Dynamic cardiac MRI reconstruction using motion aligned locally low rank tensor (MALLRT)

被引:27
|
作者
Liu, Fan [1 ]
Li, Dongxiao [1 ]
Jin, Xinyu [1 ]
Qiu, Wenyuan [1 ]
Xia, Qi [2 ]
Sun, Bin [1 ]
机构
[1] Zhejiang Univ, Coll Informat Sci & Elect Engn, 38 Zheda Rd, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Affiliated Hosp 1, Hangzhou, Peoples R China
关键词
Cardiac dynamic MRI; Compressed sensing; Patch tensor; Locally low rank; Motion alignment; EXPLOITING SPARSITY; REGULARIZATION; DECOMPOSITION; ALGORITHM;
D O I
10.1016/j.mri.2019.07.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Various sparse transform models have been explored for compressed sensing-based dynamic cardiac MRI reconstruction from vastly under-sampled k-space data. Recently emerged low rank tensor model using Tucker decomposition could be viewed as a special form of sparse model, where the core tensor, which is obtained using high-order singular value decomposition, is sparse in the sense that only a few elements have dominantly large magnitude. However, local details tend to be over-smoothed when the entire image is conventionally modeled as a global tensor. Moreover, low rankness is sensitive to motion as spatiotemporal correlation is corrupted by spatial misalignment between temporal frames. To overcome these limitations, this paper presents a novel motion aligned locally low rank tensor (MALLRT) model for dynamic MRI reconstruction. In MALLRT, low rank constraint is enforced on image patch-based local tensors, which correspond to overlapping blocks extracted from the reconstructed high-dimensional image after group-wise inter-frame motion registration. For solving the proposed model, this paper presents an efficient optimization algorithm by using variable splitting and alternating direction method of multipliers (ADMM). MALLRT demonstrated promising performance as validated on one cardiac perfusion MRI dataset and two cardiac tine MRI datasets using retrospective under-sampling with various acceleration factors, as well as one prospectively under-sampled cardiac perfusion MRI dataset. Compared to four state-of-the-art methods, MALLRT achieved substantially better image reconstruction quality in terms of both signal to error ratio (SER) and structural similarity index (SSIM) metrics, and visual perception in preserving spatial details and capturing temporal variations.
引用
收藏
页码:104 / 115
页数:12
相关论文
共 50 条
  • [11] Acceleration of Perfusion MRI Using Locally Low-Rank Plus Sparse Model
    Dankova, Marie
    Rajmic, Pavel
    Jirik, Radovan
    LATENT VARIABLE ANALYSIS AND SIGNAL SEPARATION, LVA/ICA 2015, 2015, 9237 : 514 - 521
  • [12] Learning the Sparsity Basis in Low-rank plus Sparse Model for Dynamic MRI Reconstruction
    Majumdar, Angshul
    Ward, Rabab K.
    2015 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING (ICASSP), 2015, : 778 - 782
  • [13] Nonrigid motion compensation in compressed sensing reconstruction of cardiac cine MRI
    Tolouee, Azar
    Alirezaie, Javad
    Babyn, Paul
    MAGNETIC RESONANCE IMAGING, 2018, 46 : 114 - 120
  • [14] Motion compensation combining with local low rank regularization for low dose dynamic CT myocardial perfusion reconstruction
    Liu, Jia
    Jin, Shuang
    Li, Qian
    Zhang, Kunpeng
    Yu, Jiahong
    Mo, Ying
    Bian, Zhaoying
    Gao, Yang
    Zhang, Hua
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (14)
  • [15] Improved Motion Correction in Dynamic Contrast-Enhanced MRI Using Low Rank With Soft Weighting
    Zhang, Jichang
    Najeeb, Faisal
    Wang, Yulin
    Wang, Xinpei
    Xu, Pengfei
    Omer, Hammad
    Zheng, Jianjun
    Zhang, Jingfeng
    Francis, Sue
    Glover, Paul
    Bowtell, Richard
    Meersmann, Thomas
    Wang, Chengbo
    IEEE ACCESS, 2025, 13 : 1867 - 1881
  • [16] Low-Rank and Sparse Decomposition Model for Accelerating Dynamic MRI Reconstruction
    Chen, Junbo
    Liu, Shouyin
    Huang, Min
    JOURNAL OF HEALTHCARE ENGINEERING, 2017, 2017
  • [17] Accelerating multi-echo water-fat MRI with a joint locally low-rank and spatial sparsity-promoting reconstruction
    Lugauer, Felix
    Nickel, Dominik
    Wetzl, Jens
    Kiefer, Berthold
    Hornegger, Joachim
    Maier, Andreas
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (02) : 189 - 202
  • [18] A motion assessment method for reference stack selection in fetal brain MRI reconstruction based on tensor rank approximation
    Xu, Haoan
    Shi, Wen
    Sun, Jiwei
    Zheng, Tianshu
    Xu, Xinyi
    Sun, Cong
    Yi, Sun
    Wang, Guangbin
    Wu, Dan
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [19] Motion Adaptive Patch-Based Low-Rank Approach for Compressed Sensing Cardiac Cine MRI
    Yoon, Huisu
    Kim, Kyung Sang
    Kim, Daniel
    Bresler, Yoram
    Ye, Jong Chul
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (11) : 2069 - 2085
  • [20] Deep Network Cascade for Dynamic Cardiac MRI Reconstruction With Motion Feature Incorporation and the Fourier Neural Attention
    Liu, Jingshuai
    Qin, Chen
    Yaghoobi, Mehrdad
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2024, 10 : 774 - 789