Methodical evaluation and improvement of matrix compatible PDMS-overcoated coating for direct immersion solid phase microextraction gas chromatography (DI-SPME-GC)-based applications

被引:42
作者
Souza-Silva, Erica A. [1 ]
Gionfriddo, Emanuela [1 ]
Shirey, Robert [2 ]
Sidisky, Len [2 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, 200 Univ Ave West, Waterloo, ON N2L 3G1, Canada
[2] Supelco Inc, 595 North Harrison Rd, Bellefonte, PA 16823 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Solid-phase microextraction (SPME); Coatings; Gas chromatography (GC); Food analysis; Pesticides residues; Matrix-compatible; TANDEM MASS-SPECTROMETRY; SPME; FOOD; BIOANALYSIS; EXTRACTION; RESIDUES; SORPTION; SAMPLES; FRUITS; FIBER;
D O I
10.1016/j.aca.2016.03.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The main quest for the implementation of direct SPME to complex matrices has been the development of matrix compatible coatings that provide sufficient sensitivity towards the target analytes. In this context, we present here a thorough evaluation of PDMS-overcoated fibers suitable for simultaneous extraction of different polarities analytes, while maintaining adequate matrix compatibility. For this, eleven analytes were selected, from various application classes (pesticides, industrial chemicals and pharmaceuticals) and with a wide range of log P values (ranging from 1.43 to 6). The model matrix chosen was commercial Concord grape juice, which is rich in pigments such as anthocyanins, and contains approximately 20% of sugar (w/w). Two types of PDMS, as well as other intrinsic factors associated with the PDMS-overcoated fiber fabrication are studied. The evaluation showed that the PDMS-overcoated fibers considerably slowed down the coating fouling process during direct immersion in complex matrices of high sugar content. Longevity differences could be seen between the two types of PDMS tested, with a proprietary Sylgard (R) giving superior performance because of lesser amount of reactive groups and enhanced hydrophobicity. Conversely, the thickness of the outer layer did not seem to have a significant effect on the fiber lifetime. We also demonstrate that the uniformity of the overcoated PDMS layer is paramount to the achievement of reliable data and extended fiber lifetime. Employing the optimum overcoated fiber, limits of detection (LOD) in the range of 0.2-1.3 ng/g could be achieved. Additional improvement is attainable by introducing washing of the coatings after desorption, so that any carbon build-up (fouling) left on the coating surface after thermal desorption can be removed. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 62
页数:9
相关论文
共 29 条
[1]   SPME Fibers for the Analysis of Pesticide Residues in Fruits and Vegetables: A Review [J].
Abdulra'uf, Lukman Bola ;
Hammed, Wasiu Adebayo ;
Tan, Guan Huat .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2012, 42 (02) :152-161
[2]   Solid phase microextraction fills the gap in tissue sampling protocols [J].
Bojko, Barbara ;
Gorynski, Krzysztof ;
Gomez-Rios, German Augusto ;
Knaak, Jan Matthias ;
Machuca, Tiago ;
Spetzler, Vinzent Nikolaus ;
Cudjoe, Erasmus ;
Hsin, Michael ;
Cypel, Marcelo ;
Selzner, Markus ;
Liu, Mingyao ;
Keshavjee, Shaf ;
Pawliszyn, Janusz .
ANALYTICA CHIMICA ACTA, 2013, 803 :75-81
[3]   SPME - Quo vadis? [J].
Bojko, Barbara ;
Cudjoe, Erasmus ;
Gomez-Rios, German A. ;
Gorynski, Krzysztof ;
Jiang, Ruifen ;
Reyes-Garces, Nathaly ;
Risticevic, Sanja ;
Silva, Erica A. S. ;
Togunde, Oluranti ;
Vuckovic, Dajana ;
Pawliszyn, Janusz .
ANALYTICA CHIMICA ACTA, 2012, 750 :132-151
[4]   Solid-phase microextraction. How far are we from clinical practice? [J].
Bojko, Barbara ;
Cudjoe, Erasmus ;
Wasowicz, Marcin ;
Pawliszyn, Janusz .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (09) :1505-1512
[5]   Vinyl crown ether as a novel radical crosslinked sol-gel SPME fiber for determination of organophosphorus pesticides in food samples [J].
Cai, LS ;
Gong, SL ;
Chen, M ;
Wu, CY .
ANALYTICA CHIMICA ACTA, 2006, 559 (01) :89-96
[6]  
Cudjoe E, 2012, BIOANALYSIS, V4, P2605, DOI [10.4155/bio.12.250, 10.4155/BIO.12.250]
[7]   Optimization of poly-di-methyl-siloxane (PDMS) substrates for studying cellular adhesion and motility [J].
Fuard, D. ;
Tzvetkova-Chevolleau, T. ;
Decossas, S. ;
Tracqui, P. ;
Schiavone, P. .
MICROELECTRONIC ENGINEERING, 2008, 85 (5-6) :1289-1293
[8]   Headspace versus Direct Immersion Solid Phase Microextraction in Complex Matrixes: Investigation of Analyte Behavior in Multicomponent Mixtures [J].
Gionfriddo, Emanuela ;
Souza-Silva, Erica A. ;
Pawliszyn, Janusz .
ANALYTICAL CHEMISTRY, 2015, 87 (16) :8448-8456
[9]   Thermodynamic Study on Dynamic Water Vapor Sorption in Sylgard-184 [J].
Harley, Stephen J. ;
Glascoe, Elizabeth A. ;
Maxwell, Robert S. .
JOURNAL OF PHYSICAL CHEMISTRY B, 2012, 116 (48) :14183-14190
[10]   Recent analyses using solid phase microextraction in industries related to food made into or from liquids [J].
Heaven, Michael W. ;
Nash, David .
FOOD CONTROL, 2012, 27 (01) :214-227