Thermal comfort in offices based on office workers' awareness of discomfort

被引:3
|
作者
Kwon, Suh-hyun [1 ]
Lee, Yoonhee [1 ]
Chun, Chungyoon [1 ]
机构
[1] Yonsei Univ, Dept Interior Architecture & Built Environm, 50 Yonsei Ro, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Thermal discomfort awareness; Thermal complaint; Office; Seasonal difference; Time weighted complaint; BUILDINGS; PRODUCTIVITY; HOT; ENVIRONMENT; COMPLAINTS; BEHAVIOR; IMPACT; JAPAN;
D O I
10.1016/j.buildenv.2022.108851
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aims to investigate the environment and conditions that cause thermal discomfort to occupants in office buildings. We named this thermal discomfort awareness the thermal complaint. To collect thermal complaints, an instrument was developed allowing office workers to actively express their thermal discomfort at any time. This device simultaneously measured the environmental factors of the individual's workspace. Office workers offered thermal complaints in a wide range of thermal environments. The thermal range of Hot complaints and Cold complaints were not separated; however, a difference was observed when the average values were examined. In the summer, the mean temperature for Hot complaints was 28.1 degrees C, and the mean temperature for Cold complaints was 25.8 degrees C. In the winter, the mean temperature for Hot complaints was 25.0 degrees C, and the mean temperature for Cold complaints was 23.1 degrees C. To exclude the effect of time exposed at a certain temperature, the ratio of the complaint frequency to a temperature bin was recalculated to produce a time-weighted complaint (TwC). In summer, TwC values were lowest in the range of 25.0 degrees C-28.0 degrees C. In winter, the overall TwC frequency was lower than in summer, with the lowest between 18.0 degrees C and 28.0 degrees C. This meant that residents showed a wider acceptable temperature range in winter than in summer. In addition, no seasonal differences in TwC were found in the high temperature range above 27.0 degrees C. However, in the lower temperature range, the TwC values were seasonally different. From these results, it can be concluded that the acceptable range based on TwC is 25-28 degrees C in summer and 18-28 degrees C in winter. From the results of this study, if heating and cooling are carried out in the direction of securing acceptability based on discomfort elimination, it will be possible to save a lot of energy by reflecting the seasonal difference.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Thermal comfort and self-reported productivity in an office with ceiling fans in the tropics
    Lipczynska, Aleksandra
    Schiavon, Stefano
    Graham, Lindsay T.
    BUILDING AND ENVIRONMENT, 2018, 135 : 202 - 212
  • [32] A satisfaction-range approach for achieving thermal comfort level in a shared office
    Pazhoohesh, Mehdi
    Zhang, Cheng
    BUILDING AND ENVIRONMENT, 2018, 142 : 312 - 326
  • [33] Assessment of thermal comfort and energy savings in a field study on adaptive comfort with application for mixed mode offices
    Barbadilla-Martin, Elena
    Guadix Martin, Jose
    Salmeron Lissen, Jose Manuel
    Sanchez Ramos, Jose
    Alvarez Dominguez, Servando
    ENERGY AND BUILDINGS, 2018, 167 : 281 - 289
  • [34] Experimental comparison of local direct heating to improve thermal comfort of workers
    Wang, Haiying
    Xu, Manshu
    Bian, Chunxiao
    BUILDING AND ENVIRONMENT, 2020, 177
  • [35] Correlating working performance with thermal comfort, emotion, and fatigue evaluations through on-site study in office buildings
    Liang, Yaowen
    Yu, Jiangpeng
    Xu, Runze
    Zhang, Jingsi
    Zhou, Xiang
    Luo, Maohui
    BUILDING AND ENVIRONMENT, 2024, 265
  • [36] Time spent in the office and workers? productivity, comfort and health: A perception study
    Rasheed, Eziaku Onyeizu
    Khoshbakht, Maryam
    Baird, George
    BUILDING AND ENVIRONMENT, 2021, 195
  • [37] Coupled heat and mass transfer analysis for indoor air quality and thermal comfort in naturally ventilated offices
    Huang, Zhaopeng
    Li, Qiong
    He, Yiyuan
    Ding, Xiang
    Dong, Yunli
    Gao, Wenfeng
    APPLIED THERMAL ENGINEERING, 2025, 269
  • [38] Thermal comfort and productivity in offices under mandatory electricity savings after the Great East Japan earthquake
    Tanabe, Shin-ichi
    Iwahashi, Yuko
    Tsushima, Sayana
    Nishihara, Naoe
    ARCHITECTURAL SCIENCE REVIEW, 2013, 56 (01) : 4 - 13
  • [39] Associations of occupant demographics, thermal history and obesity variables with their thermal comfort in air-conditioned and mixed-mode ventilation office buildings
    Rupp, Ricardo Forgiarini
    Kim, Jungsoo
    de Dear, Richard
    Ghisi, Enedir
    BUILDING AND ENVIRONMENT, 2018, 135 : 1 - 9
  • [40] Thermal Comfort and Adaptive Occupant Behaviour in Open Plan Offices in India and Lithuania
    Tuniki, Himanshu Patel
    Jurelionis, Andrius
    Rupp, Ricardo Forgiarini
    Valancius, Rokas
    Beko, Gabriel
    BUILDINGS, 2025, 15 (05)