Strain gradient effects on flexural strength design of normal-strength concrete columns

被引:12
作者
Ho, J. C. M. [1 ]
Peng, J. [1 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Columns; Concrete stress block; Design; Flexural strength; Normal-strength concrete; Reinforced concrete; Strain gradient; STRESS BLOCK; CONFINED CONCRETE; BEHAVIOR; LOAD; DEFORMABILITY; CAPACITY; TESTS;
D O I
10.1016/j.engstruct.2010.09.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The equivalent rectangular concrete stress block has commonly been adopted for the flexural strength design of reinforced concrete (RC) members for decades. In this stress block, the equivalent concrete stress is expressed as alpha f(c)'(f(c)' is the uni-axial concrete cylinder strength). Currently, the value of a adopted in various RC design codes is only concrete-strength dependent and equal to 0.85 for NSC. However, in an experimental study conducted previously by the authors on NSC columns subjected to concentric and eccentric axial loads, it was found that a increases significantly as the strain gradient increases. Therefore, the effect of the strain gradient should not be neglected. In this paper, a review on the previous test results on NSC columns is presented and a strain-gradient dependent equivalent rectangular concrete stress block is developed. Based on this proposed stress block, a new flexural strength design method for NSC columns that incorporates the effects of the strain gradient is proposed. A series of column interaction diagrams with various concrete strengths and steel ratios are derived for design purposes. Lastly, these interaction diagrams are compared with the existing column design charts provided in various RC design codes to verify their applicability. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:18 / 31
页数:14
相关论文
共 57 条
[41]  
SHEIKH SA, 1993, ACI STRUCT J, V90, P414
[42]   TIED CONCRETE COLUMNS UNDER AXIAL LOAD AND FLEXURE [J].
SHEIKH, SA ;
YEH, CC .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1990, 116 (10) :2780-2800
[43]  
SHEIKH SA, 1994, ACI STRUCT J, V91, P100
[44]   Design of FRP confinement for square concrete columns [J].
Sheikh, Shamim A. ;
Li, Yimin .
ENGINEERING STRUCTURES, 2007, 29 (06) :1074-1083
[45]  
*STAND NZ, 2006, 3101 NZS
[46]  
Standards Australia, 2001, AS36002001 STAND AUS
[47]  
Sturman GM., 1965, ACI J P, V62, P805, DOI 10.14359/7725
[48]   Simulation-based robust design of mass dampers for response mitigation of tension leg platforms [J].
Taflanidis, Alexandros A. ;
Angefides, Demos C. ;
Scruggs, Jeffrey T. .
ENGINEERING STRUCTURES, 2009, 31 (04) :847-857
[49]  
Tan TH, 2005, ACI STRUCT J, V102, P198
[50]   Determination of stress-strain curves of concrete from flexure tests [J].
Tan, TH ;
Nguyen, NB .
MAGAZINE OF CONCRETE RESEARCH, 2004, 56 (04) :243-250