Greenhouse gas emission and exergy assessments of an integrated organic Rankine cycle with a biomass combustor for combined cooling, heating and power production

被引:98
作者
Al-Sulaiman, Fahad A. [1 ]
Hamdullahpur, Feridun [1 ]
Dincer, Ibrahim [2 ]
机构
[1] Univ Waterloo, Mech & Mechatron Engn Dept, Waterloo, ON N2L 3G1, Canada
[2] Univ Ontario, Inst Technol, Fac Engn & Appl Sci, Oshawa, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Trigeneration; Organic rankine cycle; Biomass; Exergy efficiency; Exergy destruction; Greenhouse gas emission; FLUID SELECTION; GASIFICATION; ORC;
D O I
10.1016/j.applthermaleng.2010.09.019
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, greenhouse gas emission and exergy assessments of an integrated organic Rankine cycle (ORC) with a biomass combustor for combined cooling, heating, and power production as a trigeneration system are conducted. This trigeneration system consists of a biomass combustor, an ORC, a single-effect absorption chiller, and a heat exchanger. Four special cases are considered in this comprehensive study, namely, electrical power, cooling-cogeneration, heating-cogeneration, and trigeneration cases. Various exergetic and environmental output performance parameters, namely, exergy efficiency, exergy destruction rate, and greenhouse gas emissions, are examined under varying ORC evaporator pinch point temperature, pump inlet temperature, and turbine inlet pressure. This study shows that using trigeneration considerably increases both energy and exergy efficiencies and decreases the greenhouse gas emissions as compared to the electrical power case. This study reveals that the heating-cogeneration and trigeneration cases are less sensitive to the considered temperature and pressure variations as compared with the electrical power and cooling-cogeneration cases. In addition, the results show that when the trigeneration case is used, the exergy efficiency increases significantly to 27% as compared with the exergy efficiency of the electrical power case, which is around 11%. It is also found that the main two sources of exergy destruction are the biomass combustor and ORC evaporator. Moreover, this study shows that the emissions of CO(2) in kg/MWh are significantly high for the electrical power case while for the trigeneration case, the emissions per MWh of trigeneration drop significantly to relatively low level. Specifically, the emissions drop to around one seventh per MWh produced when trigeneration is used as compared with only electrical power production case. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:439 / 446
页数:8
相关论文
共 18 条
  • [1] Trigeneration: A comprehensive review based on prime movers
    Al-Sulaiman, Fahad A.
    Hamdullahpur, Feridun
    Dincer, Ibrahim
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2011, 35 (03) : 233 - 258
  • [2] Energy analysis of a trigeneration plant based on solid oxide fuel cell and organic Rankine cycle
    Al-Sulaiman, Fahad A.
    Dincer, Ibrahim
    Hamdullahpur, Feridun
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (10) : 5104 - 5113
  • [3] Exergy analysis of an integrated solid oxide fuel cell and organic Rankine cycle for cooling, heating and power production
    Al-Sulaiman, Fahad A.
    Dincer, Ibrahim
    Hamdullahpur, Feridun
    [J]. JOURNAL OF POWER SOURCES, 2010, 195 (08) : 2346 - 2354
  • [4] [Anonymous], ASHRAE T
  • [5] [Anonymous], 2008, COMBINED HEAT POWER
  • [6] Alternative ORC bottoming cycles FOR combined cycle power plants
    Chacartegui, R.
    Sanchez, D.
    Munoz, J. M.
    Sanchez, T.
    [J]. APPLIED ENERGY, 2009, 86 (10) : 2162 - 2170
  • [7] Fluid selection for the Organic Rankine Cycle (ORC) in biomass power and heat plants
    Drescher, Ulli
    Brueggemann, Dieter
    [J]. APPLIED THERMAL ENGINEERING, 2007, 27 (01) : 223 - 228
  • [8] Herold K.E., 1996, Absorption Chillers and Heat Pumps
  • [9] Waste heat recovery of organic Rankine cycle using dry fluids
    Hung, TC
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (05) : 539 - 553
  • [10] Kerr T., 2008, COMBINED HEATING POW