Liver hemostasis with high-intensity ultrasound - Repair and healing

被引:31
|
作者
Vaezy, S
Noble, ML
Keshavarzi, A
Paun, M
Prokop, AF
Cornejo, C
Sharar, S
Chi, EY
Crum, LA
Martin, RW
机构
[1] Univ Washington, Appl Phys Lab, Ctr Ind & Med Ultrasound, Seattle, WA 98105 USA
[2] Univ Washington, Dept Surg, Seattle, WA 98195 USA
[3] Univ Washington, Dept Bioengn, Seattle, WA 98105 USA
[4] Univ Washington, Dept Pathol, Seattle, WA 98195 USA
[5] Univ Washington, Dept Anesthesiol, Seattle, WA 98195 USA
关键词
acoustic hemostasis; healing; high-intensity focused ultrasound; liver trauma; survival; therapeutic ultrasound; tissue repair;
D O I
10.7863/jum.2004.23.2.217
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. Previous studies have shown that high-intensity focused ultrasound can effectively control bleeding from injuries of liver, spleen, and blood vessels. This study investigated long-term hemostasis and tissue repair after high-intensity focused ultrasound treatment in liver. Methods. A total of 21 rabbits were randomly assigned to 2 groups: high-intensity focused ultrasound treatment (n = 14) and sham treatment (n = 7). All animals had sterile laparotomy and liver exposure. The high-intensity focused ultrasound-treated animals received liver incisions, 20 to 25 mm long and 4 to 6 mm deep, followed immediately by high-intensity focused ultrasound application until complete hemostasis was achieved. After recovery; sonographic images, blood samples, and histologic samples were collected immediately and on days 1, 3, 7, 14, 28, and 60 after treatment. Results. All 14 liver injuries were hemostatic after an average +/- SD of 78 +/- 44 seconds of high-intensity focused ultrasound application, with no rebleeding at any time point after the treatment. Subsequent blood analysis showed no significant difference in serial hematologic or coagulation measures between the high-intensity focused ultrasound and sham groups. Alanine aminotransferase and aspartate aminotransferase levels increased immediately after surgery by as much as 285% up to day 3 and returned to normal values by day 7. Hematocrit and white blood cell counts showed no statistically significant difference from normal values at all time points. Histologic examination up to 60 days after treatment revealed scarring and liver tissue regeneration at the treatment site. Conclusions. High-intensity focused ultrasound appears to provide long-lasting hemostasis of acute liver injury Healing and repair mechanisms after high-intensity focused ultrasound application appear to be intact.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 50 条
  • [21] High intensity focused ultrasound: A method of hemostasis
    Vaezy, S
    Martin, R
    Crum, L
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (04): : 309 - 315
  • [22] Hemostasis using high intensity focused ultrasound
    Vaezy, Shahram
    Martin, Roy
    Mourad, Pierre
    Crum, Lawrence
    European Journal of Ultrasound, 1999, 9 (01): : 79 - 87
  • [23] Design of a high-intensity ultrasound reactor
    Johansson, Orjan
    Pamidi, Taraka
    Lofqvist, Torbjorn
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [24] Design of high-intensity ultrasound reactor
    Johansson, Orjan
    Lofqvist, Torbjorn
    Pamidi, Taraka Rama Krishna
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [25] High-intensity focussed ultrasound (HIFU)
    Hunold, Peter
    Hoellen, F.
    Beldoch, M. P.
    Eckey, T.
    Bohlmann, M. K.
    GYNAKOLOGISCHE ENDOKRINOLOGIE, 2015, 13 (04): : 238 - 244
  • [26] SYMPOSIUM ON THE APPLICATIONS OF HIGH-INTENSITY ULTRASOUND
    WILTSHIRE, MF
    ULTRASONICS, 1990, 28 (05) : 338 - 338
  • [27] Degassing of milk by high-intensity ultrasound
    Villamiel, M
    Verdurmen, R
    de Jong, P
    MILCHWISSENSCHAFT-MILK SCIENCE INTERNATIONAL, 2000, 55 (03): : 123 - 125
  • [28] High-intensity focused ultrasound and cryotherapy
    Murat, F. J.
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2011, 78 : S11 - S11
  • [29] High-intensity focused ultrasound therapy
    Cheung, Vincent Y. T.
    BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2018, 46 : 74 - 83
  • [30] High-intensity ultrasound in cheese processing
    Scudino, Hugo
    Guimaraes, Jonas T.
    Ramos, Gustavo L. P. A.
    Santillo, Antonella
    Pimentel, Tatiana C.
    Cruz, Adriano G.
    Albenzio, Marzia
    CURRENT OPINION IN FOOD SCIENCE, 2023, 50