Influence of Cone-Beam Computed Tomography Enhancement Filters on Diagnosis of Simulated External Root Resorption

被引:29
作者
de Azevedo Vaz, Sergio Lins [1 ]
Vasconcelos, Taruska Ventorini [1 ]
Neves, Frederico Sampaio [1 ]
de Freitas, Deborah Queiroz [1 ]
Haiter-Neto, Francisco [1 ]
机构
[1] Univ Estadual Campinas, Dept Oral Diag, Piracicaba Dent Sch, UNICAMP,Div Oral Radiol, BR-13414903 Piracicaba, SP, Brazil
关键词
LINEAR MEASUREMENTS; APPROXIMAL CARIES; IMAGE-ENHANCEMENT; DIGITAL IMAGES; EX-VIVO; ABILITY; ACCURACY; LESIONS; SIZE; BONE;
D O I
10.1016/j.joen.2011.10.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to determine if cone-beam computed tomography (CBCT) enhancement filters influence the diagnosis of simulated external root resorption (ERR). Methods: Buccal, mesial, and distal root surfaces of 20 single-rooted premolar teeth were evaluated for the presence or absence of simulated defects. Images were obtained using a Classic i-CAT CBCT device (Imaging Sciences International, Inc, Hatfield, PA) and analyzed by 3 oral radiologists. Evaluations were performed with and without CBCT filters. Accuracy, sensitivity, specificity, and positive and negative predictive values were determined. The McNemar test verified the disagreement between all images versus the gold standard and original images versus images with filters; P values <.05 were considered statistically significant. Inter- and intraobserver agreement was calculated by the kappa test. Results: The means of intra- and interobserver agreement ranged from good to excellent. Sharpen 3 x 3 had the highest sensitivity (0.64), accuracy (0.62), and negative predictive value (0.33). Specificity was the highest (0.56) for S9, Smooth, Smooth 3x3, and Angio Sharpen High filters. Positive predictive values were the highest (0.81) for the Smooth 3x3 and Angio Sharpen High filters. The McNemar test showed statistically significant differences from the gold standard for all images (P<.05) as well as for original images versus images with the Shadow filter (P =.01). The other filters did not show statistically significant differences from the original images. Conclusions: The influence of enhancement CBCT filters on ERR diagnosis is small. The Sharpen 3x3 filter gave the best results and the Shadow filter the worst results. (J Endod 2012;38:305-308)
引用
收藏
页码:305 / 308
页数:4
相关论文
共 22 条
  • [1] In-vitro comparison of 2 cone-beam computed tomography systems and panoramic imaging for detecting simulated canine impaction-induced external root resorption in maxillary lateral incisors
    Alqerban, Ali
    Jacobs, Reinhilde
    Souza, Paulo Couto
    Willems, Guy
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (06) : 764.e1 - 764.e11
  • [2] Assessment of linear measurements of bone for implant sites in the presence of metallic artefacts using cone beam computed tomography and multislice computed tomography
    Cremonini, C. C.
    Dumas, M.
    Pannuti, C. M.
    Neto, J. B. C.
    Cavalcanti, M. G. P.
    Lima, L. A.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (08) : 845 - 850
  • [3] Diagnostic ability of computed tomography to evaluate external root resorption in vitro
    da Silveira, H. L. D.
    Silveira, H. E. D.
    Liedke, G. S.
    Lermen, C. A.
    dos Santos, R. B.
    de Figuleiredo, J. A. P.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (07) : 393 - 396
  • [4] Method to Evaluate Inflammatory Root Resorption by Using Cone Beam Computed Tomography
    Estrela, Carlos
    Bueno, Mike Reis
    Goncalves De Alencar, Ana Helena
    Mattar, Rinaldo
    Valladares Neto, Jose
    Azevedo, Bruno Correa
    De Araujo Estrela, Cyntia Rodrigues
    [J]. JOURNAL OF ENDODONTICS, 2009, 35 (11) : 1491 - 1497
  • [5] Detection and size differentiation of simulated tooth root defects using flat-panel volume computerized tomography (fpVCT)
    Hahn, Wolfram
    Fricke-Zech, Susanne
    Fricke, Julia
    Gruber, Rudolf M.
    Dullin, Christian
    Zapf, Antonia
    Hannig, Christian
    Kubein-Meesenburg, Dietmar
    Sadat-Khonsari, Reza
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (02): : 272 - 278
  • [6] Detection of non-cavitated approximal caries lesions in digital images from seven solid-state receptors with particular focus on task-specific enhancement filters. An ex vivo study in human teeth
    Haiter-Neto, Francisco
    dos Anjos Pontual, Andrea
    Frydenberg, Morten
    Wenzel, Ann
    [J]. CLINICAL ORAL INVESTIGATIONS, 2008, 12 (03) : 217 - 223
  • [7] The effects of digital image enhancement on the detection of vertical root fracture
    Kamburoglu, Kivanc
    Murat, Sema
    Pehlivan, Selcen Yueksel
    [J]. DENTAL TRAUMATOLOGY, 2010, 26 (01) : 47 - 51
  • [8] Observer Ability to Detect Ex Vivo Simulated Internal or External Cervical Root Resorption
    Kamburoglu, Kwanc
    Kursun, Sebnem
    Yuksel, Selcen
    Oztas, Bengi
    [J]. JOURNAL OF ENDODONTICS, 2011, 37 (02) : 168 - 175
  • [9] The current status of cone beam computed tomography imaging in orthodontics
    Kapila, S.
    Conley, R. S.
    Harrell, W. E., Jr.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (01) : 24 - 34
  • [10] Koob A, 2004, AM J DENT, V17, P388