Economic advantage of 'self-made' antibiotic-loaded spacer compared to prefabricated antibiotic-loaded spacer and spacer molds in two-staged revision arthroplasty

被引:0
|
作者
Moerenhout, K. [1 ,2 ]
Steinmetz, S. [1 ,2 ]
Vautrin, M. [1 ,2 ]
Picarra, S. [2 ,3 ]
Udin, G. [1 ,2 ]
Borens, O. [1 ,2 ]
机构
[1] Lausanne Univ Hosp, Serv Orthoped & Traumatol, Lausanne, Switzerland
[2] Univ Lausanne, Lausanne, Switzerland
[3] Lausanne Univ Hosp, Dept Interdisciplinary Care, Lausanne, Switzerland
来源
ACTA ORTHOPAEDICA BELGICA | 2021年 / 87卷 / 03期
关键词
economic analysis; spacer; prosthetic joint infection; two-stage exchange; INFECTION;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Infection after total hip or total knee arthroplasty is a serious complication implying great costs for the health care system. Amongst the different treatment options, the two-step exchange using a spacer in the interval is a valid option. We evaluate the economic impact of our self-made antibiotic-loaded hip and knee cement spacers compared with prefabricated spacers and spacer molds. Costs to prepare self-made cement spacers are detailed for each spacer type. We also assess the intraoperative time spent for fabricating our self-made hip and knee spacers. The price of these self-made knee spacer is 514 CHF (450 EUR / 505 USD) if non-articulated and 535 CHF (470 EUR / 525 USD) if articulated; the price for the self-made hip spacer is 749 CHF (760 EUR / 735 USD). Our average preparation time is 14 minutes for our self-made knee spacers and 16 minutes for our self-made hip spacers. While the senior surgeon is fabricating the self-spacers, another surgeon of the team continues intensive irrigation and debridement. Thus, no time is lost waiting for the self-spacer to be fabricated. In our hands, self-made hip and knee spacers are at least 40-50% cheaper than prefabricated spacers and spacer-molds. This is a serious economic advantage in this already expensive surgery. When done in teamwork, self-spacer fabrication does not increase the surgery time. The economic advantage is added to the main and most important advantage of selfmade spacers, which remains the possibility of patient adapted anatomical reconstruction of the joint.
引用
收藏
页码:557 / 562
页数:6
相关论文
共 38 条
  • [1] Two-stage revision hip arthroplasty for infection with a custom-made, antibiotic-loaded, cement prosthesis as an interim spacer
    Hsieh, PH
    Chen, LH
    Chen, CH
    Lee, MS
    Yang, WE
    Shih, CH
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 56 (06): : 1247 - 1252
  • [2] A simple method for construction of an articulating antibiotic-loaded cement spacer
    Shin, SS
    Della Valle, CJ
    Ong, BC
    Meere, PA
    JOURNAL OF ARTHROPLASTY, 2002, 17 (06) : 785 - 787
  • [3] A Customized Knee Antibiotic-Loaded PMMA Spacer: A Preliminary Design Analysis
    Balato, Marco
    Petrarca, Carlo
    Quercia, Antonio
    Riccio, Aniello
    Sellitto, Andrea
    Campi, Jessica
    Borriello, Anna
    Zarrelli, Mauro
    Balato, Giovanni
    POLYMERS, 2021, 13 (23)
  • [4] Management of chronic shoulder infections utilizing a fixed Articulating antibiotic-loaded spacer
    Stine, Ian A.
    Lee, Brian
    Zalavras, Charalampos G.
    Hatch, George, III
    Itamura, John M.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (05) : 739 - 748
  • [5] Intraoperatively-made cement-on-cement antibiotic-loaded articulating spacer for infected total knee arthroplasty
    Shen, Hao
    Zhang, Xianlong
    Jiang, Yao
    Wang, Qiaojie
    Chen, Yunsu
    Wang, Qi
    Shao, Junjie
    KNEE, 2010, 17 (06) : 407 - 411
  • [6] Antibiotic-loaded articulating cement spacer in the 2-stage exchange of infected total knee arthroplasty
    Durbhakula, SM
    Czajka, J
    Fuchs, MD
    Uhl, RL
    JOURNAL OF ARTHROPLASTY, 2004, 19 (06) : 768 - 774
  • [7] Antibiotic-loaded spacer arthroplasty in a terrible triad injury with unreconstructable radial head fracture: a case report
    Barati, Hasan
    Baroutkoub, Mojtaba
    Targhi, Nikaein Zabeti
    Beheshti Fard, Shahabaldin
    Hajikarimloo, Bardia
    Afzal, Sina
    JOURNAL OF MEDICAL CASE REPORTS, 2023, 17 (01)
  • [8] Antibiotic-loaded spacer arthroplasty in a terrible triad injury with unreconstructable radial head fracture: a case report
    Hasan Barati
    Mojtaba Baroutkoub
    Nikaein Zabeti Targhi
    Shahabaldin Beheshti Fard
    Bardia Hajikarimloo
    Sina Afzal
    Journal of Medical Case Reports, 17
  • [9] Prospective study of the treatment of infected hip arthroplasties with or without the use of an antibiotic-loaded cement spacer
    Cabrita, Henrique Berwanger
    Croci, Alberto Tesconi
    de Camargo, Olavo Pires
    Lei Munhoz de Lima, Ana Lucia
    CLINICS, 2007, 62 (02) : 99 - 108
  • [10] Antibiotic-loaded cement articulating Spacer for 2-stage reimplantation in infected total knee arthroplasty - A simple and economic method
    Hsu, Y. C.
    Cheng, H. C.
    Ng, T. P.
    Chiu, K. Y.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (07) : 1060 - 1066