Pulmonary Imaging of Immunocompromised Patients during Hematopoietic Stem Cell Transplantation using Non-Contrast-Enhanced Three-Dimensional Ultrashort Echo Time (3D-UTE) MRI

被引:2
|
作者
Metz, Corona [1 ]
Boeckle, David [2 ]
Heidenreich, Julius Frederik [1 ]
Weng, Andreas Max [1 ]
Benkert, Thomas [3 ]
Grigoleit, Gotz Ulrich [2 ]
Bley, Thorsten [1 ]
Koestler, Herbert [1 ]
Veldhoen, Simon [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Wurzburg, Germany
[2] Univ Hosp Wurzburg, Dept Internal Med Hematol & Oncol 2, Wurzburg, Germany
[3] Siemens Healthcare GmbH, Applicat Dev, Erlangen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2022年 / 194卷 / 01期
关键词
thorax; infection; ultrashort echo time; magnetic resonance imaging; pulmonary imaging; hematopoietic stem cell transplantation; COMPUTED-TOMOGRAPHY; NEUTROPENIC PATIENTS; LUNG MRI; PNEUMONIA; COMPLICATIONS; SEQUENCES; STANDARD; DISEASE; NODULES;
D O I
10.1055/a-1535-2341
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the feasibility of non-contrast-enhanced three-dimensional ultrashort echo time (3D-UTE) MRI for pulmonary imaging in immunocompromised patients during hematopoietic stem cell transplantation (HSCT). Methods MRI was performed using a stack-of-spirals 3D-UTE sequence (slice thickness: 2.34mm; matrix: 256 x 256; acquisition time: 12.7-17.6 seconds) enabling imaging of the entire thorax within single breath-holds. Patients underwent MRI before HSCT initiation, in the case of periprocedural pneumonia, before discharge, and in the case of re-hospitalization. Two readers separately assessed the images regarding presence of pleural effusions, ground glass opacities (GGO), and consolidations on a per lung basis. A T2-weighted (T2w) multishot Turbo Spin Echo sequence (BLADE) was acquired in coronal orientation during breath-hold (slice thickness: 6.00mm; matrix: 320 x 320; acquisition time: 3.1-5.5 min) and read on a per lesion basis. Low-dose CT scans in inspiration were used as reference and were read on a per lung basis. Only scans performed within a maximum of three days were included in the inter-method analyses. Interrater agreement, sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of 3D-UTE MRI were calculated. Results 67 MRI scans of 28 patients were acquired. A reference CT examination was available for 33 scans of 23 patients. 3D-UTE MRI showed high sensitivity and specificity regarding pleural effusions (n =6; sensitivity, 92%; specificity, 100%) and consolidations (n =22; sensitivity 98%, specificity, 86%). Diagnostic performance was lower for GGO (n = 9; sensitivity, 63%; specificity, 84%). Accuracy rates were high (pleural effusions, 98%; GGO, 79%; consolidations 94%). Interrater agreement was substantial for consolidations and pleural effusions (kappa=0.69-0.82) and moderate for GGO (kappa=0.54). Compared to T2w imaging, 3D-UTE MRI depicted the assessed pathologies with at least equivalent quality and was rated superior regarding consolidations and GGO in similar to 50%. Conclusion Non-contrast 3D-UTE MRI enables radiation-free assessment of typical pulmonary complications during HSCT procedure within a single breath-hold. Yet, CT was found to be superior regarding the identification of pure GGO changes.
引用
收藏
页码:39 / 48
页数:10
相关论文
共 5 条
  • [1] Evaluation of pulmonary ventilation in COVID-19 patients using oxygen-enhanced three-dimensional ultrashort echo time MRI: a preliminary study
    Zhao, F.
    Zheng, L.
    Shan, F.
    Dai, Y.
    Shen, J.
    Yang, S.
    Shi, Y.
    Xue, K.
    Zhang, Z.
    CLINICAL RADIOLOGY, 2021, 76 (05) : 391.e33 - 391.e41
  • [2] Three-dimensional ultrashort echo time cones (3D UTE-Cones) magnetic resonance imaging of entheses and tendons
    Chen, Bimin
    Zhao, Yinghua
    Cheng, Xin
    Ma, Yajun
    Chang, Eric Y.
    Kavanaugh, Arthur
    Liu, Sirun
    Du, Jiang
    MAGNETIC RESONANCE IMAGING, 2018, 49 : 4 - 9
  • [3] Three-dimensional ultrashort echo time (3D UTE) MRI of Achilles tendon at 4.7T MRI with comparison to conventional sequences in an experimental murine model of spondyloarthropathy
    Dallaudiere, Benjamin
    Trotier, A.
    Ribot, E.
    Verdier, D.
    Lepreux, S.
    Miraux, S.
    Hauger, O.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (01) : 127 - 135
  • [4] Pulmonary ventilation imaging in asthma and cystic fibrosis using oxygen-enhanced 3D radial ultrashort echo time MRI
    Zha, Wei
    Kruger, Stanley J.
    Johnson, Kevin M.
    Cadman, Robert V.
    Bell, Laura C.
    Liu, Fang
    Hahn, Andrew D.
    Evans, Michael D.
    Nagle, Scott K.
    Fain, Sean B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (05) : 1287 - 1297
  • [5] Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method
    Ma, Ya-Jun
    Lu, Xing
    Carl, Michael
    Zhu, Yanchun
    Szeverenyi, Nikolaus M.
    Bydder, Graeme M.
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 598 - 608