A photoacoustic finder fully integrated with a solid-state dye laser and transparent ultrasound transducer

被引:56
作者
Park, Byullee [1 ,2 ]
Han, Moongyu [1 ,2 ]
Park, Jeongwoo [1 ,2 ]
Kim, Taejeong [3 ]
Ryu, Hanyoung [4 ]
Seo, Youngseok [4 ]
Kim, Won Jong [3 ]
Kim, Hyung Ham [1 ,2 ]
Kim, Chulhong [1 ,2 ]
机构
[1] Pohang Univ Sci & Technol, Dept Elect Engn, Convergence IT Engn, Mech Engn, 77 Cheongam Ro, Pohang 37673, South Korea
[2] Pohang Univ Sci & Technol, Sch Interdisciplinary Biosci & Bioengn, Med Device Innovat Ctr, 77 Cheongam Ro, Pohang 37673, South Korea
[3] Pohang Univ Sci & Technol, Sch Interdisciplinary Biosci & Bioengn, Postech Catholic Biomed Engn Inst, Dept Chem, 77 Cheongam Ro, Pohang 37673, South Korea
[4] Wontech Co Ltd, R&D Ctr, Daejeon 34028, South Korea
基金
新加坡国家研究基金会;
关键词
Photoacoustic sensing; Transparent ultrasound transducer; Solid-state dye laser; Melanoma; Sentinel lymph node; LYMPH-NODE BIOPSY; INDOCYANINE GREEN FLUORESCENCE; BREAST-CANCER; RADIOISOTOPE; EXPANSION; PROBE;
D O I
10.1016/j.pacs.2021.100290
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The standard-of-care for evaluating lymph node status in breast cancers and melanoma metastasis is sentinel lymph node (SLN) assessment performed with a handheld gamma probe and radioisotopes. However, this method inevitably exposes patients and physicians to radiation, and the special facilities required limit its accessibility. Here, we demonstrate a non-ionizing, cost-effective, handheld photoacoustic finder (PAF) fully integrated with a solid-state dye laser and transparent ultrasound transducer (TUT). The solid-state dye laser handpiece is coaxially aligned with the spherically focused TUT. The integrated finder readily detected photo acoustic signals from a tube filled with methylene blue (MB) beneath a 22 mm thick layer of chicken tissue. In live animals, we also photoacoustically detected both SLNs injected with MB and subcutaneously injected melanomas. We believe that our radiation-free and inexpensive PAF can play a vital role in SLN assessment.
引用
收藏
页数:7
相关论文
共 59 条
[11]   Sentinel lymph node biopsy as the new standard of care in the surgical treatment for breast cancer [J].
Ferrari, Alberta ;
Rovera, Francesca ;
Dionigi, Paolo ;
Limonta, Giorgio ;
Marelli, Marina ;
Besana Ciani, Isabella ;
Bianchi, Veronica ;
Vanoli, Cristiana ;
Dionigi, Renzo .
EXPERT REVIEW OF ANTICANCER THERAPY, 2006, 6 (10) :1503-1515
[12]   Dual-Modality Photoacoustic and Ultrasound Imaging System for Noninvasive Sentinel Lymph Node Detection in Patients with Breast Cancer [J].
Garcia-Uribe, Alejandro ;
Erpelding, Todd N. ;
Krumholz, Arie ;
Ke, Haixin ;
Maslov, Konstantin ;
Appleton, Catherine ;
Margenthaler, Julie A. ;
Wang, Lihong V. .
SCIENTIFIC REPORTS, 2015, 5
[13]   In Vivo Dual-Modal Photoacoustic and Ultrasound Imaging of Sentinel Lymph Nodes Using a Solid-State Dye Laser System [J].
Han, Moongyu ;
Choi, Wonseok ;
Ahn, Joongho ;
Ryu, Hanyoung ;
Seo, Youngseok ;
Kim, Chulhong .
SENSORS, 2020, 20 (13) :1-12
[14]   Towards non-contact photoacoustic imaging [review] [J].
Hosseinaee, Zohreh ;
Le, Martin ;
Bell, Kevan ;
Reza, Parsin Haji .
PHOTOACOUSTICS, 2020, 20
[15]   Real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans [J].
Jeon, Seungwan ;
Park, Eun-Yeong ;
Choi, Wonseok ;
Managuli, Ravi ;
Lee, Ki Jong ;
Kim, Chulhong .
PHOTOACOUSTICS, 2019, 15
[16]   A Novel 2-D Synthetic Aperture Focusing Technique for Acoustic-Resolution Photoacoustic Microscopy [J].
Jeon, Seungwan ;
Park, Jihoon ;
Managuli, Ravi ;
Kim, Chulhong .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (01) :250-260
[17]   In Vivo Photoacoustic Imaging of Anterior Ocular Vasculature: A Random Sample Consensus Approach [J].
Jeon, Seungwan ;
Song, Hyun Beom ;
Kim, Jaewoo ;
Lee, Byung Joo ;
Managuli, Ravi ;
Kim, Jin Hyoung ;
Kim, Jeong Hun ;
Kim, Chulhong .
SCIENTIFIC REPORTS, 2017, 7
[18]   A Peptide Probe Enables Photoacoustic-Guided Imaging and Drug Delivery to Lung Tumors in K-rasLA2 Mutant Mice [J].
Jung, Hyunkyung ;
Park, Sungjo ;
Gunassekaran, Gowri Rangaswamy ;
Jeon, Mansik ;
Cho, Young-Eun ;
Baek, Moon-Chang ;
Park, Jae Yong ;
Shim, Gayong ;
Oh, Yu-Kyoung ;
Kim, In-San ;
Kim, Chulhong ;
Lee, Byungheon .
CANCER RESEARCH, 2019, 79 (16) :4271-4282
[19]   Comparison of Sentinel Lymph Node Biopsy Guided by the Multimodal Method of Indocyanine Green Fluorescence, Radioisotope, and Blue Dye Versus the Radioisotope Method in Breast Cancer: A Randomized Controlled Trial [J].
Jung, So-Youn ;
Kim, Seok-Ki ;
Kim, Seok Won ;
Kwon, Youngmee ;
Lee, Eun Sook ;
Kang, Han-Sung ;
Ko, Kyoung Lan ;
Shin, Kyung Hwan ;
Lee, Keun Seok ;
Park, In Hae ;
Ro, Jungsil ;
Jeong, Hae Jeong ;
Joo, Jungnam ;
Kang, Se Hun ;
Lee, Seeyoun .
ANNALS OF SURGICAL ONCOLOGY, 2014, 21 (04) :1254-1259
[20]   Breast cancer detection using automated whole breast ultrasound and mammography in radiographically dense breasts [J].
Kelly, Kevin M. ;
Dean, Judy ;
Comulada, W. Scott ;
Lee, Sung-Jae .
EUROPEAN RADIOLOGY, 2010, 20 (03) :734-742