Comparing the accuracy of open-source pose estimation methods for measuring gait kinematics

被引:28
作者
Washabaugh, Edward P. [1 ,2 ]
Shanmugam, Thanikai Adhithiyan [2 ]
Ranganathan, Rajiv [3 ]
Krishnan, Chandramouli [2 ,4 ,5 ,6 ]
机构
[1] Wayne State Univ, Dept Biomed Engn, Detroit, MI USA
[2] Michigan Med, Dept Phys Med & Rehabil, Ann Arbor, MI USA
[3] Michigan State Univ, Dept Kinesiol, E Lansing, MI USA
[4] Univ Michigan, Michigan Robot Inst, Ann Arbor, MI USA
[5] Univ Michigan Flint, Coll Hlth Sci, Dept Phys Therapy, Flint, MI USA
[6] Univ Michigan, Dept Phys Med & Rehabil, Michigan Med, 325 E Eisenhower Pkwy Suite 3013, Ann Arbor, MI 48108 USA
基金
美国国家科学基金会;
关键词
Low-cost; Angle; Impairment; Training; Rehabilitation; VALIDITY;
D O I
10.1016/j.gaitpost.2022.08.008
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Open-source pose estimation is rapidly reducing the costs associated with motion capture, as ma-chine learning partially eliminates the need for specialized cameras and equipment. This technology could be particularly valuable for clinical gait analysis, which is often performed qualitatively due to the prohibitive cost and setup required for conventional, marker-based motion capture. Research Question: How do open-source pose estimation software packages compare in their ability to measure kinematics and spatiotemporal gait parameters for gait analysis? Methods: This analysis used an existing dataset that contained video and synchronous motion capture data from 32 able-bodied participants while walking. Sagittal plane videos were analyzed using pre-trained algorithms from four open-source pose estimation methods-OpenPose, Tensorflow MoveNet Lightning, Tensorflow MoveNet Thunder, and DeepLabCut-to extract keypoints (i.e., landmarks) and calculate hip and knee kine-matics and spatiotemporal gait parameters. The absolute error when using each markerless pose estimation method was computed against conventional marker-based optical motion capture. Errors were compared be-tween pose estimation methods using statistical parametric mapping. Results: Pose estimation methods differed in their ability to measure kinematics. OpenPose and Tensorflow MoveNet Thunder methods were most accurate for measuring hip kinematics, averaging 3.7 +/- 1.3 deg and 4.6 +/- 1.8 deg (mean & PLUSMN; std) over the entire gait cycle, respectively. OpenPose was most accurate when measuring knee kinematics, averaging 5.1 +/- 2.5 deg of error over the gait cycle. MoveNet Thunder and OpenPose had the lowest errors when measuring spatiotemporal gait parameters but were not statistically different from one another. Significance: The results indicate that OpenPose significantly outperforms other existing platforms for pose -estimation of healthy gait kinematics and spatiotemporal gait parameters and could serve as an alternative to conventional motion capture systems in clinical and research settings when marker-based systems are not available.
引用
收藏
页码:188 / 195
页数:8
相关论文
共 22 条
  • [1] Abadi M., 2016, arXiv
  • [2] [Anonymous], 2011, LANCET, V377, P1977, DOI 10.1016/S0140-6736(11)60844-1
  • [3] Reliability of videotaped observational gait analysis in patients with orthopedic impairments
    Brunnekreef, JJ
    van Uden, CJT
    van Moorsel, S
    Kooloos, JGM
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2005, 6 (1)
  • [4] OpenPose: Realtime Multi-Person 2D Pose Estimation Using Part Affinity Fields
    Cao, Zhe
    Hidalgo, Gines
    Simon, Tomas
    Wei, Shih-En
    Sheikh, Yaser
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2021, 43 (01) : 172 - 186
  • [5] Gait differences between individuals with post-stroke hemiparesis and non-disabled controls at matched speeds
    Chen, G
    Patten, C
    Kothari, DH
    Zajac, FE
    [J]. GAIT & POSTURE, 2005, 22 (01) : 51 - 56
  • [6] Review of low frame rate effects on human performance
    Chen, Jessie Y. C.
    Thropp, Jennifer E.
    [J]. IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART A-SYSTEMS AND HUMANS, 2007, 37 (06): : 1063 - 1076
  • [7] Gait adaptations with aging in healthy participants and people with knee joint osteoarthritis
    Duffell, Lynsey D.
    Jordan, Stevan J.
    Cobb, Justin P.
    McGregor, Alison H.
    [J]. GAIT & POSTURE, 2017, 57 : 246 - 251
  • [8] Movement Patterns of the Knee During Gait Following ACL Reconstruction: A Systematic Review and Meta-Analysis
    Kaur, Mandeep
    Ribeiro, Daniel Cury
    Theis, Jean-Claude
    Webster, Kate E.
    Sole, Gisela
    [J]. SPORTS MEDICINE, 2016, 46 (12) : 1869 - 1895
  • [9] A low cost real-time motion tracking approach using webcam technology
    Krishnan, Chandramouli
    Washabaugh, Edward P.
    Seetharaman, Yogesh
    [J]. JOURNAL OF BIOMECHANICS, 2015, 48 (03) : 544 - 548
  • [10] Calibrated and synchronized multi-view video and motion capture dataset for evaluation of gait recognition
    Kwolek, Bogdan
    Michalczuk, Agnieszka
    Krzeszowski, Tomasz
    Switonski, Adam
    Josinski, Henryk
    Wojciechowski, Konrad
    [J]. MULTIMEDIA TOOLS AND APPLICATIONS, 2019, 78 (22) : 32437 - 32465