Fast high performance liquid chromatography separations for proteomic applications using Fused-Core® silica particles

被引:59
|
作者
Schuster, Stephanie A. [1 ]
Boyes, Barry E. [1 ,2 ]
Wagner, Brian M. [1 ]
Kirkland, Joseph J. [1 ]
机构
[1] Adv Mat Technol Inc, Wilmington, DE 19810 USA
[2] Univ Georgia, Complex Carbohydrate Res Ctr, Athens, GA 30602 USA
关键词
Superficially porous particles; Fused-Core particles; Tryptic digests; Peptide separations; Peak capacity; Amyloid peptides; FUSED-CORE PARTICLES; PEPTIDE SEPARATIONS; SHELL PARTICLES; PEAK-CAPACITY; COLUMNS; HPLC; TECHNOLOGY;
D O I
10.1016/j.chroma.2011.07.082
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The separation range of superficially porous particles (Fused-Core (R)) has been extended by design of particles with 160 angstrom pores. These particles show superior kinetics (lower resistance to mass transfer), allowing fast separations of peptides and small proteins (molecular weights of <15,000). The high efficiency and relatively low back pressure of these 2.7 mu m Fused-Core particles has been maintained so that separations can be performed with conventional HPLC instruments. Longer columns can be used for higher resolution of complex mixtures of peptides, such as proteolytic digests. Highly reproducible separations of peptides at elevated temperatures with low pH mobile phases are maintained as a result of a stable bonded stationary phase. The utility of such highly stable materials is exemplified by separations of problematic amyloid peptides at low pH (TFA mobile phase) at an operational temperature of 100 degrees C. To address the issue of poor peptide peak shape in formic acid-containing mobile phases we show that the addition of 10-20 mM ammonium formate improves peak shape, retention and load tolerance of peptides. Use of the Fused-Core particle materials for separations of synthetic peptides and tryptic digests yields peak capacities that are comparable to those obtained using columns packed with sub-2-mu m particles, but with less than one-half of the operating back pressure. A peak capacity of 530 was obtained in 150 min on coupled columns of HALO Peptide ES-C18 with a combined length of 250 mm. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 241
页数:10
相关论文
共 50 条
  • [1] Modifying conventional high-performance liquid chromatography systems to achieve fast separations with Fused-Core columns: A case study
    Alexander, A. J.
    Waeghe, T. J.
    Himes, K. W.
    Tomasella, F. P.
    Hooker, T. F.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (32) : 5456 - 5469
  • [2] Fused-core particle technology in high-performance liquid chromatography: An overview
    Joseph J.Kirkland
    Stephanie A.Schuster
    William L.Johnson
    Barry E.Boyes
    Journal of Pharmaceutical Analysis, 2013, 3 (05) : 303 - 312
  • [3] Fast chromatography in the regulated bioanalytical environment: sub-2-μm versus fused-core particles
    Cunliffe, Jennifer M.
    BIOANALYSIS, 2012, 4 (08) : 861 - 863
  • [4] Practical comparison of 2.7 μm fused-core silica particles and porous sub-2 μm particles for fast separations in pharmaceutical process development
    Abrahim, Ahmed
    Al-Sayah, Mohammad
    Skrdla, Peter
    Bereznitski, Yuri
    Chen, Yadan
    Wu, Naijun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 51 (01) : 131 - 137
  • [5] Fast analysis of curcuminoids from turmeric (Curcuma longa L.) by high-performance liquid chromatography using a fused-core column
    Felipe Osorio-Tobon, J.
    Carvalho, Pedro I. N.
    Fernandez Barbero, Gerardo
    Nogueira, Gislaine Chrystina
    Rostagno, Mauricio Ariel
    de Almeida Meireles, Maria Angela
    FOOD CHEMISTRY, 2016, 200 : 167 - 174
  • [6] Comprehensive two-dimensional liquid chromatography separations of pharmaceutical samples using dual Fused-Core columns in the 2nd dimension
    Alexander, Anthony J.
    Ma, Lianjia
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (09) : 1338 - 1345
  • [7] Fast simultaneous determination of prominent polyphenols in vegetables and fruits by reversed phase liquid chromatography using a fused-core column
    Marti, Raul
    Valcarcel, Mercedes
    Manuel Herrero-Martinez, Jose
    Cebolla-Cornejo, Jaime
    Rosello, Salvador
    FOOD CHEMISTRY, 2015, 169 : 169 - 179
  • [8] Core-shell particles: Preparation, fundamentals and applications in high performance liquid chromatography
    Hayes, Richard
    Ahmed, Adham
    Edge, Tony
    Zhang, Haifei
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1357 : 36 - 52
  • [9] Optimization and validation of a high performance liquid chromatography method for rapid determination of sinafloxacin, a novel fluoroquinolone in rat plasma using a fused-core C18-silica column
    Wang, Shuowen
    Wen, Jun
    Cui, Lijun
    Zhang, Xiurong
    Wei, Hua
    Xie, Rui
    Feng, Bo
    Wu, Yutian
    Fan, Guorong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 51 (04) : 889 - 893
  • [10] Kinetic performance comparison of a capillary monolithic and a fused-core column in micro-scale liquid chromatography
    Dioszegi, Tuende A.
    Raynie, Douglas E.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1261 : 107 - 112