Surgical site infection after total en bloc spondylectomy: risk factors and the preventive new technology

被引:30
作者
Hayashi, Hiroyuki [1 ]
Murakami, Hideki [1 ]
Demura, Satoru [1 ]
Kato, Satoshi [1 ]
Yoshioka, Katsuhito [1 ]
Shinmura, Kazuya [1 ]
Yokogawa, Noriaki [1 ]
Ishii, Takayoshi [1 ]
Fang, Xiang [1 ]
Shirai, Toshiharu [1 ]
Tsuchiya, Hiroyuki [1 ]
机构
[1] Kanazawa Univ, Grad Sch Med Sci, Dept Orthoped Surg, Kanazawa, Ishikawa 9208641, Japan
关键词
Surgical site infection; Total en bloc spondylectomy; Iodine-supported spinal instrument; Risk factor; Vertebral tumor; Multivariate analysis; TUMORS CLINICAL ARTICLE; SPINAL TUMORS; METASTASES; TITANIUM; SURGERY; POSTERIOR; ANTERIOR;
D O I
10.1016/j.spinee.2014.08.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Surgical site infection (SSI) associated with instruments remains a serious and common complication in patients who undergo total en bloc spondylectomy (TES). It is very important that the risk factors for SSI are known to prevent it. PURPOSE: The purpose of the study was to identify independent risk factors for SSI after TES and evaluate the positive effect of iodine-supported spinal instruments in the prevention of SSI after TES. STUDY DESIGN: This is a retrospective clinical study. PATIENT SAMPLE: One hundred twenty-five patients who underwent TES for vertebral tumor were evaluated. OUTCOME MEASURES: Incidence rate of SSI, risk factors for SSI after TES, and safety of iodine-supported spinal instruments were the outcome measures. METHODS: Risk factors for SSI were analyzed using logistic regression. In recent 69 patients with iodine-supported spinal instruments, the thyroid hormone levels in the blood were examined to confirm if iodine from the implant influenced thyroid function. Postoperative radiological evaluations were performed regularly. RESULTS: The rate of SSI was 6.4% (8/125 patients). By multivariate logistic regression, combined anterior and posterior approach and nonuse of iodine-supported spinal instruments were associated with an increased risk of SSI. The rate of SSI without iodine-supported spinal instruments was 12.5%, whereas the rate with iodine-supported spinal instruments was 1.4%. This difference was statistically significant. There were no detected abnormalities of thyroid gland function with the use of iodine-supported instruments. Among the 69 patients with iodine-supported spinal instruments, 2 patients required additional surgery because of instrument failure. However, there were no obvious involvements with the use of iodine-supported spinal instruments. CONCLUSIONS: This study identified combined anterior and posterior approach and nonuse of iodine-supported spinal instruments to be independent risk factors for SSI after TES. Iodine-supported spinal instrument was extremely effective for prevention of SSI in patients with compromised status, and it had no detection of cytotoxic or adverse effects on the patients. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:132 / 137
页数:6
相关论文
共 21 条
[1]   Two-stage, combined, three-level en bloc spondylectomy for a recurrent post-radiation sarcoma of the lumbar spine [J].
Casadei R. ;
Mavrogenis A.F. ;
De Paolis M. ;
Ruggieri P. .
European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (Suppl 1) :S93-S100
[2]   Surgical Site Infection in Spinal Metastasis Risk Factors and Countermeasures [J].
Demura, Satoru ;
Kawahara, Norio ;
Murakami, Hideki ;
Nambu, Koshi ;
Kato, Satoshi ;
Yoshioka, Katsuhito ;
Okayama, Tadaki ;
Tomita, Katsuro .
SPINE, 2009, 34 (06) :635-639
[3]   Antimicrobial titanium/silver PVD coatings on titanium [J].
Ewald, Andrea ;
Glueckermann, Susanne K. ;
Thull, Roger ;
Gbureck, Uwe .
BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
[4]   A population-based study of surgery for spinal metastases [J].
Finkelstein, JA ;
Zaveri, G ;
Wai, E ;
Vidmar, M ;
Kreder, H ;
Chow, E .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (07) :1045-1050
[5]   Silver-coated megaendoprostheses in a rabbit model - an analysis of the infection rate and toxicological side effects [J].
Gosheger, G ;
Hardes, J ;
Ahrens, H ;
Streitburger, A ;
Buerger, H ;
Erren, M ;
Gunsel, A ;
Kemper, FH ;
Winkelmann, W ;
von Eiff, C .
BIOMATERIALS, 2004, 25 (24) :5547-5556
[6]   Bacteria and cell cytocompatibility studies on coated medical grade titanium surfaces [J].
Harris, L. G. ;
Mead, L. ;
Mueller-Oberlaender, E. ;
Richards, R. G. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2006, 78A (01) :50-58
[7]   Survival, complications and outcome in 282 patients operated for neurological deficit due to thoracic or lumbar spinal metastases [J].
Jansson, KÅ ;
Bauer, HCF .
EUROPEAN SPINE JOURNAL, 2006, 15 (02) :196-202
[8]   Total En Bloc Spondylectomy of the Lower Lumbar Spine A Surgical Techniques of Combined Posterior-Anterior Approach [J].
Kawahara, Norio ;
Tomita, Katsuro ;
Murakami, Hideki ;
Demura, Satoru ;
Yoshioka, Katsuhito ;
Kato, Satoshi .
SPINE, 2011, 36 (01) :74-82
[9]   Total En Bloc Spondylectomy for Spinal Tumors: Surgical Techniques and Related Basic Background [J].
Kawahara, Norio ;
Tomita, Katsuro ;
Murakami, Hideki ;
Demura, Satoru .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2009, 40 (01) :47-+
[10]  
Masse A, 2000, J BIOMED MATER RES, V53, P600, DOI 10.1002/1097-4636(200009)53:5<600::AID-JBM21>3.0.CO