Dynamic cardiac MRI reconstruction using motion aligned locally low rank tensor (MALLRT)

被引:27
|
作者
Liu, Fan [1 ]
Li, Dongxiao [1 ]
Jin, Xinyu [1 ]
Qiu, Wenyuan [1 ]
Xia, Qi [2 ]
Sun, Bin [1 ]
机构
[1] Zhejiang Univ, Coll Informat Sci & Elect Engn, 38 Zheda Rd, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Affiliated Hosp 1, Hangzhou, Peoples R China
关键词
Cardiac dynamic MRI; Compressed sensing; Patch tensor; Locally low rank; Motion alignment; EXPLOITING SPARSITY; REGULARIZATION; DECOMPOSITION; ALGORITHM;
D O I
10.1016/j.mri.2019.07.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Various sparse transform models have been explored for compressed sensing-based dynamic cardiac MRI reconstruction from vastly under-sampled k-space data. Recently emerged low rank tensor model using Tucker decomposition could be viewed as a special form of sparse model, where the core tensor, which is obtained using high-order singular value decomposition, is sparse in the sense that only a few elements have dominantly large magnitude. However, local details tend to be over-smoothed when the entire image is conventionally modeled as a global tensor. Moreover, low rankness is sensitive to motion as spatiotemporal correlation is corrupted by spatial misalignment between temporal frames. To overcome these limitations, this paper presents a novel motion aligned locally low rank tensor (MALLRT) model for dynamic MRI reconstruction. In MALLRT, low rank constraint is enforced on image patch-based local tensors, which correspond to overlapping blocks extracted from the reconstructed high-dimensional image after group-wise inter-frame motion registration. For solving the proposed model, this paper presents an efficient optimization algorithm by using variable splitting and alternating direction method of multipliers (ADMM). MALLRT demonstrated promising performance as validated on one cardiac perfusion MRI dataset and two cardiac tine MRI datasets using retrospective under-sampling with various acceleration factors, as well as one prospectively under-sampled cardiac perfusion MRI dataset. Compared to four state-of-the-art methods, MALLRT achieved substantially better image reconstruction quality in terms of both signal to error ratio (SER) and structural similarity index (SSIM) metrics, and visual perception in preserving spatial details and capturing temporal variations.
引用
收藏
页码:104 / 115
页数:12
相关论文
共 50 条
  • [41] Improved Dynamic Contrast-Enhanced MRI Using Low Rank With Joint Sparsity
    Zhang, Jichang
    Najeeb, Faisal
    Wang, Xinpei
    Xu, Pengfei
    Omer, Hammad
    Zheng, Jianjun
    Zhang, Jingfeng
    Francis, Sue
    Glover, Paul
    Bowtell, Richard
    Wang, Chengbo
    IEEE ACCESS, 2022, 10 : 121193 - 121203
  • [42] Reconstruction of Cardiac Perfusion MRI with Motion Compensated Compressed Sensing
    Tolouee, Azar
    Alirezaie, Javad
    Babyn, Paul
    2020 IEEE 5TH MIDDLE EAST AND AFRICA CONFERENCE ON BIOMEDICAL ENGINEERING (MECBME), 2020, : 24 - 28
  • [43] Motion-Compensated Compressed Sensing for Dynamic Contrast-Enhanced MRI Using Regional Spatiotemporal Sparsity and Region Tracking: Block LOw-rank Sparsity with Motion-guidance (BLOSM)
    Chen, Xiao
    Salerno, Michael
    Yang, Yang
    Epstein, Frederick H.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) : 1028 - 1038
  • [44] Improving synthesis and analysis prior blind compressed sensing with low-rank constraints for dynamic MRI reconstruction
    Majumdar, Angshul
    MAGNETIC RESONANCE IMAGING, 2015, 33 (01) : 174 - 179
  • [45] Sparsity regularized nonlinear inverse reconstruction for subsampled Parallel Dynamic Cardiac MRI
    Pu, Haowen
    Jia, Sen
    Yang, Ran
    2014 19TH INTERNATIONAL CONFERENCE ON DIGITAL SIGNAL PROCESSING (DSP), 2014, : 801 - 806
  • [46] A Kernel-Based Low-Rank (KLR) Model for Low-Dimensional Manifold Recovery in Highly Accelerated Dynamic MRI
    Nakarmi, Ukash
    Wang, Yanhua
    Lyu, Jingyuan
    Liang, Dong
    Ying, Leslie
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (11) : 2297 - 2307
  • [47] Accelerating PS model-based dynamic cardiac MRI using compressed sensing
    Zhang, Xiaoyong
    Xie, Guoxi
    Shi, Caiyun
    Su, Shi
    Zhang, Yongqin
    Liu, Xin
    Qiu, Bensheng
    MAGNETIC RESONANCE IMAGING, 2016, 34 (02) : 81 - 90
  • [48] Cardiac diffusion tensor imaging based on compressed sensing using joint sparsity and low-rank approximation
    Huang, Jianping
    Wang, Lihui
    Chu, Chunyu
    Zhang, Yanli
    Liu, Wanyu
    Zhu, Yuemin
    TECHNOLOGY AND HEALTH CARE, 2016, 24 : S593 - S599
  • [49] LOW RANK MATRIX RECOVERY FOR REAL-TIME CARDIAC MRI
    Zhao, Bo
    Haldar, Justin P.
    Brinegar, Cornelius
    Liang, Zhi-Pei
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 996 - 999
  • [50] Hyperspectral image reconstruction based on low-rank coefficient tensor and global prior
    Wan, Xinwei
    Li, Dan
    Lv, Yanyan
    Kong, Fanqiang
    Wang, Qiang
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2023, 44 (13) : 4058 - 4085