A reagentless and reusable electrochemical aptamer-based sensor for rapid detection of Cd(II)

被引:74
作者
Zhad, Hamid R. Lotfi Zadeh [1 ]
Torres, Yamil M. Rodriguez [1 ,2 ]
Lai, Rebecca Y. [1 ]
机构
[1] Univ Nebraska Lincoln, Dept Chem, Lincoln, NE 68588 USA
[2] Univ Puerto Rico Mayaguez, Ind Biotechnol Program, PR 108, Mayaguez, PR 00682 USA
基金
美国国家科学基金会;
关键词
Electrochemical aptamer-based sensors; Alternating current voltammetry; Cyclic voltammetry; Methylene blue; Cadmium; DNA aptamer; CADMIUM IONS; GOLD NANOPARTICLES; CARBON ELECTRODE; METHYLENE-BLUE; REDOX KINETICS; DNA DUPLEXES; SQUARE-WAVE; PROBE; VOLTAMMETRY; MONOLAYERS;
D O I
10.1016/j.jelechem.2017.09.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the design and fabrication of a "signal-on" electrochemical aptamer-based sensor for detection of cadmium (Cd(II)). A 36-base thiolated and methylene blue (MB)-modified aptamer was used in the fabrication of the sensor. In the absence of Cd(II), the surface-immobilized aptamer probe is presumed to be partially folded. Upon binding to Cd(II), the aptamer probe changes its confirmation and flexibility, which alters the electron transfer kinetics between the tethered MB label and the underlying electrode, resulting in an increase in the MB signal. Parameters affecting the detection of Cd(II) were systematically optimized and the electrochemical performance of the sensor was assessed using both alternating current voltammetry and cyclic voltammetry. The sensor has demonstrated good selectivity and can be employed directly in complex samples such as 50% saliva. Furthermore, it has a fast-response time; the analysis can be completed in similar to 1 min. Similar to other folding- and dynamics-based electrochemical biosensors, it is also regenerable and reusable. With further optimization, it could find applications in the analysis of Cd(II) in biological and environmental samples.
引用
收藏
页码:89 / 94
页数:6
相关论文
共 43 条
  • [1] An environmentally-friendly, highly efficient, gas pressure-assisted sample introduction system for ICP-MS and its application to detection of cadmium and lead in human plasma
    Cao, Yupin
    Deng, Biyang
    Yan, Lizhen
    Huang, Hongli
    [J]. TALANTA, 2017, 167 : 520 - 525
  • [2] On-line preconcentration/determination of cadmium in drinking water on activated carbon using 8-hydroxyquinoline in a flow injection system coupled to an inductively coupled plasma optical emission spectrometer
    Cerutti, S
    Silva, MF
    Gásquez, JA
    Olsina, RA
    Martinez, LD
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (01) : 43 - 50
  • [3] A new way of using ac voltammetry to study redox kinetics in electroactive monolayers
    Creager, SE
    Wooster, TT
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (20) : 4257 - 4263
  • [4] Aptamer and Its Potential Applications for Food Safety
    Dong, Yiyang
    Xu, Yan
    Yong, Wei
    Chu, Xiaogang
    Wang, Daning
    [J]. CRITICAL REVIEWS IN FOOD SCIENCE AND NUTRITION, 2014, 54 (12) : 1548 - 1561
  • [5] EPA
  • [6] (United States Environmental Protection Agency), 2016, NAT PRIM DRINK WAT R
  • [7] TOXIC EFFECTS OF CADMIUM - REVIEW
    FLICK, DF
    KRAYBILL, HF
    DIMITROFF, JM
    [J]. ENVIRONMENTAL RESEARCH, 1971, 4 (02) : 71 - +
  • [8] Development of an electrochemical insulin sensor based on the insulin-linked polymorphic region
    Gerasimov, Jennifer Y.
    Schaefer, Cody S.
    Yang, Weiwei
    Grout, Rebecca L.
    Lai, Rebecca Y.
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 42 : 62 - 68
  • [9] Design and characterization of an electrochemical peptide-based sensor fabricated via "click" chemistry
    Gerasimov, Jennifer Y.
    Lai, Rebecca Y.
    [J]. CHEMICAL COMMUNICATIONS, 2011, 47 (30) : 8688 - 8690
  • [10] Novel imprinted polymeric nanoparticles prepared by sol-gel technique for electrochemical detection of toxic cadmium(II) ions
    Ghanei-Motlagh, M.
    Taher, M. A.
    [J]. CHEMICAL ENGINEERING JOURNAL, 2017, 327 : 135 - 141