Wearable technology in orthopedic trauma surgery-An AO trauma survey and review of current and future applications

被引:11
作者
Braun, Benedikt J. [1 ]
Grimm, Bernd [2 ]
Hanflik, Andrew M. [3 ]
Richter, Peter H. [4 ]
Sivananthan, Sureshan [5 ]
Yarboro, Seth Robert [6 ]
Marmor, Meir T. [7 ]
机构
[1] Eberhard Karls Univ Tuebingen, Univ Hosp Tuebingen, BG Hosp, Schnarrenbergstr 95, D-72076 Tubingen, Germany
[2] Inst Hlth, Human Mot Orthopaed Sports Med & Digital Methods G, Transversal Act, Luxembourg, Luxembourg
[3] Kaiser Permanente Downey, Downey Med Ctr, Dept Orthopaed Surg, Southern Calif Permanente Med Grp, Downey, CA USA
[4] Univ Ulm, Dept Orthopaed Surg, Ulm, Germany
[5] ALT Y Orthopaed Hosp, Kuala Lumpur, Malaysia
[6] Univ Virginia, Charlottesville, VA USA
[7] Univ Calif San Francisco, San Francisco Gen Hosp, Orthopaed Trauma Inst OTI, San Francisco, CA USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2022年 / 53卷 / 06期
关键词
Survey; Wearable activity monitors; AO Trauma; PHYSICAL-ACTIVITY; ACCELEROMETRY; FRACTURES;
D O I
10.1016/j.injury.2022.03.026
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The use of wearable sensors to track activity is increasing. Therefore, a survey among AO Trauma members was conducted to provide an overview of their current utilization and determine future needs and directions. A cross sectional expert opinion survey was administered to members of AO Trauma. Respondents were surveyed concerning their experience, subspeciality, current use characteristics, as well as future needs concerning wearable technology. Three hundred and thirty-three survey sets were available for analysis (Response Rate 16.2%). 20.7% of respondents already use wearable technology as part of their clinical treatment. The most prevalent technology was accelerometry combined with smartphones (75.4%) to measure general patient activity. To facilitate the use of wearable technology in the future, the most pressing issues were cost, patient compliance and validity of results. Wearable activity monitors are currently being used in trauma surgery. Surgeons employing these technologies mostly measure simple activity or activity associated parameters. Cost was the greatest perceived barrier to implementation. Further research, especially concerning the interpretation of the outcome values obtained, is required to facilitate wearable activity monitoring as an objective patient outcome measurement tool. (c) 2022 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )
引用
收藏
页码:1961 / 1965
页数:5
相关论文
共 53 条
  • [1] Biomechanical methods for the assessment of fracture repair
    Augat, P.
    Faschingbauer, M.
    Seide, K.
    Tobita, K.
    Callary, S. A.
    Solomon, L. B.
    Holstein, J. H.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 : S32 - S38
  • [2] Bassett D R., 2019, Kinesiology Review, V8, P11, DOI [DOI 10.1123/KR.2018-0060, 10.1123/kr.2018-0060]
  • [3] Automating sleep stage classification using wireless, wearable sensors
    Boe, Alexander J.
    Koch, Lori L. McGee
    O'Brien, Megan K.
    Shawen, Nicholas
    Rogers, John A.
    Lieber, Richard L.
    Reid, Kathryn J.
    Zee, Phyllis C.
    Jayaraman, Arun
    [J]. NPJ DIGITAL MEDICINE, 2019, 2 (01)
  • [4] Measuring and Influencing Physical Activity with Smartphone Technology: A Systematic Review
    Bort-Roig, Judit
    Gilson, Nicholas D.
    Puig-Ribera, Anna
    Contreras, Ruth S.
    Trost, Stewart G.
    [J]. SPORTS MEDICINE, 2014, 44 (05) : 671 - 686
  • [5] Finding NEEMO: towards organizing smart digital solutions in orthopaedic trauma surgery
    Braun, Benedikt J.
    Grimm, Bernd
    Hanflik, Andrew M.
    Marmor, Meir T.
    Richter, Peter H.
    Sands, Andrew K.
    Sivananthan, Sureshan
    [J]. EFORT OPEN REVIEWS, 2020, 5 (07) : 408 - 420
  • [6] An individualized simulation model based on continuous, independent, ground force measurements after intramedullary stabilization of a tibia fracture
    Braun, Benedikt J.
    Pohlemann, Tim
    Herath, Steven C.
    Klein, Moritz
    Rollmann, Mika F.
    Derr, Ralf
    Diebels, Stefan
    Roland, Michael
    [J]. ARCHIVE OF APPLIED MECHANICS, 2019, 89 (11) : 2351 - 2360
  • [7] Increased therapy demand and impending loss of previous residence status after proximal femur fractures can be determined by continuous gait analysis - A clinical feasibility study
    Braun, Benedikt J.
    Osche, David
    Rollmann, Mika
    Orth, Marcel
    Moersdorf, Philipp
    Histing, Tina
    Pohlemann, Tim
    Herath, Steven C.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (07): : 1329 - 1332
  • [8] Weight-bearing recommendations after operative fracture treatment-fact or fiction? Gait results with and feasibility of a dynamic, continuous pedobarography insole
    Braun, Benedikt J.
    Veith, Nils T.
    Rollmann, Mika
    Orth, Marcel
    Fritz, Tobias
    Herath, Steven C.
    Holstein, Jorg H.
    Pohlemann, Tim
    [J]. INTERNATIONAL ORTHOPAEDICS, 2017, 41 (08) : 1507 - 1512
  • [9] Braun BJ, 2021, FRONT SURG, P8
  • [10] Recovery of physical activity levels in adolescents after lower limb fractures: a longitudinal, accelerometry-based activity monitor study
    Ceroni, Dimitri
    Martin, Xavier
    Lamah, Leopold
    Delhumeau, Cecile
    Farpour-Lambert, Nathalie
    De Coulon, Geraldo
    Ferriere, Victor Dubois
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2012, 13