The effect of carrier surface and bulk properties on drug particle detachment from crystalline lactose carrier particles during inhalation, as function of carrier payload and mixing time

被引:61
作者
Dickhoff, BHJ
de Boer, AH
Lambregts, D
Frijlink, HW
机构
[1] Univ Groningen, GUIDE, Dept Pharmaceut Technol & Biopharm, NL-9713 AV Groningen, Netherlands
[2] DMV Int, Veghel, Netherlands
关键词
adhesive mixtures; bulk properties; budesonide; disodium chromoglycate; mixing time; lactose; carrier payload;
D O I
10.1016/S0939-6411(03)00109-7
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The effect of carrier payload and mixing time on the redispersion of drug particles from adhesive mixtures during inhalation for two different drugs (budesonide and disodium cromoglycate) has been investigated. A special test inhaler which retains carrier crystals during inhalation was used at 30 and 60 1/min. The special inhaler enabled the analysis of residual drug on the carrier yielding so called carrier residue (CR) values. Mixtures with carrier size fractions of 32-45; 150-200 and 250-355 mum, derived from marketed lactose brands, with increasing carrier payload (0.4-6.0% w/w of drug) were prepared. It was found that with increasing carrier payload, the CR increases for the coarse carrier fraction, decreases for the fine fraction and remains roughly constant for the intermediate fraction at 301/min. At 601/min, the CR decreased for all carrier fractions with increasing payload. The effect of powder bulk properties on the adhesive forces between drug and carrier (during mixing) as well as changes in the balance between adhesion and separation forces (during inhalation) explain the results found. An improved understanding of the different effects is obtained through the recently introduced force distribution concept. The ratio of (mean) separation force to (mean) adhesion force increases with the flow rate. The adhesive forces (during mixing) increase with increasing carrier diameter (higher press-on and kneading forces) and longer mixing time. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:291 / 302
页数:12
相关论文
共 47 条
[1]  
[Anonymous], ADV PHARM SCI
[2]  
AULTON M, 1996, PHARM AEROSOLS DRY P, P1
[3]   SOME FUTURE PERSPECTIVES FOR UNIT DOSE INHALATION AEROSOLS [J].
BYRON, PR .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1986, 12 (07) :993-1015
[4]   Influence of particle size, air flow, and inhaler device on the dispersion of mannitol powders as aerosols [J].
Chew, NYK ;
Chan, HK .
PHARMACEUTICAL RESEARCH, 1999, 16 (07) :1098-1103
[5]  
COLOMBO P, 2000, RESP DRUG DELIVERY, V7, P629
[6]   Air classifier technology (ACT) in dry powder inhalation - Part I. Introduction of a novel force distribution concept (FDC) explaining the performance of a basic air classifier on adhesive mixtures [J].
de Boer, AH ;
Hagedoorn, P ;
Gjaltema, D ;
Goede, J ;
Frijlink, HW .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2003, 260 (02) :187-200
[7]   Air classifier technology (ACT) in dry powder inhalation Part II. The effect of lactose carrier surface properties on the drug-to-carrier interaction in adhesive mixtures for inhalation [J].
de Boer, AH ;
Hagedoorn, P ;
Gjaltema, D ;
Goede, J ;
Kussendrager, KD ;
Frijlink, HW .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2003, 260 (02) :201-216
[8]  
DEBOER AH, 2002, DRUG DELIVERY LUNGS, V13
[9]   The effect of budesonide particle mass on drug particle detachment from carrier crystals in adhesive mixtures during inhalation [J].
Dickhoff, BHJ ;
Ellison, MJH ;
de Boer, AH ;
Frijlink, HW .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2002, 54 (02) :245-248
[10]  
DICKHOFF BHJ, 2002, DRUG DELIVERY LUNGS, V13