Multi-layer polymer metal laminates for the fire protection of lightweight structures

被引:40
作者
Christke, S. [1 ]
Gibson, A. G. [1 ]
Grigoriou, K. [2 ]
Mouritz, A. P. [2 ]
机构
[1] Newcastle Univ, Ctr Composite Mat Engn, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
[2] RMIT Univ, Sir Lawrence Wackett Aerosp Res Ctr, Sch Aerosp Mech & Mfg Engn, GPO Box 2476, Melbourne, Vic 3001, Australia
基金
欧盟第七框架计划;
关键词
Fire protection; Multi-layer laminate; Composites; CFRP; Aluminium; Structural survivability; MECHANICAL-PROPERTIES; HIGH-TEMPERATURE; STEEL S460N; BEHAVIOR; MODEL; DETERIORATION; PERFORMANCE; FAILURE;
D O I
10.1016/j.matdes.2016.02.105
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A multi-layer polymer metal laminate (PML) system is described, which can be used to thermally insulate lightweight structural materials, such as aluminium or carbon fibre reinforced plastic (CFRP) composite, when exposed to fire. The system comprises many thin adhesively-bonded metal foils, bonded directly to the structural substrate. When exposed to fire the PML adhesive thermally decomposes with the generation of volatiles, causing the foils to delaminate and inflate, thus greatly reducing its thermal conductivity. The expanded PML slows heat transfer from the fire into the structural substrate, resulting in lower temperatures and increased structural survivability. The fire protection effects of two different thicknesses of PML are demonstrated here for both aluminium and CFRP substrates. Fire exposure tests demonstrate that the substrate temperatures are reduced and the time to failure under load is substantially improved. The protection offered is equivalent or superior to conventional fire protection materials such as ceramic fibre mat or intumescent coatings. The advantage of the PML is that, in non-fire conditions, it contributes to the appearance and load-bearing capability of the structure without being prone to damage or water absorption. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:349 / 356
页数:8
相关论文
共 36 条
[1]  
Brown J.R., 1995, J FIRE SCI, V19, P109
[2]   Toward aerogel based thermal superinsulation in buildings: A comprehensive review [J].
Cuce, Erdem ;
Cuce, Pinar Mert ;
Wood, Christopher J. ;
Riffat, Saffa B. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 34 :273-299
[3]   Expandable graphite: a fire retardant additive for polyurethane coatings [J].
Duquesne, S ;
Le Bras, M ;
Bourbigot, S ;
Delobel, R ;
Vezin, H ;
Camino, G ;
Eling, B ;
Lindsay, C ;
Roels, T .
FIRE AND MATERIALS, 2003, 27 (03) :103-117
[4]   Modelling the tension and compression strengths of polymer laminates in fire [J].
Feih, S. ;
Mathys, Z. ;
Gibson, A. G. ;
Mouritz, A. P. .
COMPOSITES SCIENCE AND TECHNOLOGY, 2007, 67 (3-4) :551-564
[5]   Structural Analysis of Compression Deformation and Failure of Aluminum in Fire [J].
Feih, S. ;
Kandare, E. ;
Lattimer, B. Y. ;
Mouritz, A. P. .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2011, 137 (07) :728-738
[6]   Compression load failure of aluminum plates due to fire [J].
Fogle, Emily J. ;
Lattimer, Brian Y. ;
Feih, Stefanie ;
Kandare, Everson ;
Mouritz, Adrian P. ;
Case, Scott W. .
ENGINEERING STRUCTURES, 2012, 34 :155-162
[7]   Carbon nanotube buckypaper to improve fire retardancy of high-temperature/high-performance polymer composites [J].
Fu, Xiang ;
Zhang, Chuck ;
Liu, Tao ;
Liang, Richard ;
Wang, Ben .
NANOTECHNOLOGY, 2010, 21 (23)
[8]  
Giancaspro J, 2004, SAMPE J, V40, P42
[9]   Modeling composite high temperature behavior and fire response under load [J].
Gibson, A. G. ;
Browne, T. N. A. ;
Feih, S. ;
Mouritz, A. P. .
JOURNAL OF COMPOSITE MATERIALS, 2012, 46 (16) :2005-2022
[10]   A MODEL FOR THE THERMAL PERFORMANCE OF THICK COMPOSITE LAMINATES IN HYDROCARBON FIRES [J].
GIBSON, AG ;
WU, YS ;
CHANDLER, HW ;
WILCOX, JAD ;
BETTESS, P .
REVUE DE L INSTITUT FRANCAIS DU PETROLE, 1995, 50 (01) :69-74