The oxygen production pre-combustion (OPPC) IGCC plant for efficient power production with CO2 capture

被引:23
作者
Arnaiz del Pozo, Carlos [2 ]
Cloete, Schalk [1 ]
Cloete, Jan Hendrik [1 ]
Jimenez Alvaro, Angel [2 ]
Amini, Shahriar [1 ]
机构
[1] SINTEF Ind, Trondheim, Norway
[2] Univ Politecn Madrid, Madrid, Spain
关键词
Gas switching oxygen production; CO2; capture; Efficiency; Integrated gasification combined cycle; Pre-combustion; CHEMICAL-LOOPING-COMBUSTION; GASIFICATION COMBINED-CYCLE; AIR SEPARATION; PROCESS SIMULATION; CARBON CAPTURE; HOT GAS; COAL; INTEGRATION; DESIGN; SHIFT;
D O I
10.1016/j.enconman.2019.112109
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work presents a novel integrated gasification combined cycle (IGCC) power plant configuration for CO2 capture with minimal energy penalty. The proposed oxygen production pre-combustion (OPPC) power plant synergistically integrates a gas switching oxygen production (GSOP) unit into a pre-combustion IGCC power plant, reducing the energy penalty through two channels: 1) avoidance of a cryogenic air separation unit and 2) pre-heating the air sent to the combined power cycle, which reduces the steam requirement for shifting CO to H-2 and the CO2 capture duty involved in pre-combustion CO2 capture. Relative to a conventional pre-combustion IGCC benchmark, the OPPC configuration improves the electric efficiency by about 6%-points, although the CO2 capture ratio reduces by about 6%-points. OPPC as avoids the maximum temperature limitation of Chemical Looping Combustion based plants, and can therefore benefit from efficient modern gas turbine technology operating at very high inlet temperatures. CO2 removal via physical absorption (Selexol) generally results in higher efficiencies, but lower CO2 avoidance than chemical absorption (MDEA). Plant efficiency also benefits from an increase in GSOP operating temperature, although the maximum temperature was limited to 900 degrees C to avoid any temperature-related challenges with oxygen carrier stability or downstream valves and filters. OPPC therefore appears to be a promising configuration for minimizing the energy penalty of CO2 capture in IGCC power plants, combining well known and proven technology blocks with a GSOP reactor cluster instead of an ASU.
引用
收藏
页数:20
相关论文
共 55 条
  • [1] Conceptual design of a 100 MWth CLC unit for solid fuel combustion
    Abad, Alberto
    Adanez, Juan
    Gayan, Pilar
    de Diego, Luis F.
    Garcia-Labiano, Francisco
    Sprachmann, Gerald
    [J]. APPLIED ENERGY, 2015, 157 : 462 - 474
  • [2] [Anonymous], J ENERGY RES TECHNOL
  • [3] [Anonymous], SCENARIO ANAL ACCELE
  • [4] [Anonymous], 2015, MITSUBISHI HEAVY IND
  • [5] [Anonymous], ASS REP MIT CLIM CHA
  • [6] [Anonymous], HYDROGEN POWER GENER
  • [7] [Anonymous], GAS TECHN C
  • [8] [Anonymous], 2018, WARM 1 5 C INT PAN C
  • [9] [Anonymous], 2015, PROJ COSTS GEN EL
  • [10] The potential of chemical looping combustion using the gas switching concept to eliminate the energy penalty of CO2 capture
    Arnaiz del Pozo, Carlos
    Cloete, Schalk
    Cloete, Jan Hendrik
    Jimenez Alvaro, Angel
    Amini, Shahriar
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2019, 83 : 265 - 281