Direct-S: a directed mass spectrometry method for biomarker verification in native serum

被引:1
|
作者
Yin, Hong-Rui [1 ,2 ,3 ,4 ]
Xie, Li-Qi [1 ,2 ]
Xu, Ye [1 ,2 ]
Cai, San-Jun [1 ,2 ]
Yao, Jun [1 ,2 ]
Yang, Peng-Yuan [1 ,2 ,3 ]
Lu, Hao-Jie [1 ,2 ,3 ]
机构
[1] Fudan Univ, Shanghai Canc Ctr, Shanghai 200032, Peoples R China
[2] Fudan Univ, Inst Biomed Sci, Shanghai 200032, Peoples R China
[3] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
[4] Shanghai Inst Food & Drug Control, Shanghai 201203, Peoples R China
基金
美国国家科学基金会;
关键词
LOW-ABUNDANCE PROTEINS; SAMPLE PREPARATION; HUMAN PLASMA; QUANTIFICATION; STRATEGY; IDENTIFICATION; CHROMATOGRAPHY; PROFILES;
D O I
10.1039/c5an00165j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Serum has been the logical choice and most-used bio-specirnen for monitoring biomarkers. However, direct analysis of low-abundance biomarkers in serum is still a problem. Here, we have established a directed mass spectrometry (inclusion list driven MS) method, Direct-S, for direct quantification of protein biomarkers in native serum samples without high-abundance protein depletion or pre-fractionation. In Direct-S, an O-18-labeling technique was used to produce internal standards of the targeted peptides, and only targeted peptides were selected for tandem mass spectrometry (MS/MS) fragmentation to increase sensitivity and efficiency. The O-16/O-18 ion pairs of target peptides and the elution time/fragmental pattern of the internal standards were used to facilitate the identification of the low-abundance peptides. Using Direct-S, three candidate biomarkers, alpha 1-antitrypsin (A1AT), galectin-3 binding protein (LG3BP) and cathepsin D (CTSD), which represent different abundance levels, were quantified in serum samples of colorectal cancer (CRC) patients and healthy candidates. Direct-S exhibited good linearity of response from 20 fmol to 0.5 nmol (r > 0.9845). Reliable quantification across five orders of magnitude and as low as 71 pg mu L-1 was achieved in serum samples. In conclusion, Direct-S is a low cost, convenient and accurate method for verifying serum biomarkers.
引用
收藏
页码:3654 / 3662
页数:9
相关论文
共 50 条
  • [1] Metabolomic study of lipids in serum for biomarker discovery in Alzheimer's disease using direct infusion mass spectrometry
    Gonzalez-Dominguez, R.
    Garcia-Barrera, T.
    Gomez-Ariza, J. L.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 98 : 321 - 326
  • [2] Targeted mass spectrometry approaches for protein biomarker verification
    Meng, Zhaojing
    Veenstra, Timothy D.
    JOURNAL OF PROTEOMICS, 2011, 74 (12) : 2650 - 2659
  • [3] Perspectives of targeted mass spectrometry for protein biomarker verification
    Huettenhain, Ruth
    Malmstroem, Johan
    Picotti, Paola
    Aebersold, Ruedi
    CURRENT OPINION IN CHEMICAL BIOLOGY, 2009, 13 (5-6) : 518 - 525
  • [4] Method verification of serum methylmalonic acid by liquid chromatography tandem mass spectrometry
    Almutairi, F.
    Almutairi, M.
    Nasibah, F.
    CLINICA CHIMICA ACTA, 2024, 558
  • [5] Analysis of mass spectrometry data for serum biomarker discovery
    Ressom, Habtom W.
    Varghese, Rency S.
    Goldman, Lenka
    Loffredo, Christopher A.
    Abdel-Hamid, Mohamed
    Kyselova, Zuzana
    Mechref, Yehia
    Novotny, Milos
    Goldman, Radoslav
    2007 IEEE/NIH LIFE SCIENCE SYSTEMS AND APPLICATIONS WORKSHOP, 2007, : 172 - +
  • [6] Direct characterization of overproduced proteins by native mass spectrometry
    Vimer, Shay
    Ben-Nissan, Gili
    Sharon, Michal
    NATURE PROTOCOLS, 2020, 15 (02) : 236 - 265
  • [7] Direct characterization of overproduced proteins by native mass spectrometry
    Shay Vimer
    Gili Ben-Nissan
    Michal Sharon
    Nature Protocols, 2020, 15 : 236 - 265
  • [8] Using direct infusion mass spectrometry for serum metabolomics in Alzheimer’s disease
    R. González-Domínguez
    T. García-Barrera
    J. L. Gómez-Ariza
    Analytical and Bioanalytical Chemistry, 2014, 406 : 7137 - 7148
  • [9] Using direct infusion mass spectrometry for serum metabolomics in Alzheimer's disease
    Gonzalez-Dominguez, R.
    Garcia-Barrera, T.
    Gomez-Ariza, J. L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (28) : 7137 - 7148
  • [10] Serum Biomarker Identification by Mass Spectrometry in Acute Aortic Dissection
    Ren, Yong
    Tang, Qizhu
    Liu, Wenwei
    Tang, Yongqian
    Zhu, Rui
    Li, Bin
    CELLULAR PHYSIOLOGY AND BIOCHEMISTRY, 2017, 44 (06) : 2147 - 2157