Iterative reconstruction and deep learning algorithms for enabling low-dose computed tomography in midfacial trauma

被引:10
|
作者
Rozema, Romke [1 ]
Kruitbosch, Herbert T. [2 ]
van Minnen, Baucke [1 ]
Dorgelo, Bart [3 ,4 ]
Kraeima, Joep [1 ]
van Ooijen, Peter M. A. [5 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Oral & Maxillofacial Surg, Hanzepl 1, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Ctr Informat Technol, Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Radiol, Groningen, Netherlands
[4] Martini Hosp, Dept Radiol, Groningen, Netherlands
[5] Univ Groningen, Univ Med Ctr Groningen, Dept Radiat Oncol, Groningen, Netherlands
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY | 2021年 / 132卷 / 02期
关键词
IMAGE QUALITY; CT; REDUCTION;
D O I
10.1016/j.oooo.2020.11.018
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The objective of this study was to quantitatively assess the image quality of Advanced Modeled Iterative Reconstruction (ADMIRE) and the PixelShine (PS) deep learning algorithm for the optimization of low-dose computed tomography protocols in mid-facial trauma. Study Design. Six fresh frozen human cadaver head specimens were scanned by computed tomography using both standard and low-dose scan protocols. Three iterative reconstruction strengths were applied to reconstruct bone and soft tissue data sets and these were subsequently applied to the PS algorithm. Signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated for each data set by using the image noise measurements of 10 consecutive image slices from a standardized region of interest template. Results. The low-dose scan protocol resulted in a 61.7% decrease in the radiation dose. Radiation dose reduction significantly reduced, and iterative reconstruction and the deep learning algorithm significantly improved, the CNR for bone and soft tissue data sets. The algorithms improved image quality after substantial dose reduction. The greatest improvement in SNRs and CNRs was found using the iterative reconstruction algorithm. Conclusion. Both the ADMIRE and PS algorithms significantly improved image quality after substantial radiation dose reduction. (Oral Surg Oral Med Oral Pathol Oral Radiol 2021;132:247-254)
引用
收藏
页码:247 / 254
页数:8
相关论文
共 50 条
  • [1] Deep learning image reconstruction for pancreatic low-dose computed tomography: comparison with hybrid iterative reconstruction
    Yoshifumi Noda
    Yukako Iritani
    Nobuyuki Kawai
    Toshiharu Miyoshi
    Takuma Ishihara
    Fuminori Hyodo
    Masayuki Matsuo
    Abdominal Radiology, 2021, 46 : 4238 - 4244
  • [2] Deep learning image reconstruction for pancreatic low-dose computed tomography: comparison with hybrid iterative reconstruction
    Noda, Yoshifumi
    Iritani, Yukako
    Kawai, Nobuyuki
    Miyoshi, Toshiharu
    Ishihara, Takuma
    Hyodo, Fuminori
    Matsuo, Masayuki
    ABDOMINAL RADIOLOGY, 2021, 46 (09) : 4238 - 4244
  • [3] Deep learning reconstruction computed tomography with low-dose imaging
    Tamura, Akio
    Ota, Yoshitaka
    Yoshioka, Kunihiro
    PEDIATRIC RADIOLOGY, 2024, 54 (08) : 1410 - 1410
  • [4] LOW-DOSE COMPUTED TOMOGRAPHY OF THE PARANASAL SINUSES: PERFORMANCE OF TWO DIFFERENT ITERATIVE RECONSTRUCTION ALGORITHMS
    Schaafs, Lars-Arne
    Pfeil, Julian
    Koehlitz, Torsten
    Hamm, Bernd
    Niehues, Stefan Markus
    RADIATION PROTECTION DOSIMETRY, 2019, 183 (03) : 386 - 392
  • [5] VARIATIONAL DEEP LEARNING FOR LOW-DOSE COMPUTED TOMOGRAPHY
    Kobler, Erich
    Muckley, Matthew
    Chen, Baiyu
    Knoll, Florian
    Hammernik, Kerstin
    Pock, Thomas
    Sodickson, Daniel
    Otazo, Ricardo
    2018 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2018, : 6687 - 6691
  • [6] Low-Dose Unenhanced Computed Tomography with Iterative Reconstruction for Diagnosis of Ureter Stones
    Chi, Byung Hoon
    Chang, In Ho
    Lee, Dong Hoon
    Park, Sung Bin
    Kim, Kyung Do
    Moon, Young Tae
    Hur, Taekyu
    YONSEI MEDICAL JOURNAL, 2018, 59 (03) : 389 - 396
  • [7] Low-Dose Carotid Computed Tomography Angiography Using Pure Iterative Reconstruction
    Moloney, Fiachra
    Murphy, Kevin P.
    Twomey, Maria
    Crush, Lee
    Canniffe, Emma M.
    McLaughlin, Patrick D.
    Moore, Niamh
    O'Keeffe, Michael
    O'Neill, Siobhan
    Manning, Brian M.
    Wyse, Gerald
    Fanning, Noel
    O'Connor, Owen J.
    Maher, Michael M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (05) : 833 - 839
  • [8] Computed Tomography in Cystic Fibrosis: Combining Low-Dose Techniques and Iterative Reconstruction
    Kahn, Johannes
    Kaul, David
    Grupp, Ulrich
    Boening, Georg
    Renz, Diane
    Staab, Doris
    Schreiter, Vera
    Streitparth, Florian
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (04) : 668 - 674
  • [9] Low-dose computed tomography scheme incorporating residual learning-based denoising with iterative reconstruction
    Ding, Yong
    Hu, Tuo
    ELECTRONICS LETTERS, 2019, 55 (04) : 174 - 175
  • [10] The use of deep learning methods in low-dose computed tomography image reconstruction: a systematic review
    Minghan Zhang
    Sai Gu
    Yuhui Shi
    Complex & Intelligent Systems, 2022, 8 : 5545 - 5561