DC-link current estimation for load-side converter of brushless doubly-fed generator in the current feed-forward control

被引:15
|
作者
Wang, Xingwei [1 ]
Lin, Hua [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan, Peoples R China
关键词
brushless machines; electric current control; machine control; AC-DC power convertors; PWM power convertors; voltage control; stability; DC generators; load-side converter; brushless doubly-fed generator; current feed-forward control; BDFG control system; back-to-back converter; machine-side converter; MSC; LSC; three-phase AC-DC pulse width modulation converter; double-loop control strategy; outer voltage loop; inner current loop; load disturbance; complex harmonic spectrum; DC-link current estimation algorithm; equivalent circuit; CONTROL SCHEME; PWM CONVERTER; EQUIVALENT-CIRCUIT; INVERTER SYSTEM; FED MACHINES; PERFORMANCE; RECTIFIER; MODEL; CAPACITOR;
D O I
10.1049/iet-pel.2015.0910
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the stand-alone brushless doubly-fed generator (BDFG) control system, there are two back-to-back converters composed of the machine-side converter (MSC) and the load-side converter (LSC). The LSC is a three-phase AC-DC pulse width modulation converter which usually adopts the double-loop control strategy with outer voltage loop and inner current loop. The introduction of the DC-link current feed-forward for improving the dynamic performance of the LSC can reduce the effect of the load disturbance to the system. However, the DC-link current has a complex harmonic spectrum with the MSC connected to the DC side, so its average value is not convenient to measure. This study presents a DC-link current estimation algorithm for the current feed-forward control in the LSC of the stand-alone BDFG. With the help of the equivalent circuit of the BDFG and the power balance, the rapid calculation of the average DC-link current can be estimated as well. With this estimation of the current instead of the actual DC-link current, the DC-link voltage and AC side current of the LSC can achieve stability quickly. The effectiveness and correction is validated by the simulation and experiments.
引用
收藏
页码:1703 / 1710
页数:8
相关论文
共 30 条
  • [21] DC-Link Capacitor Design in Neutral Point Clamped Multilevel Inverter Utilizing Ripple Current Analysis and DC-DC Converter Control
    Sholihah, Fifi Hesty
    Becerra, Victor
    Prabhu, Shanker Radhakrishna
    2024 INTERNATIONAL ELECTRONICS SYMPOSIUM, IES 2024, 2024, : 89 - 94
  • [22] Phase Current Reconstruction and Control of Three-Phase Switched Reluctance Machine With Modular Power Converter Using Single DC-Link Current Sensor
    Song, Shoujun
    Xia, Zekun
    Fang, Gaoliang
    Ma, Ruiqing
    Liu, Weiguo
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (10) : 8637 - 8649
  • [23] Unified DC-Link Current Control for Low-Voltage Ride-Through in Current-Source-Converter-Based Wind Energy Conversion Systems
    Dai, Jingya
    Xu, Dewei
    Wu, Bin
    Zargari, Navid R.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (01) : 288 - 297
  • [24] Control Strategy of Electrolytic Capacitor-Less Multi-Port Converter for Suppressing the Influences of Low-Frequency DC-Link Current Ripple
    Fang, Zhijian
    Wu, Chenhui
    Zhang, Zihong
    Xiao, Liangle
    Xia, Yuangeng
    Dong, Hanlin
    Yue, Haojiang
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (06) : 8548 - 8562
  • [25] Energy control of on-grid hybrid wind/PV power system using doubly fed induction generator-direct current link topology
    Touaiti, Bilel
    Ben Azza, Hechmi
    Abdelkader, Abbassi
    Abbassi, Rabeh
    Farah, Anouar
    Jemli, Mohamed
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2021, : 8611 - 8627
  • [26] Current Stress Optimized Strategy for the Dual-Active-Bridge Converter With Triple-Phase-Shift and Variable DC-Link Voltage Control
    Yan, Yipeng
    Luo, Quanming
    Luo, Ting
    Li, Jia
    Xiong, Jianglin
    Xiao, Hang
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (06) : 8344 - 8355
  • [27] Impact of Dead Time on Inverter Input Current, DC-Link Dynamics, and Light-Load Instability in Rectifier-Inverter-Fed Induction Motor Drives
    Guha, Anirudh
    Narayanan, G.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (02) : 1414 - 1424
  • [28] Comparison of Advanced Control Techniques for Grid Side Converter of Doubly-Fed Induction Generator Back-to-Back Converters to Improve Power Quality Performance During Unbalanced Voltage Dips
    Baggu, Murali M.
    Chowdhury, Badrul H.
    Kimball, Jonathan W.
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2015, 3 (02) : 516 - 524
  • [29] A Direct Actual-Power Control Scheme for Current-Fed Dual-Active-Bridge DC/DC Converter Based on Virtual Impedance Estimation
    Zhang, Yue
    Ding, Li
    Hou, Nie
    Li, Yunwei
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (08) : 8963 - 8975
  • [30] Negative-Sequence Current Compensation-Based Coordinated Control Strategy for Dual-Cage-Rotor Brushless Doubly Fed Induction Generator Under Unbalanced Grid Conditions
    Cheng, Ming
    Yan, Xiaoming
    Zhou, Jiawei
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (05) : 4762 - 4773