Impact of surgeon handedness in manual and robot-assisted total hip arthroplasty

被引:23
作者
Kong, Xiangpeng [1 ]
Yang, Minzhi [1 ,2 ]
Li, Xiang [1 ]
Ni, Ming [1 ]
Zhang, Guoqiang [1 ]
Chen, Jiying [1 ]
Chai, Wei [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Orthpaed, 28 Fuxing Rd, Beijing 100853, Peoples R China
[2] Nankai Univ, Med Coll, Tianjin, Peoples R China
关键词
Total hip arthroplasty; Robotic-assisted surgery; Handedness; Acetabular component position; REPLACEMENT;
D O I
10.1186/s13018-020-01671-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The purpose of this study was to examine whether surgeon handedness could affect cup positioning in manual total hip arthroplasty (THA), and whether robot could diminish or eliminate the impact of surgeon handedness on cup positioning in robot-assisted THA. Methods Fifty-three patients who underwent bilateral robot-assisted THA and sixty-two patients who underwent bilateral manual THA between August 2018 and July 2019 in our institute were respectively analyzed in this study. When the difference between the bilateral anteversion and inclination was greater than 5 degrees, the patient was regarded as having different cup positioning between bilateral THA. Their demographics, orientation of acetabular cup, and postoperative 3 month Harris hip score (HHS) were recorded for analysis. Results There were no significant differences in the gender, age, BMI, diagnosis's composition, and preoperative and postoperative HHS between the robotic and manual group. Two left hips dislocated in the manual group. The anteversion of left hip was significantly larger than that of right hip (24.77 +/- 10.44 vs 22.44 +/- 8.67, p = 0.043) in the manual group. There were no significant differences of cup positioning between bilateral robot-assisted THA. The patients in manual group were significantly more likely to have different cup positioning between bilateral hips than those in robotic group (77% vs 45%, p = 0.000). More manual THA were located out of the target zone than robot-assisted THA (70% vs 48%, p = 0.001). Conclusions Surgeon's handedness showed a trend towards an impact on cup positioning in manual THA and robot might help surgeon eliminate the adverse impact. However, the impact of handedness on the clinical outcomes still needs further observation.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Why robot-assisted total hip arthroplasty aborted: Chinese experience of four hundred and twenty nine consecutive cases
    An, Hao-Ming
    Cao, Zheng
    Zhang, Shuai
    Yang, Min-Zhi
    Kong, Xiang-Peng
    Chai, Wei
    [J]. INTERNATIONAL ORTHOPAEDICS, 2024, 48 (09) : 2359 - 2365
  • [22] Robot-Assisted Total Hip Arthroplasty Demonstrates Improved 90-Day Clinical and Patient-Reported Outcomes
    Prinos, Alana
    Buehring, Weston
    Di Gangi, Catherine
    Meere, Patrick
    Meftah, Morteza
    Hepinstall, Matthew
    [J]. ARTHROPLASTY TODAY, 2024, 27
  • [23] A review of the evolution of robotic-assisted total hip arthroplasty
    Subramanian, Padmanabhan
    Wainwright, Tom W.
    Bahadori, Shayan
    Middleton, Robert G.
    [J]. HIP INTERNATIONAL, 2019, 29 (03) : 232 - 238
  • [24] Accuracy of cup position following robot-assisted total hip arthroplasty may be associated with surgical approach and pelvic tilt
    Hayashi, Shinya
    Hashimoto, Shingo
    Kuroda, Yuichi
    Nakano, Naoki
    Matsumoto, Tomoyuki
    Ishida, Kazunari
    Shibanuma, Nao
    Kamenaga, Tomoyuki
    Kuroda, Ryosuke
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [25] Impact of Robotic Assisted Surgery on Outcomes in Total Hip Arthroplasty
    Remily, Ethan A.
    Nabet, Austin
    Sax, Oliver C.
    Douglas, Scott J.
    Pervaiz, Sahir S.
    Delanois, Ronald E.
    [J]. ARTHROPLASTY TODAY, 2021, 9 : 46 - 49
  • [26] Robot-assisted primary cementless total hip arthroplasty using surface registration techniques: a short-term clinical report
    Nakamura, Nobuo
    Sugano, Nobuhiko
    Nishii, Takashi
    Miki, Hidenobu
    Kakimoto, Akihiro
    Yamamura, Mitsuyoshi
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2009, 4 (02) : 157 - 162
  • [27] Precision and accuracy of robot-assisted technology with simplified express femoral workflow in measuring leg length and offset in total hip arthroplasty
    Cozzi Lepri, Andrea
    Villano, Marco
    Innocenti, Matteo
    Porciatti, Tommaso
    Matassi, Fabrizio
    Civinini, Roberto
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2020, 16 (05) : 1 - 6
  • [28] Precise Acetabular Prosthesis Positioning Using a Novel Robot-Assisted Total Hip Arthroplasty System: A Multicenter, Randomized Controlled Trial
    Geng, Xiao
    Dong, Ziyang
    Li, Yang
    Zhao, Minwei
    Liu, Yanqing
    Li, Zijian
    Cai, Hong
    Zhang, Ming
    Yan, Xinfeng
    Sun, Zhiwen
    Lv, Xin
    Guo, Feng
    Li, Feng
    Tian, Hua
    [J]. ORTHOPAEDIC SURGERY, 2024, : 141 - 150
  • [29] Robot-assisted primary cementless total hip arthroplasty using surface registration techniques: a short-term clinical report
    Nobuo Nakamura
    Nobuhiko Sugano
    Takashi Nishii
    Hidenobu Miki
    Akihiro Kakimoto
    Mitsuyoshi Yamamura
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2009, 4 : 157 - 162
  • [30] A Radiological Comparison of Robotic-Assisted Versus Manual Techniques in Total Hip Arthroplasty
    Annapareddy, Adarsh
    Mulpur, Praharsha
    Jayakumar, Tarun
    Shinde, Chethan
    Prasad, Vemaganti Badri Narayana
    Reddy, A. V. Gurava
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2024, 58 (10) : 1423 - 1430