11C-methionine PET/CT after inconclusive 99mTc-MIBI-SPECT/CT for localisation of parathyroid adenomas in primary hyperparathyroidism

被引:18
作者
Braeuning, U. [1 ]
Pfannenberg, C. [2 ]
Gallwitz, B. [3 ]
Teichmann, R. [4 ]
Mueller, M. [1 ]
Dittmann, H. [1 ]
Reimold, M. [1 ]
Bares, R. [1 ]
机构
[1] Univ Hosp Tuebingen, Dept Nucl Med, D-72076 Tubingen, Germany
[2] Univ Hosp Tuebingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[3] Univ Hosp Tuebingen, Dept Internal Med, D-72076 Tubingen, Germany
[4] Univ Hosp Tuebingen, Dept Surg, D-72076 Tubingen, Germany
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 2015年 / 54卷 / 01期
关键词
C-11-methionine-PET/CT; Tc-99m-MIBI-SPECT/CT; primary hyperparathyreoidism; PREOPERATIVE LOCALIZATION; C-11; METHIONINE;
D O I
10.3413/Nukmed-0686-14-07
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: To investigate the efficacy of PET/CT with C-11-methionine for localizing parathyroid adenomas in patients with suspected primary hyperparathyroidism and inconclusive results of cervical ultrasonography and Tc-99m-MIBI-SPECT/CT. Patients, method: Retrospective analysis of imaging data of 18 patients and correlation with clinical outcome, in particular intraoperative findings and histopathology of excised tissue. Results: 12 of 18 patients received surgery. In 10 patients single parathyroid adenomas were found (diameter: 5-20 mm), 2 patients presented parathyroid hyperplasia (5 excised hyperplastic glands (diameter: 2-12 mm). PET/CT correctly localized all adenomas and 1 of 5 hyperplastic glands. The sensitivity per patient was 91.7% (11 of 12), the sensitivity per lesion 73.3% (11 of 15). All lesions missed by; PET/CT had a size smaller than 9 mm and a volume of less than 0.2 ml. In 6 patients no surgery was performed. Five of them had a negative or atypical PET/CT. Further follow-up indicated familial hypocalciuric hypercalcemia in 3 of them (thus, PET/CT true negative), in the remaining 2 patients no validation is available. One patient with 2 highly suggestive lesions rejected surgery so far. Conclusion: PET/CT with C-11-methionine is a very sensitive method for the detection of parathyroid adenomas, even if they are too small to be visualized by Tc-99m-MIBI-SPECT/CT.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 12 条
  • [11] Sundin A, 1996, J NUCL MED, V37, P1766
  • [12] Accurate Preoperative Localization of Parathyroid Adenomas With C-11 Methionine PET/CT
    Weber, Theresia
    Maier-Funk, Clemens
    Ohlhauser, Dagmar
    Hillenbrand, Andreas
    Cammerer, Gregor
    Barth, Thomas F.
    Henne-Bruns, Doris
    Boehm, Bernhard O.
    Reske, Sven N.
    Luster, Markus
    [J]. ANNALS OF SURGERY, 2013, 257 (06) : 1124 - 1128