共 50 条
Fatigue resistance of monolithic CAD/CAM ceramic crowns on human premolars
被引:37
作者:
Homaei, Ehsan
[1
,5
]
Farhangdoost, Khalil
[1
,5
]
Pow, Edmond Ho Nang
[2
,6
]
Matinlinna, Jukka Pekka
[3
,6
]
Akbari, Majid
[4
]
Tsoi, James Kit-Hon
[3
,6
]
机构:
[1] Ferdowsi Univ Mashhad, Dept Mech Engn, Mashhad, Iran
[2] Univ Hong Kong, Oral Rehabil, Fac Dent, Hong Kong, Hong Kong, Peoples R China
[3] Univ Hong Kong, Dent Mat Sci, Fac Dent, Hong Kong, Hong Kong, Peoples R China
[4] Mashhad Univ Med Sci, Dent Res Ctr, Fac Dent, Azadi Sq, Mashhad, Iran
[5] Ferdowsi Univ Mashhad, Dept Mech Engn, Fac Engn, Azadi Sq, Mashhad, Iran
[6] Prince Philip Dent Hosp, 4-F,34 Hosp Rd, Hong Kong, Hong Kong, Peoples R China
关键词:
Dental crowns;
CAD/CAM ceramics;
Cerec;
Fatigue;
Lithium disilicate;
Polymer infiltrated ceramics;
COMPOSITE RESIN;
FRACTURE-RESISTANCE;
FAILURE MODES;
VENEERING PORCELAIN;
OCCLUSAL VENEERS;
NETWORK MATERIAL;
CYCLIC FATIGUE;
DENTAL CROWNS;
CAD-CAM;
RESTORATIONS;
D O I:
10.1016/j.ceramint.2016.07.029
中图分类号:
TQ174 [陶瓷工业];
TB3 [工程材料学];
学科分类号:
0805 ;
080502 ;
摘要:
The aim of this study was to determine the fatigue strength of two contemporary crown ceramics, lithium disilicate e.max (R) CAD (LD) and polymer-infiltrated ceramic Enamic (R) (PIC) and examine their failure mode. Twenty extracted human maxillary premolars were divided into two groups. The teeth were prepared and restored with either LD or PIC crowns. The restored teeth were subjected to cyclic chewing simulation (9 Hz). The sinusoidal loading was started with 500 N followed by a stepwise increase of 100 N for every 100,000 cycles until fracture occurred or, alternatively, after one million cycles. The Kaplan-Meier survival analysis was applied on fatigue loadings. Differences in the failure modes were analyzed by Fisher Exact tests. The average failure load of LD group was 1400 N (904,728 cycles) with 70% survival rate, while the average failure load of PIC group was 870 N (378,167 cycles) with 0% survival. Regarding the failure mode in both test groups, the crowns tended to fail above the cementoenamel junction (CEJ) and both combined adhesive and cohesive failure mode were commonly observed rather than cohesive failure. No significant difference was found between the test groups. The failures were initiated from a contact point or central fossa. The fatigue resistance of LD crowns on premolars was significantly higher than the PIC ceramic crowns. (C) 2016 Elsevier Ltd and Techna Group S.r.l. All rights reserved.
引用
收藏
页码:15709 / 15717
页数:9
相关论文
共 50 条