Modular Preoperative Planning Software for Computer-Aided Oral Implantology and the Application of a Novel Stereolithographic Template: A Pilot Study

被引:39
作者
Chen, Xiaojun [1 ]
Yuan, Jianbing [1 ]
Wang, Chengtao [1 ]
Huang, Yuanliang [2 ]
Kang, Lu [2 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Biomed Mfg & Life Qual Engn, Shanghai 200030, Peoples R China
[2] Tongji Univ, Shanghai E Hosp, Shanghai 200092, Peoples R China
基金
中国博士后科学基金;
关键词
computer-aided surgery; oral implantology; preoperative planning; stereolithographic template; PLACEMENT; ACCURACY; NAVIGATION; GUIDES; MODEL; FORM;
D O I
10.1111/j.1708-8208.2009.00160.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: In the field of oral implantology, there is a trend toward computer-aided implant surgery, especially the application of computerized tomography (CT)-derived surgical templates. However, because of relatively unsatisfactory match between the templates and receptor sites, conventional surgical templates may not be accurate enough for the severely resorbed edentulous cases during the procedure of transferring the preoperative plan to the actual surgery. The purpose of this study is to introduce a novel bone-tooth-combined-supported surgical guide, which is designed by utilizing a special modular software and fabricated via stereolithography technique using both laser scanning and CT imaging, thus improving the fit accuracy and reliability. Materials and Methods: A modular preoperative planning software was developed for computer-aided oral implantology. With the introduction of dynamic link libraries and some well-known free, open-source software libraries such as Visualization Toolkit (Kitware, Inc., New York, USA) and Insight Toolkit (Kitware, Inc.) a plug-in evolutive software architecture was established, allowing for expandability, accessibility, and maintainability in our system. To provide a link between the preoperative plan and the actual surgery, a novel bone-tooth-combined-supported surgical template was fabricated, utilizing laser scanning, image registration, and rapid prototyping. Clinical studies were conducted on four partially edentulous cases to make a comparison with the conventional bone-supported templates. Results: The fixation was more stable than tooth-supported templates because laser scanning technology obtained detailed dentition information, which brought about the unique topography between the match surface of the templates and the adjacent teeth. The average distance deviations at the coronal and apical point of the implant were 0.66 mm (range: 0.3-1.2) and 0.86 mm (range: 0.4-1.2), and the average angle deviation was 1.84 degrees (range: 0.6-2.8 degrees). Conclusions: This pilot study proves that the novel combined-supported templates are superior to the conventional ones. However, more clinical cases will be conducted to demonstrate their feasibility and reliability.
引用
收藏
页码:181 / 193
页数:13
相关论文
共 33 条
[1]   LEAST-SQUARES FITTING OF 2 3-D POINT SETS [J].
ARUN, KS ;
HUANG, TS ;
BLOSTEIN, SD .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) :699-700
[2]  
ASKARY AS, 1999, IMPLANT DENT, V8, P265
[3]  
Balshi Stephen F, 2006, J Esthet Restor Dent, V18, P312, DOI 10.1111/j.1708-8240.2006.00029.x
[4]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[5]   Accuracy of image-guided implantology [J].
Brief, J ;
Edinger, D ;
Hassfeld, S ;
Eggers, G .
CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) :495-501
[6]  
Brief J, 2001, Int Congr Ser, V1230, P739
[7]   Extending surfaces for reverse engineering solid model generation [J].
Chivate, PN ;
Puntambekar, NV ;
Jablokow, AG .
COMPUTERS IN INDUSTRY, 1999, 38 (03) :285-294
[8]  
Di Giacomo GAP, 2005, J PERIODONTOL, V76, P503
[9]  
el Askary A S, 1999, Implant Dent, V8, P173
[10]   Presurgic planning with CT-derived fabrication of surgical guides [J].
Ganz, SD .