Effects of cryogenic cooling on the quality factor of lamb wave mode aluminium nitride piezoelectric-on-silicon MEMS resonators

被引:10
作者
Tu, C. [1 ]
Lee, J. E. -Y [1 ,2 ]
机构
[1] City Univ Hong Kong, Dept Elect Engn, Kowloon, Hong Kong, Peoples R China
[2] City Univ Hong Kong, State Key Lab Millimeter Waves, Hong Kong, Hong Kong, Peoples R China
关键词
Piezoelectric-on-silicon resonators; Cryogenic cooling; Anchor loss; Thermoelastic dissipation; THERMAL-EXPANSION; ALN; ANCHOR;
D O I
10.1016/j.sna.2016.04.011
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work investigates the temperature dependence of the quality factors (Q) of Aluminium Nitride (AlN) thin-film piezoelectric-on-silicon (TPoS) resonators as the devices are cryogenically cooled from room temperature to 78 K. Four designs of TPoS resonators with resonant frequencies in the range of 48 MHz to 142 MHz were considered. We found that in all but one of the resonators, Q appeared to be mostly constant in the measurement range of room temperature to 78 K. The only exception was a 90 mu m wide resonator vibrating at its fundamental mode at 48 MHz (referred to as Design A in this work). At room temperature, Design A at the fundamental mode had a Q substantially higher than another resonator of the same size but different support design (referred to as Design B in this work: 9500 compared to 2400). This notable difference in Q observed at room temperature due to differences in the support design corresponds well with differences in the trends of Q as a function of temperature when the designs were cryogenically cooled from room temperature to 78 K. More specifically, the Q of Design A doubled while Q of Design B was constant. Assuming that anchor loss as an energy loss mechanism is independent of temperature, the cryogenic cooling results thus further illustrate the dominance of anchor loss in Design B but not Design A at room temperature. Designs A and B were then excited at higher order modes (142 MHz) along with Designs C and D (100 MHz). Measured values of Q were much lower than Design A at the fundamental mode, and Q likewise did not increase with cryogenic cooling to 78 K. These experimental results taken as a whole illustrate the usefulness of cryogenic cooling as a practical approach to ascertain the dominance of temperature-independent energy losses (e.g. anchor loss) in TPoS resonators at room temperature. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:15 / 23
页数:9
相关论文
共 28 条
[21]  
Tabrizian R, 2015, 2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), P981, DOI 10.1109/TRANSDUCERS.2015.7181089
[22]   A semi-analytical modeling approach for laterally-vibrating thin-film piezoelectric-on-silicon micromechanical resonators [J].
Tu, Cheng ;
Lee, Joshua E-Y .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2015, 25 (11)
[23]  
Volkov Y., 1976, Sov. J. Exp. Theor. Phys, V43, P1171
[24]  
Wei-Chang Li, 2009, 15th International Conference on Solid-State Sensors, Actuators and Microsystems. Transducers 2009, P1445, DOI 10.1109/SENSOR.2009.5285815
[25]  
Yen TT, 2013, PROC IEEE MICR ELECT, P114, DOI 10.1109/MEMSYS.2013.6474190
[26]   THERMAL-EXPANSION OF ALN, SAPPHIRE, AND SILICON [J].
YIM, WM ;
PAFF, RJ .
JOURNAL OF APPLIED PHYSICS, 1974, 45 (03) :1456-1457
[27]   Simultaneous measurement of Young's modulus, Poisson ratio, and coefficient of thermal expansion of thin films on substrates [J].
Zhao, JH ;
Du, Y ;
Morgen, M ;
Ho, PS .
JOURNAL OF APPLIED PHYSICS, 2000, 87 (03) :1575-1577
[28]  
Zhu HS, 2015, PROC IEEE MICR ELECT, P797, DOI 10.1109/MEMSYS.2015.7051079