Immuno-based sample preparation for trace analysis

被引:190
作者
Hennion, MC [1 ]
Pichon, V [1 ]
机构
[1] Ecole Super Phys & Chim Ind Ville Paris, UMR CNRS 7121, Lab Environm & Chim Analyt, F-75231 Paris 05, France
关键词
reviews; immunoaffinity extraction; solid-phase extraction; sample preparation; molecular imprinting; immunoextraction; immunofiltration; SOLID-PHASE EXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; LIQUID-CHROMATOGRAPHIC ANALYSIS; IMMUNOAFFINITY COLUMN CLEANUP; MOLECULARLY IMPRINTED POLYMER; OCHRATOXIN-A; CAPILLARY-ELECTROPHORESIS; GAS-CHROMATOGRAPHY; AFFINITY-CHROMATOGRAPHY; SELECTIVE ENRICHMENT;
D O I
10.1016/S0021-9673(03)00529-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Immuno-based sample preparation techniques are based upon molecular recognition. Thanks to the high affinity and high selectivity of the antigen-antibody interaction, they have been shown to be a unique tool in the sampling area. Immuno-based sample preparation methods include the widely encountered immunoaffinity extraction sorbents, so-called immunosorbents, as well as membrane-based or ultratiltration techniques. This review describes the new developments and applications that have occurred in recent years with emphasis on (i) the antigen-antibody interactions, (ii) and their importance for the properties and use of immunosorbents, (iii) multiresidue extractions, (iv) the on-line coupling to chromatographic or electrophoretic separations, and (v) the high potential for improving MS detection. The recent use of artificial antibodies for sample pretreatment, so-called molecularly imprinted polymers, is also described. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:29 / 52
页数:24
相关论文
共 110 条
[1]   Immunochemical approaches for purification and detection of TNT traces by antibodies entrapped in a sol-gel matrix [J].
Altstein, M ;
Bronshtein, A ;
Glattstein, B ;
Zeichner, A ;
Tamiri, T ;
Almog, J .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2461-2467
[2]   Molecularly imprinted solid-phase extraction sorbent for the clean-up of chlorinated phenoxyacids from aqueous samples [J].
Baggiani, C ;
Giovannoli, C ;
Anfossi, L ;
Tozzi, C .
JOURNAL OF CHROMATOGRAPHY A, 2001, 938 (1-2) :35-44
[3]   Influence of the hapten design on the development of a competitive ELISA for the determination of the antifouling agent Irgarol 1051 at trace levels [J].
Ballesteros, B ;
Barceló, D ;
Sanchez-Baeza, F ;
Camps, F ;
Marco, MP .
ANALYTICAL CHEMISTRY, 1998, 70 (19) :4004-4014
[4]   Detection of polycyclic aromatic hydrocarbon metabolites by high-pressure liquid chromatography after purification on immunoaffinity columns in urine from occupationally exposed workers [J].
Bentsen-Farmen, RK ;
Botnen, IV ;
Noto, H ;
Jacob, J ;
Ovrebo, S .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1999, 72 (03) :161-168
[5]   Use of molecularly imprinted solid-phase extraction for the selective clean-up of clenbuterol from calf urine [J].
Berggren, C ;
Bayoudh, S ;
Sherrington, D ;
Ensing, K .
JOURNAL OF CHROMATOGRAPHY A, 2000, 889 (1-2) :105-110
[6]   On-line solid-phase extraction of triazine herbicides using a molecularly imprinted polymer for selective sample enrichment [J].
Bjarnason, B ;
Chimuka, L ;
Ramström, O .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2152-2156
[7]   On-line coupling of immunosorbent and liquid chromatographic analysis for the selective extraction and determination of polycyclic aromatic hydrocarbons in water samples at the ng 1-1 level [J].
Bouzige, M ;
Pichon, V ;
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) :197-210
[8]   Class-selective immunosorbent for trace-level determination of polycyclic aromatic hydrocarbons in complex sample matrices, used in off-line procedure or on-line coupled with liquid chromatography fluorescence and diode array detections in series [J].
Bouzige, M ;
Pichon, V ;
Hennion, MC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (11) :1916-1925
[9]   Selective on-line immunoextraction coupled to liquid chromatography for the trace determination of benzidine, congeners and related azo dyes in surface water and industrial effluents [J].
Bouzige, M ;
Legeay, P ;
Pichon, V ;
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 846 (1-2) :317-329
[10]  
BOUZIGE M, 2000, THESIS U PARIS 6