A review of magnetic actuation systems and magnetically actuated guidewire- and catheter-based microrobots for vascular interventions

被引:137
作者
Hwang, Junsun [1 ]
Kim, Jin-young [1 ,2 ]
Choi, Hongsoo [1 ,2 ,3 ]
机构
[1] DGIST, DGIST ETH Microrobot Res Ctr, Daegu 42988, South Korea
[2] DGIST, Dept Robot Engn, Daegu 42988, South Korea
[3] DGIST, Robot Res Ctr, Daegu 42988, South Korea
关键词
Magnetic actuation; Microrobots; Catheters; Guidewires; Interventions; PERCUTANEOUS CORONARY INTERVENTION; NAVIGATION SYSTEM; RADIATION-EXPOSURE; INITIAL-EXPERIENCE; ABLATION; FABRICATION; HEART; ELECTROPHYSIOLOGY; MANIPULATION; ANGIOPLASTY;
D O I
10.1007/s11370-020-00311-0
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Magnetic actuation techniques and microrobots have attracted considerable interest due to their potential applications in biomedicine. Interventional techniques have emerged as a minimally invasive approach to treat a wide range of vascular diseases. The current practice of interventional procedures is, however, limited by manual control of interventional devices and time-consuming procedures. Moreover, fluoroscopy is considered as an essential part of the procedure today despite posing many limitations for patients and physicians. Recently, various microrobotic solutions have been proposed for vascular interventions, including advances in magnetic navigation systems and magnetically steerable catheters and guidewires, which have shown potential benefits such as reduced radiation doses, improved access to difficult-to-reach and tortuous anatomy. This paper reviews the commercial magnetic actuation systems and magnetically actuated interventional microrobots that have been developed by academic research groups and medical companies worldwide, outlining their capability, applicability as well as limitations. We further address the challenges and future prospects of the research toward clinical acceptance of magnetic interventional technologies.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 105 条
[11]   Mobile microrobots for bioengineering applications [J].
Ceylan, Hakan ;
Giltinan, Joshua ;
Kozielski, Kristen ;
Sitti, Metin .
LAB ON A CHIP, 2017, 17 (10) :1705-1724
[12]  
Charreyron Samuel L., 2017, 2017 IEEE International Conference on Robotics and Automation (ICRA), P4843, DOI 10.1109/ICRA.2017.7989563
[13]   Design and Evaluation of a Steerable Magnetic Sheath for Cardiac Ablations [J].
Chautems C. ;
Lyttle S. ;
Boehler Q. ;
Nelson B.J. .
IEEE Robotics and Automation Letters, 2018, 3 (03) :2123-2128
[14]  
Chautems Christophe, 2017, 2017 IEEE International Conference on Robotics and Automation (ICRA), P4837, DOI 10.1109/ICRA.2017.7989562
[15]  
Chautems C, 2019, ADV INTELLIGENT SYST
[16]  
Chautems C, 2017, IEEE INT C INT ROBOT, P181, DOI 10.1109/IROS.2017.8202155
[17]   Magnetically powered microrobots: a medical revolution underway? [J].
Chautems, Christophe ;
Zeydan, Burak ;
Charreyron, Samuel ;
Chatzipirpiridis, George ;
Pane, Salvador ;
Nelson, Bradley J. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 51 (03) :405-407
[18]   Comparison of Magnetic Navigation System and Conventional Method in Catheter Ablation of Atrial Fibrillation: Is Magnetic Navigation System Is More Effective and Safer Than Conventional Method? [J].
Choi, Min Seok ;
Oh, Yong-Seog ;
Jang, Sung Won ;
Kim, Ji Hoon ;
Shin, Woo Seung ;
Youn, Ho-Joong ;
Jung, Wook Sung ;
Lee, Man Young ;
Seong, Ki Bae .
KOREAN CIRCULATION JOURNAL, 2011, 41 (05) :248-252
[19]   Remote-controlled catheter ablation of accessory pathways: results from the magnetic laboratory [J].
Chun, Julian Kyoung-Ryul ;
Ernst, Sabine ;
Matthews, Shibu ;
Schmidt, Boris ;
Bansch, Dietmar ;
Boczor, Sigrid ;
Ujeyl, Amaar ;
Antz, Matthias ;
Ouyang, Feifan ;
Kuck, Karl-Heinz .
EUROPEAN HEART JOURNAL, 2007, 28 (02) :190-195
[20]   Anatomy of the pig heart: comparisons with normal human cardiac structure [J].
Crick, SJ ;
Sheppard, MN ;
Ho, SY ;
Gepstein, L ;
Anderson, RH .
JOURNAL OF ANATOMY, 1998, 193 :105-119