Direct and sensitive detection of a human virus by rupture event scanning

被引:148
作者
Cooper, MA
Dultsev, FN
Minson, T
Ostanin, VP
Abell, C
Klenerman, D
机构
[1] Univ Cambridge, Dept Chem, Cambridge CB2 1EW, England
[2] Univ Cambridge, Dept Pathol, Cambridge CB2 1QP, England
基金
英国惠康基金; 英国生物技术与生命科学研究理事会;
关键词
D O I
10.1038/nbt0901-833
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We have developed a sensitive, economical method that directly detects viruses by making use of the interaction between type 1 herpes simplex virus (HSV1) and specific antibodies covalently attached to the oscillating surface of a quartz crystal microbalance (QCM). The virions were detached from the surface by monotonously increasing the amplitude of oscillation of the QCM, while using the QCM to sensitively detect the acoustic noise produced when the interactions were broken. We term this process rupture event scanning (REVS). The method is quantitative over at least six orders of magnitude, and its sensitivity approaches detection of a single virus particle.
引用
收藏
页码:833 / 837
页数:5
相关论文
共 17 条
[1]   A study of primary neuronal infection by mutants of herpes simplex virus type 1 lacking dispensable and non-dispensable glycoproteins [J].
Babic, N ;
Rodger, G ;
Arthur, J ;
Minson, AC .
JOURNAL OF GENERAL VIROLOGY, 1999, 80 :2403-2409
[2]  
Ballantine D.S., 1997, ACOUSTIC WAVE SENSOR, V1st ed., P36, DOI DOI 10.1016/B978-012077460-9/50003-4
[3]   THE USE OF MONOCLONAL-ANTIBODIES TO DIFFERENTIATE ISOLATES OF HERPES-SIMPLEX TYPE-1 AND TYPE-2 BY NEUTRALIZATION AND REVERSE PASSIVE HEMAGGLUTINATION TESTS [J].
BUCKMASTER, EA ;
CRANAGE, MP ;
MCLEAN, CS ;
COOMBS, RRA ;
MINSON, A .
JOURNAL OF MEDICAL VIROLOGY, 1984, 13 (02) :193-202
[4]   Hearing bond breakage. Measurement of bond rupture forces using a quartz crystal microbalance [J].
Dultsev, FN ;
Ostanin, VP ;
Klenerman, D .
LANGMUIR, 2000, 16 (11) :5036-5040
[6]  
Janshoff A, 2000, ANGEW CHEM INT EDIT, V39, P4004, DOI 10.1002/1521-3773(20001117)39:22<4004::AID-ANIE4004>3.0.CO
[7]  
2-2
[8]   Experimental design for kinetic analysis of protein-protein interactions with surface plasmon resonance biosensors [J].
Karlsson, R ;
Falt, A .
JOURNAL OF IMMUNOLOGICAL METHODS, 1997, 200 (1-2) :121-133
[9]   Interaction of laser-generated surface acoustic pulses with fine particles: Surface cleaning and adhesion studies [J].
Kolomenskii, AA ;
Schuessler, HA ;
Mikhalevich, VG ;
Maznev, AA .
JOURNAL OF APPLIED PHYSICS, 1998, 84 (05) :2404-2410
[10]   A NOVEL IMMUNOSENSOR FOR HERPES VIRUSES [J].
KONIG, B ;
GRATZEL, M .
ANALYTICAL CHEMISTRY, 1994, 66 (03) :341-344