A review of magnetic actuation systems and magnetically actuated guidewire- and catheter-based microrobots for vascular interventions

被引:135
作者
Hwang, Junsun [1 ]
Kim, Jin-young [1 ,2 ]
Choi, Hongsoo [1 ,2 ,3 ]
机构
[1] DGIST, DGIST ETH Microrobot Res Ctr, Daegu 42988, South Korea
[2] DGIST, Dept Robot Engn, Daegu 42988, South Korea
[3] DGIST, Robot Res Ctr, Daegu 42988, South Korea
关键词
Magnetic actuation; Microrobots; Catheters; Guidewires; Interventions; PERCUTANEOUS CORONARY INTERVENTION; NAVIGATION SYSTEM; RADIATION-EXPOSURE; INITIAL-EXPERIENCE; ABLATION; FABRICATION; HEART; ELECTROPHYSIOLOGY; MANIPULATION; ANGIOPLASTY;
D O I
10.1007/s11370-020-00311-0
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Magnetic actuation techniques and microrobots have attracted considerable interest due to their potential applications in biomedicine. Interventional techniques have emerged as a minimally invasive approach to treat a wide range of vascular diseases. The current practice of interventional procedures is, however, limited by manual control of interventional devices and time-consuming procedures. Moreover, fluoroscopy is considered as an essential part of the procedure today despite posing many limitations for patients and physicians. Recently, various microrobotic solutions have been proposed for vascular interventions, including advances in magnetic navigation systems and magnetically steerable catheters and guidewires, which have shown potential benefits such as reduced radiation doses, improved access to difficult-to-reach and tortuous anatomy. This paper reviews the commercial magnetic actuation systems and magnetically actuated interventional microrobots that have been developed by academic research groups and medical companies worldwide, outlining their capability, applicability as well as limitations. We further address the challenges and future prospects of the research toward clinical acceptance of magnetic interventional technologies.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 105 条
[1]   Soft erythrocyte-based bacterial microswimmers for cargo delivery [J].
Alapan, Yunus ;
Yasa, Oncay ;
Schauer, Oliver ;
Giltinan, Joshua ;
Tabak, Ahmet F. ;
Sourjik, Victor ;
Sitti, Metin .
SCIENCE ROBOTICS, 2018, 3 (17)
[2]   Procedural complications following diagnostic coronary angiography are related to the operator's experience and the catheter size [J].
Ammann, P ;
Brunner-La Rocca, HP ;
Angehrn, W ;
Roelli, H ;
Sagmeister, M ;
Rickli, H .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 59 (01) :13-18
[3]  
[Anonymous], 2001, PERMANENT MAGNET ELE
[4]   Accurate and reproducible target navigation with the Stereotaxis Niobe® Magnetic Navigation System [J].
Armacost, Michelle P. ;
Adair, Janet ;
Munger, Torrey ;
Viswanathan, Raju R. ;
Creighton, Francis M. ;
Curd, David T. ;
Sehra, Ruchir .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 :S26-S31
[5]   Initial experience with a magnetic navigation system for percutaneous coronary intervention in complex coronary artery lesions [J].
Atmakuri, SR ;
Lev, EI ;
Alviar, C ;
Ibarra, E ;
Raizner, AE ;
Solomon, SL ;
Kleiman, NS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (03) :515-521
[6]   Bacterial flagella-based propulsion and on/off motion control of microscale objects [J].
Behkam, Bahareh ;
Sitti, Metin .
APPLIED PHYSICS LETTERS, 2007, 90 (02)
[7]   Diet, obesity, and cardiovascular risk [J].
Bonow, RO ;
Eckel, RH .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (21) :2057-2058
[8]  
Bonvilain A, 2003, IEEE INT CONF ROBOT, P2960
[9]  
Boskma KJ, 2016, P IEEE RAS-EMBS INT, P61, DOI 10.1109/BIOROB.2016.7523599
[10]   Stereotaxis Niobe® magnetic navigation system for endocardial catheter ablation and gastrointestinal capsule endoscopy [J].
Carpi, Federico ;
Pappone, Carlo .
EXPERT REVIEW OF MEDICAL DEVICES, 2009, 6 (05) :487-498