Evaluation of fish freshness using impedance spectroscopy based on the characteristic parameter of orthogonal direction difference

被引:8
|
作者
Sun, Jian [1 ,2 ]
Zhang, Rongbiao [1 ]
Zhang, Yecheng [1 ]
Liang, Qiufang [3 ]
Zhang, Fei [1 ]
Xu, Peifeng [2 ]
Li, Guoxiao [1 ]
机构
[1] Jiangsu Univ, Sch Elect & Informat Engn, Zhenjiang, Jiangsu, Peoples R China
[2] Jiangsu Vocat Coll Agr & Forestry, Sch Informat Engn, Zhenjiang, Jiangsu, Peoples R China
[3] Jiangsu Univ, Sch Food & Biol Engn, Zhenjiang, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
fish freshness; TVB-N; impedance spectroscopy; nondestructive testing; orthogonal direction difference; COST NONDESTRUCTIVE SYSTEM; BIOELECTRICAL-IMPEDANCE; SHELF-LIFE; PREDICTION; FAT; QUALITY; STORAGE; BEEF; PORK;
D O I
10.1002/jsfa.10435
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
BACKGROUND As a nondestructive testing technology, electrochemical impedance spectroscopy (EIS) has been applied to evaluate food quality because of its features of rapidity, low cost, nondestructiveness and portability. However, fish freshness evaluation based on existing EIS technology is affected by the differences of individual biological samples. In this study, the difference of electrical properties between two orthogonal directions was extracted to develop a new freshness indicator. A real part orthogonal direction difference parameter set (RODDS) was used to establish a prediction model for total volatile basic nitrogen (TVB-N). RESULTS Compared with the traditional parameter of EIS, coefficient of determination between RODDS and TVB-N increased from 0.55 to 0.71 for the calibration group, and root mean squared error between predicted and measured values of TVB-N decreased from 5.46 to 3.81 for the test group. CONCLUSIONS The results implied that RODDS could effectively offset individual differences in basic electrical properties and improve the TVB-N prediction accuracy in practical application scenarios with samples from multiple origins. The proposed method may provide a new idea for the development and improvement of EIS-based portable testing devices for fish and meat. (c) 2020 Society of Chemical Industry
引用
收藏
页码:4124 / 4131
页数:8
相关论文
共 50 条
  • [31] Using impedance spectroscopy for evaluation of rubber linings used in FGD installations
    Masalski, Jan
    Drela, Izydor
    Piasecki, Tomasz
    Nitsch, Karol
    Szczygiel, Bogdan
    OCHRONA PRZED KOROZJA, 2012, 55 (04): : 185 - 188
  • [32] Evaluation of TGO growth in thermal barrier coatings using impedance spectroscopy
    Huang Hui
    Liu Chao
    Ni Liyong
    Zhou Chungen
    RARE METALS, 2011, 30 : 643 - 646
  • [33] Rapid Assessment of Fish Freshness for Multiple Supply-Chain Nodes Using Multi-Mode Spectroscopy and Fusion-Based Artificial Intelligence
    Zadeh, Hossein Kashani
    Hardy, Mike
    Sueker, Mitchell
    Li, Yicong
    Tzouchas, Angelis
    MacKinnon, Nicholas
    Bearman, Gregory
    Haughey, Simon A.
    Akhbardeh, Alireza
    Baek, Insuck
    Hwang, Chansong
    Qin, Jianwei
    Tabb, Amanda M.
    Hellberg, Rosalee S.
    Ismail, Shereen
    Reza, Hassan
    Vasefi, Fartash
    Kim, Moon
    Tavakolian, Kouhyar
    Elliott, Christopher T.
    SENSORS, 2023, 23 (11)
  • [34] Research on Distinguishing Fish Meal Quality Using Different Characteristic Parameters Based on Electronic Nose Technology
    Li, Pei
    Ren, Zouhong
    Shao, Kaiyi
    Tan, Hequn
    Niu, Zhiyou
    SENSORS, 2019, 19 (09)
  • [35] Assay of fish freshness using trimethylamine vapor probe based on a sensitive membrane on piezoelectric quartz crystal
    Zhao, CZ
    Pan, YZ
    Ma, LZ
    Tang, ZN
    Zhao, GL
    Wang, LD
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 81 (2-3) : 218 - 222
  • [36] Non-destructive evaluation of thermal barrier coatings using impedance spectroscopy
    Wang, X
    Mei, JF
    Xiao, P
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2001, 21 (07) : 855 - 859
  • [37] Development of a new rapid measurement technique for fish embryo membrane permeability studies using impedance spectroscopy
    Zhang, T.
    Wang, R. Y.
    Bao, Q-Y.
    Rawson, D. M.
    THERIOGENOLOGY, 2006, 66 (04) : 982 - 988
  • [38] Fish Freshness Monitoring Using an E-Tongue Based on Polypyrrole Modified Screen-Printed Electrodes
    Apetrei, Irina Mirela
    Luz Rodriguez-Mendez, Maria
    Apetrei, Constantin
    de Saja, Jose A.
    IEEE SENSORS JOURNAL, 2013, 13 (07) : 2548 - 2554
  • [39] Assessment of pork freshness based on changes in constituting chromophores using visible to near-infrared spectroscopy
    Peyvasteh, M.
    Popov, A.
    Bykov, A.
    Meglinski, I.
    BIOPHOTONICS AUSTRALASIA 2019, 2019, 11202
  • [40] NONDESTRUCTIVE EVALUATION OF MOISTURE CONTENT FOR SPINACH LEAF POWDER USING COMPLEX IMPEDANCE SPECTROSCOPY
    Shekhar, Shubhra
    Prasad, Kamlesh
    JOURNAL OF THE ASABE, 2023, 66 (02): : 415 - 421