Cardiac Output Measurement Using the Ultrasonic Cardiac Output Monitor: A Validation Study in Newborn Infants

被引:13
作者
Fraga, Maria, V [1 ]
Dysart, Kevin C. [1 ]
Rintoul, Natalie [1 ]
Chaudhary, Aasma S. [2 ]
Ratcliffe, Sarah J. [3 ]
Fedec, Anysia [4 ]
Kren, Stephanie [4 ]
Cohen, Meryl S. [4 ]
Kirpalani, Haresh [1 ]
机构
[1] Childrens Hosp Philadelphia, Dept Pediat, Div Neonatol, Philadelphia, PA 19104 USA
[2] Univ Penn, Hosp Univ Penn, Div Neonatol, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Biostat & Epidemiol, Perelman Sch Med, Philadelphia, PA 19104 USA
[4] Childrens Hosp Philadelphia, Dept Pediat, Div Cardiol, Philadelphia, PA 19104 USA
关键词
Ultrasonic Cardiac Output Monitor; Cardiac output; Newborn infants; VENTRICULAR OUTPUT; CHILDREN; COMPLICATIONS; REPEATABILITY;
D O I
10.1159/000501005
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objectives: We aimed to determine the accuracy and validity of the Ultrasonic Cardiac Output Monitor (USCOM) measurements of cardiac output (CO) compared to echocardiography in newborn infants, and the inter-rater agreement of USCOM measurements. Methods: In a single-center study we prospectively evaluated neonates undergoing an echocardiographic evaluation. USCOM measurements of CO were obtained at the pulmonary and aortic valve by 2 physicians blinded to the echocardiographic results. All echocardiographic measurements were performed blinded to USCOM measurements. We first enrolled an ascertainment cohort which was subsequently validated in an independent new cohort. Agreement between echocardiography and USCOM methods was assessed by Bland-Altman analysis. Intra-class correlation coefficients (ICC) assessed the agreement between the 2 operators. The ascertainment cohort correction factors were applied in a second validation cohort and agreement of the calibrated measures evaluated with repeat Bland-Altman comparisons. Results: A total of 50 infants were enrolled in the initial cohort and 15 in the validation cohort. There was a high degree of correlation between the USCOM operators (ICC = 0.975). USCOM measurements of CO were significantly higher compared to echocardiography (left ventricular output bias 95 +/- 52 mL/kg/min and right ventricular output bias 64 +/- 30 mL/kg/min). There was no difference in the subgroup of infants with and without a ductus arteriosus. After the correction was applied to the validation cohort, there was no longer a significant difference between the measures. Conclusions: CO measured by USCOM consistently overestimated the results obtained from echocardiography. USCOM is not adequate to provide absolute estimates of CO. However, it may allow longitudinal hemodynamic assessment of sick neonates.
引用
收藏
页码:260 / 268
页数:9
相关论文
共 26 条
  • [1] MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES
    ALTMAN, DG
    BLAND, JM
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) : 307 - 317
  • [2] NON-INVASIVE PULSED DOPPLER DETERMINATION OF CARDIAC-OUTPUT IN NEONATES AND CHILDREN
    ALVERSON, DC
    ELDRIDGE, M
    DILLON, T
    YABEK, SM
    BERMAN, W
    [J]. JOURNAL OF PEDIATRICS, 1982, 101 (01) : 46 - 50
  • [3] Incidents and complications during pediatric cardiac catheterization
    Bennett, D
    Marcus, R
    Stokes, M
    [J]. PEDIATRIC ANESTHESIA, 2005, 15 (12) : 1083 - 1088
  • [4] Brierley J, 2006, EUR J PEDIATR S1, V165, P20
  • [5] Perioperative complications in children with pulmonary hypertension undergoing noncardiac surgery or cardiac catheterization
    Carmosino, Mario J.
    Friesen, Robert H.
    Doran, Aimee
    Ivy, Dunbar D.
    [J]. ANESTHESIA AND ANALGESIA, 2007, 104 (03) : 521 - 527
  • [6] Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery
    Chand, Rajesh
    Mehta, Yatin
    Trehan, Naresh
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 20 (03) : 315 - 319
  • [7] A meta-analysis of the accuracy and precision of the ultrasonic cardiac output monitor (USCOM)
    Chong, S. W.
    Peyton, P. J.
    [J]. ANAESTHESIA, 2012, 67 (11) : 1266 - 1271
  • [8] Dey Ian, 2005, Emerg Med Australas, V17, P193
  • [9] Intra- and inter-observer reliability using a noninvasive ultrasound cardiac output monitor in healthy anesthetized children
    Dhanani, Sonny
    Barrowman, Nick J.
    Ward, Roxanne E.
    Murto, Kimmo T.
    [J]. PEDIATRIC ANESTHESIA, 2011, 21 (08) : 858 - 864
  • [10] Which inotrope for which baby?
    Evans, N
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2006, 91 (03): : F213 - F220