metabolomics separations
    Sorensen, Matthew J.
    Kennedy, Robert T.
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1635
  • [29] A Fast Determination of Chlorophylls in Barley Grass Juice Powder Using HPLC Fused-Core Column Technology and HPTLC
    Lucie Havlíková
    Dalibor Šatínský
    Lubomír Opletal
    Petr Solich
    Food Analytical Methods, 2014, 7 : 629 - 635
  • [30] A study of retention characteristics and quality control of nutraceuticals containing resveratrol and polydatin using fused-core column chromatography
    Fibigr, Jakub
    Satinsky, Dalibor
    Solich, Petr
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 120 : 112 - 119